Samsung AR36HPFUAWKNMG, AR36HCFUAWKNMG, AR30HPFUAWKNMG, AR30HCFUAWKNMG manual BasicAA function

Page 10

BasicAA function

Basic operation is an operation mode that can be selected by pressing the Mode button.

Auto

In Auto mode, the air conditioner will automatically set the temperature and fan speed depending on the room temperature detected by the room temperature.

Cool

In Cool mode, the air conditioner will cool your room. You can adjust the temperature and the fan speed to feel cooler in hot season.

If current outside temperatures are much higher than the selected indoor temperature, it may take time to bring the inner temperature to the desired coolness.

Dry

The air conditioner in Dry mode acts like a dehumidifier by removing moisture from the indoor air. Dry mode makes the air feel refreshing in a humid climate.

Fan

Fan mode can be selected to ventilate your room. Fan mode will be helpful to refresh the stale air in your room.

Heat (ARHPseries)

The air conditioner heats as well as cools. Warm your room with this versatile appliance in the cold of winter.

Fan may not operate for about 3~5 minutes at the beginning to prevent any cold blasts while the air conditioner is warming up.

Since the air conditioner heats the room by taking heat energy from outdoor air, the heating capacity may decrease when outdoor temperature is extremely low.

Use an additional heating appliance in combination with the air conditioner if you feel the air conditioner heats insufficiently.

10

SSEC_UMG_IB&IM_DB68-04508A_EN.indd 10

2014-2-10 14:56:41

Image 10
Contents English Contents Follow directions SafetAA y precautionsImportant safety symbols and precautions Wall socketFor Using For Cleaning ChecAA king before use Operation rangesMain parts ChecAA king the name of the partsDisplay ChecAA king the remote controller Remote controller buttonsStoring the remote controller Remote controller displayBattery changing time Inserting the batteriesBasicAA function Press the button to adjust the temperature Press the button to set the desired fan speedAdjusA ting the air flow direction Using the Turbo functionPress the Air swing button on the remote controller Vertical air flowPress the Time Up or Time Down button to set the time AA modePress the button on the remote controller Press the Set button to active it onAdditional options available in On timer mode SettinAA g the On/Off timerPress the On Timer/Off Timer button You can select from Auto/Cool/Dry/Fan/Heat ARHPmodelIf the air conditioner is on If the air conditioner is off Using the Smart Saver functionFrom the moment you have set the timer Turn off automaticallyUsing the Quiet function UsingAA the Auto Clean functionWhen the air conditioner is turned on Opening the panel Cleaning the indoor unitCleaning the outdoor unit heat exchanger Heat exchangerRemoving the Air filter CleanAA ing the air conditionerCleaning the air filter Open the panel and put the Air filter outMaintAA aining the air conditioner Periodical checksTroubAA leshooting Flow movement changes. It is normal ConnectionSafety precautions General informationPower supply line, fuse or circuit breaker Choosing the installation locationInstalling the unit  a place where the air filter can be replaced easilyWhere sulfide gas exists ChooAA sing the installation locationOutdoor Unit  Figure Description When installing more than 1 outdoor unitWhen the air outlet is towards the wall Top view Side viewAccessories in the indoor unit case AccessoriesAccessories in the outdoor unit case Tools required for installation General Tools Fixing the installation plateOptional accessories Tools for test operationsCable specification Connecting the assembly cableConnecting the cable Each wire is labeled with the corresponding terminal number Extend the assembly cable if necessaryInstallation Smooth the cut edges Cut off the remaining foam insulationUnscrew the caps at the end of each pipe AAPurging the indoor unitCutting or extending the pipe Put a flare nut slightly into the pipe and modify the flareCuttingAA or extending the pipe Outer DiameterHose tight Drain hose installationTwo hoses are firmly connected, there is no water leakage Check for leakage on both side of the drain outletPurging the connected pipes ARHPseries30g of refrigerant R-22 must be added for each extra meter Adding RefrigerantAdd refrigerant charge according to table below If you use a pipe shorter than 4 mPerfoAA rming the gas leak tests Fixing the indoor unit in placeFixing the outdoor unit in place Outdoor unit installed on the wall by rackAppropriate support wall or ground FinalAA Check and Trial Operation Press the Power button and check the followingPress the Power button to stop the operation Check the followingsAfter tube contraction work is completed, wrap it with Apply heat to the contraction tube to contract itInsulation tape to finish TechnAA ical Specifications AR30HCFUAWK/MG AR36HCFUAWK/MGEnglish Questions or COMMENTS? EgyptAir Conditioner
Related manuals