Samsung AR12KRFNEWKNMG, AR24KQFNRWKNMG, AR24MQFNRWKNMG Drilling a hole through the wall, Tools

Page 37

Installation

Accessories in the outdoor unit package

Rubber leg (4)

NOTE

A flare nut is attached to the end of each pipe of an evaporator or a service port. Use flare nuts when connecting the pipes.

Wire assembly cables are optional. If they are not supplied, use standard cables.

The drain plug and the rubber legs are included only when the air conditioner is supplied without assembly pipes.

If these accessories are supplied, they are in the accessory package or outdoor unit package.

Tools

General tools

Vacuum pump

(Backward flowing prevention)

Manifold gauge

Stud finder

Torque wrench

Pipe cutter

Reamer

Pipe bender

Spirit level

Screwdriver

Spanner

Drill

L-wrench

Measuring tape

Tools for test operation

Thermometer

Resistance meter

Electroscope

Step 1.4 Drilling a hole through the wall

Before fixing the installation plate to a wall and then fixing the indoor unit to the installation plate, a window frame, or a gypsum board, you must determine the position of a hole (with 65 mm inner diameter) through which the pipe bundle (consisting of power and communication cables, refrigerant pipes, and drain hose) will pass and then drill that hole.

1Determine the position of a 65 mm hole in consideration of the possible directions of the pipe bundle and the minimum distances between the hole and the installation plate.

Left

Right

 

Rear right or left

Bottom right

<Possible directions of the pipe bundle>

CAUTION

If changing the pipe direction from left to right, do not drastically bent it but slowly turn it in the opposite direction as shown. Otherwise, the pipe may be damaged in the process.

Pipe bundle hole

<Minimum distances between the hole and the

installation plate>

 

 

 

 

(Unit : mm)

 

 

 

 

 

 

Model

A

B

C

 

D

 

 

 

 

 

 

✴✴12KR✴✴

36

120

81

 

36

 

 

 

 

 

 

✴✴12KQ✴✴

36

190

81

 

36

 

 

 

 

 

 

✴✴18/24✴✴

33

110

110

 

33

 

 

 

 

 

 

 

Pipe bundle hole: Ø 65 mm

36English

Image 37
Contents Samsung DB68-06042A-02 AirconditionerContents Correct Disposal of This Product Failing to do so may result in electric shock or fire Safety InformationThis may result in electric shock or fire For Power Supply This may result in electric shock Do not touch the circuit breakerwith wet handsThis may result in electric shock or burns This may result in children seriously injuring themselvesDo not operate the appliance with wet hands Do not place objects or devices under the indoor unitDo not drink the water from the air conditioner Do not touch the pipes connected with the productDo not clean the inside of the air conditioner by yourself For CleaningSingle user indicator Operation indicatorIndoor Unit Overview DisplayInserting batteries Remote Control OverviewControlling temperature Remote Control OperationOperation modes Vertical air flow Controlling air flow directionHorizontal air flow manual Cooling Operation Cool modeStep cooling function Dehumidifying Operation Dry modeMode is running Heat modeHeating Operation Is running The blade looks almost closedAuto mode Quick Smart FeaturesFan mode Fast function Select Beep Comfort functionEnergy-Saving Operation Cool mode When the Single user function starts,Single user function Timed on/Timed off function Good’sleep function Default operation time for the good’sleep functionRunning Auto clean Cleaning at a GlanceDo not clean the display by using alkaline detergent Cleaning the filter Troubleshooting To pass the error code to the service centre Check whether the drains are clean. Clean them regularlyDoes not work Electric wavesTechnical Specifications 27˚C 20000 Btu/h AR18MQFNEWK/MG AR24MRFNEWK/MG AR24MQFNRWK/MG Installation of the unit Safety Information on InstallationGeneral information Install the unit in a place where water can drain smoothly Power supply line, fuse, or circuit breakerPreparation Choosing the installation locationMinimum clearances for the outdoor unit 5cases Packing and UnpackingUnit mm Indoor unitAccessories in the indoor unit package Checking and preparing accessories and tools AccessoriesOptional accessories Tools Drilling a hole through the wallTaping the pipes, cables, and drain hose Disassembling the installation Indoor Unit InstallationDisassembling the cover panel PlateCircular terminal Connecting the cables assembly cableCompression dimension should be Optional Extending the power cablePrepare the following tools Apply heat to the contraction tube to contract itPressing socket Incomplete wire Installing and connecting the drain hoseInstall the drain hose Optional Extending the drain hoseOptional Changing the direction of the drain hose Depth a Shortening or extending the refrigerant pipes assembly pipeWhen fixing the indoor unit on a wall 10 Fixing the installation plateWhen fixing the indoor unit on a window frame When fixing the indoor unit on a gypsum board 11 Fixing the indoor unit to the installation plateFix the installation plate without inclining to one side 12 Assembling the cover panelConnecting the cables and the refrigerant pipes Outdoor Unit InstallationFixing the outdoor unit in place Optional Fixing the outdoor unit to a wall with a rackEvacuating the air Leave the system in the standby modeCooling capacity and malfunction. Use a vacuum pump Siphon Adding refrigerantPerforming the gas leak tests Running the Smart Install modeError Error indicatorBlocking error Open Appears when anTurn on th air conditioner and select Fast Cool mode Check the following Strength of the installation sitePerforming final check and trial operation Pumping down refrigerantEnglish English English