Samsung AR24MRFNEWKNMG manual Performing final check and trial operation, Pumping down refrigerant

Page 52

Step 4.3 Performing final check and trial operation

1Check the following:

Strength of the installation site

Tightness of pipe connection to detect gas leak

Electric wiring connection

Heat-resistant insulation of the pipe

Drainage

Grounding conductor connection

Correct operation (Take the following steps.)

2Press the (Power) button on the remote control to check the following:

The indicator on the indoor unit lights up.

The airflow blade opens and the fan gears up for operation.

3Press the (Mode) button to select Cool or Heat mode. Then take the following sub-steps:

In Cool mode, use the Temperature button to set the set temperature to 16 °C.

In Heat mode, use the Temperature button to set the set temperature to 30 °C.

Check whether, approximately 3 to 5 minutes later, the outdoor unit starts, and a cool or warm air blows out.

After12 minutes of stationary condition, check the indoor unit air treatment.

4Press the (Air swing) button to check whether the airflow blades work properly.

5Press the (Power) button to stop the trial operation.

Pumping down refrigerant

Pump-down is an operation intended to collect all the system refrigerant in the outdoor unit. This operation must be carried out before disconnecting the refrigerant tubing in order to avoid refrigerant loss to the atmosphere.

1Shut off the liquid valve with the Allen wrench.

2Turn on the air conditioner in cooling with fan operating at high velocity. (Compressor will immediately start, provided 3 minutes have elapsed since the last stop.)

3After 2 minutes of operation, shut the suction valve with the same wrench.

4Turn off the air conditioner and switch mains supply off.

5Disconnect tubing. After disconnection, protect valves and tubing ends from dust.

CAUTION

Compressor damage may occur if the compressor is run at a negative suction pressure.

Pumping down for removing the product

1Turn on th air conditioner and select Fast Cool mode.

2Let the compressor run for more than 5 minutes. If the compressor does not operate for more than 5 minutes due to protection control, wait about 2 minutes, and then carry out the next procedure.

3Release the valve caps on High and Low pressure side.

4Use L-wrench to close the valve on the high pressure side.

5After approximately 1 minute, close the valve on the low pressure side.

6Stop operation of the air conditioner by pressing the (Power) button on the indoor unit or remote control.

7Disconnect the pipes.

 

1

 

1 minute

Liquid service port

Gas service port

<High pressure>

<Low pressure>

2

Off

Installation

English 51

Image 52
Contents Samsung Airconditioner DB68-06042A-02Contents Correct Disposal of This Product Failing to do so may result in electric shock or fire Safety InformationThis may result in electric shock or fire For Power Supply Do not touch the circuit breakerwith wet hands This may result in electric shockThis may result in electric shock or burns This may result in children seriously injuring themselvesDo not place objects or devices under the indoor unit Do not operate the appliance with wet handsDo not drink the water from the air conditioner Do not touch the pipes connected with the productFor Cleaning Do not clean the inside of the air conditioner by yourselfOperation indicator Single user indicatorIndoor Unit Overview DisplayRemote Control Overview Inserting batteriesControlling temperature Remote Control OperationOperation modes Vertical air flow Controlling air flow directionHorizontal air flow manual Cooling Operation Cool modeStep cooling function Dry mode Dehumidifying OperationHeat mode Mode is runningHeating Operation Is running The blade looks almost closedAuto mode Quick Smart FeaturesFan mode Fast function Comfort function Select BeepEnergy-Saving Operation Cool mode When the Single user function starts,Single user function Timed on/Timed off function Default operation time for the good’sleep function Good’sleep functionRunning Auto clean Cleaning at a GlanceDo not clean the display by using alkaline detergent Cleaning the filter Troubleshooting Check whether the drains are clean. Clean them regularly To pass the error code to the service centreDoes not work Electric wavesTechnical Specifications 27˚C 20000 Btu/h AR18MQFNEWK/MG AR24MRFNEWK/MG AR24MQFNRWK/MG Installation of the unit Safety Information on InstallationGeneral information Power supply line, fuse, or circuit breaker Install the unit in a place where water can drain smoothlyPreparation Choosing the installation locationMinimum clearances for the outdoor unit Packing and Unpacking 5casesUnit mm Indoor unitAccessories in the indoor unit package Checking and preparing accessories and tools AccessoriesOptional accessories Drilling a hole through the wall ToolsTaping the pipes, cables, and drain hose Indoor Unit Installation Disassembling the installationDisassembling the cover panel PlateConnecting the cables assembly cable Circular terminalOptional Extending the power cable Compression dimension should bePrepare the following tools Apply heat to the contraction tube to contract itInstalling and connecting the drain hose Pressing socket Incomplete wireInstall the drain hose Optional Extending the drain hoseOptional Changing the direction of the drain hose Shortening or extending the refrigerant pipes assembly pipe Depth aWhen fixing the indoor unit on a wall 10 Fixing the installation plateWhen fixing the indoor unit on a window frame 11 Fixing the indoor unit to the installation plate When fixing the indoor unit on a gypsum boardFix the installation plate without inclining to one side 12 Assembling the cover panelOutdoor Unit Installation Connecting the cables and the refrigerant pipesFixing the outdoor unit in place Optional Fixing the outdoor unit to a wall with a rackEvacuating the air Leave the system in the standby modeCooling capacity and malfunction. Use a vacuum pump Adding refrigerant SiphonRunning the Smart Install mode Performing the gas leak testsError indicator ErrorBlocking error Open Appears when anCheck the following Strength of the installation site Turn on th air conditioner and select Fast Cool modePerforming final check and trial operation Pumping down refrigerantEnglish English English