Samsung AR24MRFNEWK/MG Safety Information, Failing to do so may result in electric shock or fire

Page 5

Safety Information

Safety Information

Before using your new air conditioner, please read this manual thoroughly to ensure that you know how to safely and efficiently operate the extensive features and functions of your new appliance.

Because the following operating instructions cover various models, the characteristics of your air conditioner may differ slightly from those described in this manual. If you have any questions, call your nearest contact centre or find help and information online at www.samsung.com.

WARNING

Hazards or unsafe practices that may result in severe personal injury or death.

CAUTION

Hazards or unsafe practices that may result in minor personal injury or property damage.

Follow directions.

Do NOT attempt.

Make sure the machine is grounded to prevent electric shock.

Cut off the power supply.

Do NOT disassemble.

FOR INSTALLATION

WARNING

Use a power cord with this product's power specifications or higher and use the power cord for this appliance only. In addition, do not use an extension cord.

Extending the power cord may result in electric shock or fire.

Do not use an electric transformer. This may result in electric shock or fire.

If the voltage/frequency/rated current condition is different, it may cause fire.

The installation of this appliance must be performed by a qualified technician or service company.

Failing to do so may result in electric shock, fire, explosion, problems with the product, or injury and may also void warranty on the installed product.

Install an Isolation Switch next to the Air Conditioner (but not on the panels of the Air Conditioner) and circuit breaker dedicated to the air conditioner.

Failing to do so may result in electric shock or fire.

Fix the outdoor unit firmly so that the electric part of the outdoor unit is not exposed.

Failing to do so may result in electric shock, fire, explosion, or problems with the product.

Do not install this appliance near a heater, or inflammable material. Do not install this appliance in a humid, oily or dusty location, in a location exposed to direct sunlight and water (or rain). Do not install this appliance in a location where gas may leak.

This may result in electric shock or fire.

Never install the outdoor unit in a location such as on a high external wall where it could fall.

4English

Image 5
Contents Samsung DB68-06042A-02 AirconditionerContents Correct Disposal of This Product This may result in electric shock or fire Safety InformationFailing to do so may result in electric shock or fire For Power Supply This may result in electric shock Do not touch the circuit breakerwith wet handsThis may result in electric shock or burns This may result in children seriously injuring themselvesDo not operate the appliance with wet hands Do not place objects or devices under the indoor unitDo not drink the water from the air conditioner Do not touch the pipes connected with the productDo not clean the inside of the air conditioner by yourself For CleaningSingle user indicator Operation indicatorIndoor Unit Overview DisplayInserting batteries Remote Control OverviewOperation modes Remote Control OperationControlling temperature Horizontal air flow manual Controlling air flow directionVertical air flow Step cooling function Cool modeCooling Operation Dehumidifying Operation Dry modeMode is running Heat modeHeating Operation Is running The blade looks almost closedFan mode Quick Smart FeaturesAuto mode Fast function Select Beep Comfort functionSingle user function Cool mode When the Single user function starts,Energy-Saving Operation Timed on/Timed off function Good’sleep function Default operation time for the good’sleep functionDo not clean the display by using alkaline detergent Cleaning at a GlanceRunning Auto clean Cleaning the filter Troubleshooting To pass the error code to the service centre Check whether the drains are clean. Clean them regularlyDoes not work Electric wavesTechnical Specifications 27˚C 20000 Btu/h AR18MQFNEWK/MG AR24MRFNEWK/MG AR24MQFNRWK/MG General information Safety Information on InstallationInstallation of the unit Install the unit in a place where water can drain smoothly Power supply line, fuse, or circuit breakerMinimum clearances for the outdoor unit Choosing the installation locationPreparation 5cases Packing and UnpackingUnit mm Indoor unitOptional accessories Checking and preparing accessories and tools AccessoriesAccessories in the indoor unit package Tools Drilling a hole through the wallTaping the pipes, cables, and drain hose Disassembling the installation Indoor Unit InstallationDisassembling the cover panel PlateCircular terminal Connecting the cables assembly cableCompression dimension should be Optional Extending the power cablePrepare the following tools Apply heat to the contraction tube to contract itPressing socket Incomplete wire Installing and connecting the drain hoseInstall the drain hose Optional Extending the drain hoseOptional Changing the direction of the drain hose Depth a Shortening or extending the refrigerant pipes assembly pipeWhen fixing the indoor unit on a window frame 10 Fixing the installation plateWhen fixing the indoor unit on a wall When fixing the indoor unit on a gypsum board 11 Fixing the indoor unit to the installation plateFix the installation plate without inclining to one side 12 Assembling the cover panelConnecting the cables and the refrigerant pipes Outdoor Unit InstallationFixing the outdoor unit in place Optional Fixing the outdoor unit to a wall with a rackCooling capacity and malfunction. Use a vacuum pump Leave the system in the standby modeEvacuating the air Siphon Adding refrigerantPerforming the gas leak tests Running the Smart Install modeError Error indicatorBlocking error Open Appears when anTurn on th air conditioner and select Fast Cool mode Check the following Strength of the installation sitePerforming final check and trial operation Pumping down refrigerantEnglish English English