If the outdoor unit falls, it may result in injury, death or property damage.

This appliance must be properly grounded. Do not ground the appliance to a gas pipe, plastic water pipe, or telephone line.

Failing to do so may result in electric shock, fire, and explosion.

Make sure to use a socket-outlet with ground.

CAUTION

Install your appliance on a level and hard floor that can support its weight.

Failing to do so may result in abnormal vibrations, noise, or problems with the product.

Install the drain hose properly so that water drains correctly.

Failing to do so may result in water overflowing and property damage. Avoid adding drain to waste pipes as odours may arise in the future.

When installing the outdoor unit, make sure to connect the drain hose so that draining is performed correctly.

The water generated during heating by the outdoor unit may overflow and result in property damage.

In particular, in winter, if a block of ice falls, it may result in injury, death or property damage.

FOR POWER SUPPLY

WARNING

When the circuit breaker is damaged, contact your nearest service centre.

Do not pull or excessively bend the power line. Do not twist or tie the power line. Do not hook the power line over a metal object, place a heavy object on the power line, insert the power line between objects, or push the power line into the space behind the appliance.

This may result in electric shock or fire.

CAUTION

When not using the air conditioner for a long period of time or during a thunder/lightning storm, cut the power at the circuit breaker.

Failing to do so may result in electric shock or fire.

FOR USING

WARNING

If the appliance is flooded, please contact your nearest service centre.

Failing to do so may result in electric shock or fire.

Safety Information

English 5

Image 6
Contents Samsung Airconditioner DB68-06042A-02Contents Correct Disposal of This Product Safety Information Failing to do so may result in electric shock or fireThis may result in electric shock or fire For Power Supply This may result in electric shock or burns Do not touch the circuit breakerwith wet handsThis may result in electric shock This may result in children seriously injuring themselvesDo not drink the water from the air conditioner Do not place objects or devices under the indoor unitDo not operate the appliance with wet hands Do not touch the pipes connected with the productFor Cleaning Do not clean the inside of the air conditioner by yourselfIndoor Unit Overview Operation indicatorSingle user indicator DisplayRemote Control Overview Inserting batteriesRemote Control Operation Controlling temperatureOperation modes Controlling air flow direction Vertical air flowHorizontal air flow manual Cool mode Cooling OperationStep cooling function Dry mode Dehumidifying OperationHeating Operation Heat modeMode is running Is running The blade looks almost closedQuick Smart Features Auto modeFan mode Fast function Comfort function Select BeepCool mode When the Single user function starts, Energy-Saving OperationSingle user function Timed on/Timed off function Default operation time for the good’sleep function Good’sleep functionCleaning at a Glance Running Auto cleanDo not clean the display by using alkaline detergent Cleaning the filter Troubleshooting Does not work Check whether the drains are clean. Clean them regularlyTo pass the error code to the service centre Electric wavesTechnical Specifications 27˚C 20000 Btu/h AR18MQFNEWK/MG AR24MRFNEWK/MG AR24MQFNRWK/MG Safety Information on Installation Installation of the unitGeneral information Power supply line, fuse, or circuit breaker Install the unit in a place where water can drain smoothlyChoosing the installation location PreparationMinimum clearances for the outdoor unit Unit mm Packing and Unpacking5cases Indoor unitChecking and preparing accessories and tools Accessories Accessories in the indoor unit packageOptional accessories Drilling a hole through the wall ToolsTaping the pipes, cables, and drain hose Disassembling the cover panel Indoor Unit InstallationDisassembling the installation PlateConnecting the cables assembly cable Circular terminalPrepare the following tools Optional Extending the power cableCompression dimension should be Apply heat to the contraction tube to contract itInstall the drain hose Installing and connecting the drain hosePressing socket Incomplete wire Optional Extending the drain hoseOptional Changing the direction of the drain hose Shortening or extending the refrigerant pipes assembly pipe Depth a10 Fixing the installation plate When fixing the indoor unit on a wallWhen fixing the indoor unit on a window frame Fix the installation plate without inclining to one side 11 Fixing the indoor unit to the installation plateWhen fixing the indoor unit on a gypsum board 12 Assembling the cover panelFixing the outdoor unit in place Outdoor Unit InstallationConnecting the cables and the refrigerant pipes Optional Fixing the outdoor unit to a wall with a rackLeave the system in the standby mode Evacuating the airCooling capacity and malfunction. Use a vacuum pump Adding refrigerant SiphonRunning the Smart Install mode Performing the gas leak testsBlocking error Open Error indicatorError Appears when anPerforming final check and trial operation Check the following Strength of the installation siteTurn on th air conditioner and select Fast Cool mode Pumping down refrigerantEnglish English English