Adjusting the air flow direction

Air flow can be directed to your desired position.

Vertical air flow

Air flow blades move up and down.

Press the Vertical air swingbutton on the remote controller.

Air swing indicator will be on the remote controller display and air flow blades move up and down continuously to circulate the air.

Press the Vertical air swing button on the remote controller again, to keep the air flow direction in a constant position.

If you adjust the vertical air flow blade manually, it may not close completely when you turn off the air conditioner.

• Adjusting the air flow direction is not available in good'sleep mode while it is in

cool mode.

However, you can adjust the air flow direction in good'sleep mode while it is in heat mode.

02 Basic fun n iot

Horizontal air flow

Make sure one of the blade pin lever that stick out of the air flow blades are not broken.

Move the blade pin lever left or right to keep the air flow direction in a constant position you prefer.

• Be extremely careful with your fingers while adjusting the Horizontal air flow direction.

There is a potential risk of personal injury when the unit is mishandled.

Blade pin lever

English-17

MG_GOOD_A3050_IB&IM_EN_DB68-04069A-00.indd 17

11/09/2013 21:10:40

Image 17
Contents Air Conditioner Features of your new air conditioner Contents English-4 Safety precautions01epaPr n atio English-5English-6 For UsingEnglish-7 English-8 Do not place objects or devices under the indoor unitEnglish-9 For CleaningEnglish-10 Checking before useOperation ranges T05s In llan atio Technical SpecificationsEnglish-11 Main parts Checking the name of the partsDisplay English-12English-13 Checking the remote controllerRemote controller buttons Battery changing time Remote controller displayStoring the remote controller Inserting the batteriesBasic function English-16 Press the button to adjust the temperaturePress the button to set the desired fan speed Vertical air flow Adjusting the air flow directionHorizontal air flow English-17English-18 Using the Fast functionUsing the Comfort function English-19 When the air conditioner is on and in cool/heat modeMode English-20 Setting the On/Off timerPress the On Timer/Off Timer button Turn off automatically From the moment you have set the timerIf the air conditioner is on If the air conditioner is off English-22 Using the Auto Clean functionWhen the air conditioner is turned on Cleaning the outdoor unit heat exchanger Cleaning the air conditionerEnglish-23 Sre04 OthRemoving the Air filter Cleaning the air filterEnglish-24 Remove the air filter from the main bodyTop of the Air filter into the main body.. ➀ Reassembling the Air filterEnglish-25 English-26 Maintaining the air conditionerEnglish-27 TroubleshootingAir conditioner Check the Drains have been cleared Regular Maintenance Button or disconnect the power plug/switchError is indicated Heard when refrigerant flow movement changes. It is normalEnglish-29 General informationInstalling the unit Choosing the installation locationPower supply line, fuse or circuit breaker Indoor unitEnglish-31 Where sulfide gas existsOutdoor Unit When the air outlet is towards the wall When installing more than 1 outdoor unitEnglish-32  Figure DescriptionAccessories in the indoor unit case AccessoriesEnglish-33 LlanOptional accessories Accessories in the outdoor unit caseTools required for installation General Tools Tools for test operationsEnglish-35 Fixing the installation plateAssembling the hanger screw Removing the screws This QR code for detail video of indoor unit installationRemoving the Cover panel Before mounting the indoor unit English-36English-37 Assembling the Cover panel After mounting the indoor unitCable specification Connecting the assembly cableConnecting the cable English-38English-39 Extend the assembly cable if necessaryEach wire is labeled with the corresponding terminal number Smooth the cut edges English-40Cut off the remaining foam insulation TorqueCutting or extending the pipe Evacuating the indoor unitEnglish-41 Unscrew the caps at the end of each pipeDepth a English-42Put a flare nut slightly into the pipe and modify the flare English-43 Drain hose installationEnglish-44 Change the direction only when it is necessaryShield Downwards as seen in the pictureEnglish-45 Evacuating the connected pipesConnect a drain hose to the drain plug Drain hole Drain plugEnglish-46 Adding RefrigerantOuter Torque If you use a pipe longer than 5 mEnglish-47 Performing the gas leak testsFixing the outdoor unit in place Outdoor unit installed on the wall by rackEnglish-48 12HC 507 12HP 543 18HC 602English-49 Smart Install modeOff Blinking English-50English-51 Final check and trial operationEnglish-52 How to connect your extended power cablesApply heat to the contraction tube to contract it After tube contraction work is completed, wrap it withMGGOODA3050IB&IMENDB68-04069A-00.indd 11/09/2013 0211 Questions or COMMENTS?