Disassembling/Assembling the Cover panel for indoor unit installation

Please scan

this QR code for detail video of indoor unit installation..

In order to install the indoor unit, you must disassemble the cover panel first.. Please proceed following instructions to disassemble and assemble the cover panel.. Hooks (on the cover panel) may get damaged if you apply excessive force as you disassemble and assemble the cover panel.. Please follow the following instructions..

Removing the screws

Cover panel is assembled on the bottom part of the indoor unit (as shown in the illustration) and it is fastened with screws.. Remove the Cap screw first and unfasten the screws so that you can disassemble the cover panel..

Cap Screw

<Remove the Cap screw>

Cover Panel

<Unfasten the screw>

Removing the Cover panel (Before mounting the indoor unit)

Cover panel is fixed to a main body of the product with hooks on two sides and central part as shown in the illustration.. Release the hooks on the sides first, and then release the hooks on the central part..

Check the location of the hooks before removing the cover panel..

ffLocation of the hooks on the central part

Side part

Central part

Number and location of the hooks

Hook

For specific Hook location and quantity, please refer to cover panel with indicating arrows based on physical goods..

English-36

MG_GOOD_A3050_IB&IM_EN_DB68-04069A-00.indd 36

11/09/2013 21:11:10

Image 36
Contents Air Conditioner Features of your new air conditioner Contents Safety precautions English-4English-5 01epaPr n atioFor Using English-6English-7 Do not place objects or devices under the indoor unit English-8For Cleaning English-9Checking before use Operation rangesEnglish-10 Technical Specifications English-11T05s In llan atio Checking the name of the parts Main partsDisplay English-12Checking the remote controller Remote controller buttonsEnglish-13 Remote controller display Battery changing timeStoring the remote controller Inserting the batteriesBasic function Press the button to adjust the temperature Press the button to set the desired fan speedEnglish-16 Adjusting the air flow direction Vertical air flowHorizontal air flow English-17Using the Fast function Using the Comfort functionEnglish-18 When the air conditioner is on and in cool/heat mode ModeEnglish-19 Setting the On/Off timer Press the On Timer/Off Timer buttonEnglish-20 From the moment you have set the timer If the air conditioner is on If the air conditioner is offTurn off automatically Using the Auto Clean function When the air conditioner is turned onEnglish-22 Cleaning the air conditioner Cleaning the outdoor unit heat exchangerEnglish-23 Sre04 OthCleaning the air filter Removing the Air filterEnglish-24 Remove the air filter from the main bodyReassembling the Air filter English-25Top of the Air filter into the main body.. ➀ Maintaining the air conditioner English-26Troubleshooting Air conditionerEnglish-27 Button or disconnect the power plug/switch Check the Drains have been cleared Regular MaintenanceError is indicated Heard when refrigerant flow movement changes. It is normalGeneral information English-29Choosing the installation location Installing the unitPower supply line, fuse or circuit breaker Indoor unitWhere sulfide gas exists Outdoor UnitEnglish-31 When installing more than 1 outdoor unit When the air outlet is towards the wallEnglish-32  Figure DescriptionAccessories Accessories in the indoor unit caseEnglish-33 LlanAccessories in the outdoor unit case Optional accessoriesTools required for installation General Tools Tools for test operationsFixing the installation plate Assembling the hanger screwEnglish-35 This QR code for detail video of indoor unit installation Removing the screwsRemoving the Cover panel Before mounting the indoor unit English-36Assembling the Cover panel After mounting the indoor unit English-37Connecting the assembly cable Cable specificationConnecting the cable English-38Extend the assembly cable if necessary Each wire is labeled with the corresponding terminal numberEnglish-39 English-40 Smooth the cut edgesCut off the remaining foam insulation TorqueEvacuating the indoor unit Cutting or extending the pipeEnglish-41 Unscrew the caps at the end of each pipeEnglish-42 Put a flare nut slightly into the pipe and modify the flareDepth a Drain hose installation English-43Change the direction only when it is necessary English-44Shield Downwards as seen in the pictureEvacuating the connected pipes English-45Connect a drain hose to the drain plug Drain hole Drain plugAdding Refrigerant English-46Outer Torque If you use a pipe longer than 5 mPerforming the gas leak tests English-47Outdoor unit installed on the wall by rack Fixing the outdoor unit in placeEnglish-48 12HC 507 12HP 543 18HC 602Smart Install mode English-49English-50 Off BlinkingFinal check and trial operation English-51How to connect your extended power cables English-52Apply heat to the contraction tube to contract it After tube contraction work is completed, wrap it withMGGOODA3050IB&IMENDB68-04069A-00.indd 11/09/2013 Questions or COMMENTS? 0211