Samsung AR18HCFNBGM/MG, AR18HCFNBWK/MG, AR12HCFNBWKNMD Maintaining the air conditioner, English-26

Page 26

Maintaining the air conditioner

If the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it in best condition.

1. Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours and cut-off the power supply. There may be internal damage if moisture is left in components.

2.Before using the air conditioner again, dry the inner components of the air conditioner again by running in Fan mode for 3 to 4 hours. This helps remove odors which may have generated from dampness.

Periodical checks

Refer to the following chart to maintain the air conditioner properly.

Type

Description

Every 2

Every 3

Every 4

Once a year

weeks

months

months

 

 

 

 

 

 

 

 

 

 

Clean the Full HD filter (1)

 

 

 

 

 

 

 

 

 

 

Clean the condensate drain pan (2)

 

 

 

 

 

 

 

 

 

Indoor

Thoroughly clean the heat exchanger (2)

 

 

 

unit

Clean the cross fan (2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clean the condensate drain pipe (2)

 

 

 

 

 

 

 

 

 

 

Replace the remote controller batteries (1)

 

 

 

 

 

 

 

 

 

 

Clean the heat exchanger on the outside of the unit (2)

 

 

 

 

 

 

 

 

 

 

Clean the heat exchanger on the inside of the unit (2)

 

 

 

 

 

 

 

 

 

 

Clean the electric components with jets of air (2)

 

 

 

Outdoor

 

 

 

 

 

Verify that all the electric components are firmly

 

 

 

unit

tightened (2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clean the fan (2)

 

 

 

 

 

 

 

 

 

 

Verify that all the fan assembly is firmly tightened (2)

 

 

 

 

 

 

 

 

 

 

Clean the condensate drain pan (2)

 

 

 

 

 

 

 

 

 

: This check mark requires checking the indoor/outdoor unit periodically. Follow the description to maintain the air conditioner properly.

 

 

 

(1)

The described operations should be performed more frequently if

 

 

 

 

 

 

the area of installation is very dusty.

CAUTION

 

 

(2)

These operations must always be performed by qualified personnel.

 

 

 

 

 

For more detailed information, see the installation part in the

 

 

 

 

manual.

English-26

MG_GOOD_A3050_IB&IM_EN_DB68-04069A-00.indd 26

11/09/2013 21:10:48

Image 26
Contents Air Conditioner Features of your new air conditioner Contents Safety precautions English-4English-5 01epaPr n atioFor Using English-6English-7 Do not place objects or devices under the indoor unit English-8For Cleaning English-9English-10 Checking before useOperation ranges T05s In llan atio Technical SpecificationsEnglish-11 Display Checking the name of the partsMain parts English-12English-13 Checking the remote controllerRemote controller buttons Storing the remote controller Remote controller displayBattery changing time Inserting the batteriesBasic function English-16 Press the button to adjust the temperaturePress the button to set the desired fan speed Horizontal air flow Adjusting the air flow directionVertical air flow English-17English-18 Using the Fast functionUsing the Comfort function English-19 When the air conditioner is on and in cool/heat modeMode English-20 Setting the On/Off timerPress the On Timer/Off Timer button Turn off automatically From the moment you have set the timerIf the air conditioner is on If the air conditioner is off English-22 Using the Auto Clean functionWhen the air conditioner is turned on English-23 Cleaning the air conditionerCleaning the outdoor unit heat exchanger Sre04 OthEnglish-24 Cleaning the air filterRemoving the Air filter Remove the air filter from the main bodyTop of the Air filter into the main body.. ➀ Reassembling the Air filterEnglish-25 Maintaining the air conditioner English-26English-27 TroubleshootingAir conditioner Error is indicated Button or disconnect the power plug/switchCheck the Drains have been cleared Regular Maintenance Heard when refrigerant flow movement changes. It is normalGeneral information English-29Power supply line, fuse or circuit breaker Choosing the installation locationInstalling the unit Indoor unitEnglish-31 Where sulfide gas existsOutdoor Unit English-32 When installing more than 1 outdoor unitWhen the air outlet is towards the wall  Figure DescriptionEnglish-33 AccessoriesAccessories in the indoor unit case LlanTools required for installation General Tools Accessories in the outdoor unit caseOptional accessories Tools for test operationsEnglish-35 Fixing the installation plateAssembling the hanger screw Removing the Cover panel Before mounting the indoor unit This QR code for detail video of indoor unit installationRemoving the screws English-36Assembling the Cover panel After mounting the indoor unit English-37Connecting the cable Connecting the assembly cableCable specification English-38English-39 Extend the assembly cable if necessaryEach wire is labeled with the corresponding terminal number Cut off the remaining foam insulation English-40Smooth the cut edges TorqueEnglish-41 Evacuating the indoor unitCutting or extending the pipe Unscrew the caps at the end of each pipeDepth a English-42Put a flare nut slightly into the pipe and modify the flare Drain hose installation English-43Shield Change the direction only when it is necessaryEnglish-44 Downwards as seen in the pictureConnect a drain hose to the drain plug Evacuating the connected pipesEnglish-45 Drain hole Drain plugOuter Torque Adding RefrigerantEnglish-46 If you use a pipe longer than 5 mPerforming the gas leak tests English-47English-48 Outdoor unit installed on the wall by rackFixing the outdoor unit in place 12HC 507 12HP 543 18HC 602Smart Install mode English-49English-50 Off BlinkingFinal check and trial operation English-51Apply heat to the contraction tube to contract it How to connect your extended power cablesEnglish-52 After tube contraction work is completed, wrap it withMGGOODA3050IB&IMENDB68-04069A-00.indd 11/09/2013 Questions or COMMENTS? 0211