Choosing the installation location

(Unit : mm)

When the walls are blocking front and the rear side of the outdoor units

 

 

300 or more

600 or more

600 or more

1500 or more

When front and rear side of the outdoor unit is towards the wall

1500 or

600 or

3000 or

3000 or

200 or

more

more

more

more

more

When the upper part of the outdoor unit and the air outlet is opposite the wall

more

300 or more

t05s In

500 or

 

llan

 

 

atio

500 or more

300 or more

 

 

 

• If installation is done in inappropriate space, unit may generate sound and cause bad effect on the product.

• Installation must be done in level and in a place where vibration will not cause any effect.

Accessories

The following accessories are supplied with the air conditioner:

• The number of each accessory is indicated in parentheses.

Accessories in the indoor unit case

Installation Plate (1)

Installation Plate (1)

Remote controller (1)

Batteries for Remote

 

✴✴12✴✴

✴✴18/24✴✴

controller (2)

 

 

 

User’s & Installation

Remote Control Holder

M4 x 16 Tapped Screws

M4 x 10 Tapped Screws

Cap Screws (3)

Manual (1)

(1)

(2)

(2)

 

English-33

MG_GOOD_A3050_IB&IM_EN_DB68-04069A-00.indd 33

11/09/2013 21:10:57

Image 33
Contents Air Conditioner Features of your new air conditioner Contents English-4 Safety precautions01epaPr n atio English-5English-6 For UsingEnglish-7 English-8 Do not place objects or devices under the indoor unitEnglish-9 For CleaningChecking before use Operation rangesEnglish-10 Technical Specifications English-11T05s In llan atio Main parts Checking the name of the partsDisplay English-12Checking the remote controller Remote controller buttonsEnglish-13 Battery changing time Remote controller displayStoring the remote controller Inserting the batteriesBasic function Press the button to adjust the temperature Press the button to set the desired fan speedEnglish-16 Vertical air flow Adjusting the air flow directionHorizontal air flow English-17Using the Fast function Using the Comfort functionEnglish-18 When the air conditioner is on and in cool/heat mode ModeEnglish-19 Setting the On/Off timer Press the On Timer/Off Timer buttonEnglish-20 From the moment you have set the timer If the air conditioner is on If the air conditioner is offTurn off automatically Using the Auto Clean function When the air conditioner is turned onEnglish-22 Cleaning the outdoor unit heat exchanger Cleaning the air conditionerEnglish-23 Sre04 OthRemoving the Air filter Cleaning the air filterEnglish-24 Remove the air filter from the main bodyReassembling the Air filter English-25Top of the Air filter into the main body.. ➀ English-26 Maintaining the air conditionerTroubleshooting Air conditionerEnglish-27 Check the Drains have been cleared Regular Maintenance Button or disconnect the power plug/switchError is indicated Heard when refrigerant flow movement changes. It is normalEnglish-29 General informationInstalling the unit Choosing the installation locationPower supply line, fuse or circuit breaker Indoor unitWhere sulfide gas exists Outdoor UnitEnglish-31 When the air outlet is towards the wall When installing more than 1 outdoor unitEnglish-32  Figure DescriptionAccessories in the indoor unit case AccessoriesEnglish-33 LlanOptional accessories Accessories in the outdoor unit caseTools required for installation General Tools Tools for test operationsFixing the installation plate Assembling the hanger screwEnglish-35 Removing the screws This QR code for detail video of indoor unit installationRemoving the Cover panel Before mounting the indoor unit English-36English-37 Assembling the Cover panel After mounting the indoor unitCable specification Connecting the assembly cableConnecting the cable English-38Extend the assembly cable if necessary Each wire is labeled with the corresponding terminal numberEnglish-39 Smooth the cut edges English-40Cut off the remaining foam insulation TorqueCutting or extending the pipe Evacuating the indoor unitEnglish-41 Unscrew the caps at the end of each pipeEnglish-42 Put a flare nut slightly into the pipe and modify the flareDepth a English-43 Drain hose installationEnglish-44 Change the direction only when it is necessaryShield Downwards as seen in the pictureEnglish-45 Evacuating the connected pipesConnect a drain hose to the drain plug Drain hole Drain plugEnglish-46 Adding RefrigerantOuter Torque If you use a pipe longer than 5 mEnglish-47 Performing the gas leak testsFixing the outdoor unit in place Outdoor unit installed on the wall by rackEnglish-48 12HC 507 12HP 543 18HC 602English-49 Smart Install modeOff Blinking English-50English-51 Final check and trial operationEnglish-52 How to connect your extended power cablesApply heat to the contraction tube to contract it After tube contraction work is completed, wrap it withMGGOODA3050IB&IMENDB68-04069A-00.indd 11/09/2013 0211 Questions or COMMENTS?