Carefully follow the precautions listed below because they are essential to guarantee the safety of the equipment.

Always disconnect the air conditioner from the power supply before servicing it or accessing its internal components.

Verify that installation and testing operations are performed by qualified personnel.

Verify that the air conditioner is not installed in an easily accessible area.

General information

Carefully read the content of this manual before installing the air conditioner and store the manual in a safe place in order to be able to use it as reference after installation.

For maximum safety, installers should always carefully read the following warnings.

Store the operation and installation manual in a safe location and remember to hand it over to the new owner if the air conditioner is sold or transferred.

This manual explains how to install an indoor unit with a split system with two SAMSUNG units.

The use of other types of units with different control systems may damage the units and invalidate the warranty. The manufacturer shall not be responsible for damages arising from the use of non compliant units.

This product has been determined to be in compliance with the Low Voltage Directive (2006/95/EC), and the Electromagnetic Compatibility Directive (2004/108/EC) of the European Union.

The manufacturer shall not be responsible for damage originating from unauthorized changes or the improper connection of electric and requirements set forth in the“Operating limits”table, included in the manual, shall immediately invalidate the warranty.

The air conditioner should be used only for the applications for which it has been designed: the indoor unit is not suitable to be installed in areas used for laundry.

Do not use the units if damaged. If problems occur, switch the unit off and disconnect it from the power supply.

In order to help prevent electric shocks, fires or injuries, always stop the unit, disable the protection switch and contact SAMSUNG’s technical support if the unit produces smoke, if the power cable is hot or damaged or if the unit is very noisy.

Always remember to inspect the unit, electric connections, refrigerant tubes and protections regularly. These operations should be performed by qualified personnel only.

The unit contains moving parts, which should always be kept out of the reach of children.

Do not attempt to repair, move, alter or reinstall the unit. If performed by unauthorized personnel, these operations may cause electric shocks or fires.

Do not place containers with liquids or other objects on the unit.

All the materials used for the manufacture and packaging of the air conditioner are recyclable.

The packing material and exhaust batteries of the remote controller(optional) must be disposed of in accordance with current laws.

The air conditioner contains a refrigerant that has to be disposed of as special waste. At the end of its life cycle, the air conditioner must be disposed of in authorized centers or returned to the retailer so that it can be disposed of correctly and safely.

t05s In llan atio

English-29

MG_GOOD_A3050_IB&IM_EN_DB68-04069A-00.indd 29

11/09/2013 21:10:49

Image 29
Contents Air Conditioner Features of your new air conditioner Contents English-4 Safety precautions01epaPr n atio English-5English-6 For UsingEnglish-7 English-8 Do not place objects or devices under the indoor unitEnglish-9 For CleaningEnglish-10 Checking before useOperation ranges T05s In llan atio Technical SpecificationsEnglish-11 Main parts Checking the name of the partsDisplay English-12English-13 Checking the remote controllerRemote controller buttons Battery changing time Remote controller displayStoring the remote controller Inserting the batteriesBasic function English-16 Press the button to adjust the temperaturePress the button to set the desired fan speed Vertical air flow Adjusting the air flow directionHorizontal air flow English-17English-18 Using the Fast functionUsing the Comfort function English-19 When the air conditioner is on and in cool/heat modeMode English-20 Setting the On/Off timerPress the On Timer/Off Timer button Turn off automatically From the moment you have set the timerIf the air conditioner is on If the air conditioner is off English-22 Using the Auto Clean functionWhen the air conditioner is turned on Cleaning the outdoor unit heat exchanger Cleaning the air conditionerEnglish-23 Sre04 OthRemoving the Air filter Cleaning the air filterEnglish-24 Remove the air filter from the main bodyTop of the Air filter into the main body.. ➀ Reassembling the Air filterEnglish-25 English-26 Maintaining the air conditionerEnglish-27 TroubleshootingAir conditioner Check the Drains have been cleared Regular Maintenance Button or disconnect the power plug/switchError is indicated Heard when refrigerant flow movement changes. It is normalEnglish-29 General informationInstalling the unit Choosing the installation locationPower supply line, fuse or circuit breaker Indoor unitEnglish-31 Where sulfide gas existsOutdoor Unit When the air outlet is towards the wall When installing more than 1 outdoor unitEnglish-32  Figure DescriptionAccessories in the indoor unit case AccessoriesEnglish-33 LlanOptional accessories Accessories in the outdoor unit caseTools required for installation General Tools Tools for test operationsEnglish-35 Fixing the installation plateAssembling the hanger screw Removing the screws This QR code for detail video of indoor unit installationRemoving the Cover panel Before mounting the indoor unit English-36English-37 Assembling the Cover panel After mounting the indoor unitCable specification Connecting the assembly cableConnecting the cable English-38English-39 Extend the assembly cable if necessaryEach wire is labeled with the corresponding terminal number Smooth the cut edges English-40Cut off the remaining foam insulation TorqueCutting or extending the pipe Evacuating the indoor unitEnglish-41 Unscrew the caps at the end of each pipeDepth a English-42Put a flare nut slightly into the pipe and modify the flare English-43 Drain hose installationEnglish-44 Change the direction only when it is necessaryShield Downwards as seen in the pictureEnglish-45 Evacuating the connected pipesConnect a drain hose to the drain plug Drain hole Drain plugEnglish-46 Adding RefrigerantOuter Torque If you use a pipe longer than 5 mEnglish-47 Performing the gas leak testsFixing the outdoor unit in place Outdoor unit installed on the wall by rackEnglish-48 12HC 507 12HP 543 18HC 602English-49 Smart Install modeOff Blinking English-50English-51 Final check and trial operationEnglish-52 How to connect your extended power cablesApply heat to the contraction tube to contract it After tube contraction work is completed, wrap it withMGGOODA3050IB&IMENDB68-04069A-00.indd 11/09/2013 0211 Questions or COMMENTS?