Samsung AR24HCFNBWKNMG Fixing the installation plate, Assembling the hanger screw, English-35

Page 35

Fixing the installation plate

You can select the direction of the drain hose depending on where you want to install the indoor unit. Therefore before fixing the installation plate to a wall or a window frame, you must determine the position of the 65 mm hole through which the cable, pipe and hose pass to connect the indoor unit to the outdoor unit.

When facing the wall, the pipe and cable can be connected from the:

• Right (A)

Direction of pipe

 

 

 

• Left (B)

 

 

• Underside_right (C)

A

B

• Rear_right or left (D)

D

D

 

C

 

1.Determine the position of the pipe and drain hose hole as seen in the picture and drill the hole with an inner diameter of 65 mm so that it slants slightly downwards.

Pipe hole (Ø65 mm)

 

 

 

Pipe hole (Ø65 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

t05s In llan atio

A

B

D

A

C

B

D

C

(Unit : mm)

 

Model

A

B

C

D

 

12

0

171

30

0

 

 

 

 

 

 

 

18/24

5

161

52

5

2. Fix the indoor unit.

 

 

 

 

If you fix the indoor unit

on a

wall

 

 

Make sure to drill only one hole after choosing the direction of the pipe.

(1) Fix the installation plate to the wall giving attention to the weight of the indoor unit.

Plastic

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• If you mount the plate to a concrete wall using plastic anchors, make sure that gaps

Anchor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

< 20 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

between the wall and the plate, created by projected anchor, is less than 20 mm.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wall

If you fix the indoor unit on a window frame

(1)Determine the positions of the wooden uprights to be attached to the window frame.

(2)Attach the wooden uprights to the window frame giving attention to the weight of the indoor unit.

(3)Attach the installation plate to the wooden upright using tapping screws.

If you fix the indoor unit on a gypsum board

(1)Use stud finder to find out locations of the studs.

(2)Fix the plate hanger on two studs.

• Search for other spots if there are less than two studs, or the distance between the studs are different from the plate hanger.

Fix the installation plate without inclining to one side.

Make sure that a wall can withstand the weight of the product. If you install the product in a place where it is not

strong enough to withstand the product weight, the unit could fall and cause injury.

Assembling the hanger screw

Use 2 screws to fix the indoor unit as shown in the picture.

Screw(M4x10)

English-35

MG_GOOD_A3050_IB&IM_EN_DB68-04069A-00.indd 35

11/09/2013 21:11:07

Image 35
Contents Air Conditioner Features of your new air conditioner Contents English-4 Safety precautions01epaPr n atio English-5English-6 For UsingEnglish-7 English-8 Do not place objects or devices under the indoor unitEnglish-9 For CleaningEnglish-10 Checking before useOperation ranges T05s In llan atio Technical SpecificationsEnglish-11 English-12 Checking the name of the partsMain parts DisplayEnglish-13 Checking the remote controllerRemote controller buttons Inserting the batteries Remote controller displayBattery changing time Storing the remote controllerBasic function English-16 Press the button to adjust the temperaturePress the button to set the desired fan speed English-17 Adjusting the air flow directionVertical air flow Horizontal air flowEnglish-18 Using the Fast functionUsing the Comfort function English-19 When the air conditioner is on and in cool/heat modeMode English-20 Setting the On/Off timerPress the On Timer/Off Timer button Turn off automatically From the moment you have set the timerIf the air conditioner is on If the air conditioner is off English-22 Using the Auto Clean functionWhen the air conditioner is turned on Sre04 Oth Cleaning the air conditionerCleaning the outdoor unit heat exchanger English-23Remove the air filter from the main body Cleaning the air filterRemoving the Air filter English-24Top of the Air filter into the main body.. ➀ Reassembling the Air filterEnglish-25 English-26 Maintaining the air conditionerEnglish-27 TroubleshootingAir conditioner Heard when refrigerant flow movement changes. It is normal Button or disconnect the power plug/switchCheck the Drains have been cleared Regular Maintenance Error is indicatedEnglish-29 General informationIndoor unit Choosing the installation locationInstalling the unit Power supply line, fuse or circuit breakerEnglish-31 Where sulfide gas existsOutdoor Unit  Figure Description When installing more than 1 outdoor unitWhen the air outlet is towards the wall English-32Llan AccessoriesAccessories in the indoor unit case English-33Tools for test operations Accessories in the outdoor unit caseOptional accessories Tools required for installation General ToolsEnglish-35 Fixing the installation plateAssembling the hanger screw English-36 This QR code for detail video of indoor unit installationRemoving the screws Removing the Cover panel Before mounting the indoor unitEnglish-37 Assembling the Cover panel After mounting the indoor unitEnglish-38 Connecting the assembly cableCable specification Connecting the cableEnglish-39 Extend the assembly cable if necessaryEach wire is labeled with the corresponding terminal number Torque English-40Smooth the cut edges Cut off the remaining foam insulationUnscrew the caps at the end of each pipe Evacuating the indoor unitCutting or extending the pipe English-41Depth a English-42Put a flare nut slightly into the pipe and modify the flare English-43 Drain hose installationDownwards as seen in the picture Change the direction only when it is necessaryEnglish-44 ShieldDrain hole Drain plug Evacuating the connected pipesEnglish-45 Connect a drain hose to the drain plugIf you use a pipe longer than 5 m Adding RefrigerantEnglish-46 Outer TorqueEnglish-47 Performing the gas leak tests12HC 507 12HP 543 18HC 602 Outdoor unit installed on the wall by rackFixing the outdoor unit in place English-48English-49 Smart Install modeOff Blinking English-50English-51 Final check and trial operationAfter tube contraction work is completed, wrap it with How to connect your extended power cablesEnglish-52 Apply heat to the contraction tube to contract itMGGOODA3050IB&IMENDB68-04069A-00.indd 11/09/2013 0211 Questions or COMMENTS?