Fixing the installation plate
You can select the direction of the drain hose depending on where you want to install the indoor unit. Therefore before fixing the installation plate to a wall or a window frame, you must determine the position of the 65 mm hole through which the cable, pipe and hose pass to connect the indoor unit to the outdoor unit.
When facing the wall, the pipe and cable can be connected from the:
• Right (A) | Direction of pipe |
|
|
| |
• Left (B) |
|
|
• Underside_right (C) | A | B |
• Rear_right or left (D) | D | D |
| C |
|
1.Determine the position of the pipe and drain hose hole as seen in the picture and drill the hole with an inner diameter of 65 mm so that it slants slightly downwards.
Pipe hole (Ø65 mm) |
|
|
| Pipe hole (Ø65 mm) |
|
| |||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
t05s In llan atio
A
B
D | A |
C
B
D
C
(Unit : mm)
| Model | A | B | C | D |
| 12 | 0 | 171 | 30 | 0 |
|
|
|
|
|
|
| 18/24 | 5 | 161 | 52 | 5 |
2. Fix the indoor unit. |
|
|
|
| |
If you fix the indoor unit | on a | wall |
|
|
•Make sure to drill only one hole after choosing the direction of the pipe.
(1) Fix the installation plate to the wall giving attention to the weight of the indoor unit. | Plastic |
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
| • If you mount the plate to a concrete wall using plastic anchors, make sure that gaps | Anchor |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| < 20 mm |
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
| between the wall and the plate, created by projected anchor, is less than 20 mm. |
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Wall
If you fix the indoor unit on a window frame
(1)Determine the positions of the wooden uprights to be attached to the window frame.
(2)Attach the wooden uprights to the window frame giving attention to the weight of the indoor unit.
(3)Attach the installation plate to the wooden upright using tapping screws.
If you fix the indoor unit on a gypsum board
(1)Use stud finder to find out locations of the studs.
(2)Fix the plate hanger on two studs.
• Search for other spots if there are less than two studs, or the distance between the studs are different from the plate hanger.
•Fix the installation plate without inclining to one side.
•Make sure that a wall can withstand the weight of the product. If you install the product in a place where it is not
strong enough to withstand the product weight, the unit could fall and cause injury.
Assembling the hanger screw
Use 2 screws to fix the indoor unit as shown in the picture.
Screw(M4x10)
English-35
11/09/2013 21:11:07