Samsung AR24HCFNBWKXMG, AR18HCFNBWK/MG If the air conditioner is on If the air conditioner is off

Page 21

Setting the On/Off timer

Combining On Timer and Off Timer

If the air conditioner is on

If the air conditioner is off

 

 

Preset time on On timer is longer than Off timer

Preset time on On timer is shorter than Off timer

Ex) On timer : 3 hours, Off timer : 1 hour

Ex) On timer : 3 hours, Off timer : 5 hours

- The air conditioner will operate the Off timer after

- The air conditioner will operate On timer after 3 hours

1 hour from the moment you have set the timer.

from the moment you have set the timer.

Your air conditioner will turn on after 2 hours.

Your air conditioner will remain on for 2 hours and then

 

turn off automatically.

 

 

• On timer and Off timer setting time should be different from each other.

• Press the Cancel button on the remote controller while timer combination is on. Both of the On and Off timer will be canceled and the indicator will disappear.

c f03undAdvance n iot

Using the Single User function

This function will reduce the energy usage while the air conditioner is operating in Cool/Heat mode.

Press the Single User button on the remote controller while the air conditioner is operating in Cool/Heat mode.

" " appears on the remote controller display for few seconds and

disappears.

Single User indicator and air swing indicator appear automatically on the remote controller display.

The air flow blades move up and down.

If the current set temperature is lower than 24°C in Cool mode, it will be automatically raised to 24 °C.

Cancel Press the Single User button once again.

• Single User function is only available in Cool/Heat mode.

• When Single User function is activated in Cool mode, temperature range will be limited to 24 °C~30 °C. However, temperature range during Heat mode will remain same at 16 °C~30 °C.

If the desired temperature is lower than 24 °C in Cool mode, turn off the Single

User function by pressing the Single User button again.

Temperature/Fan speed can also be adjusted (see page 16 for instructions).

Air flow can be adjusted. (see page 17 for instruction).

If you press the Mode button while the Single User function is on, it will cancel the function.

English-21

MG_GOOD_A3050_IB&IM_EN_DB68-04069A-00.indd 21

11/09/2013 21:10:45

Image 21
Contents Air Conditioner Features of your new air conditioner Contents English-4 Safety precautions01epaPr n atio English-5English-6 For UsingEnglish-7 English-8 Do not place objects or devices under the indoor unitEnglish-9 For CleaningChecking before use Operation rangesEnglish-10 Technical Specifications English-11T05s In llan atio Main parts Checking the name of the partsDisplay English-12Checking the remote controller Remote controller buttonsEnglish-13 Battery changing time Remote controller displayStoring the remote controller Inserting the batteriesBasic function Press the button to adjust the temperature Press the button to set the desired fan speedEnglish-16 Vertical air flow Adjusting the air flow directionHorizontal air flow English-17Using the Fast function Using the Comfort functionEnglish-18 When the air conditioner is on and in cool/heat mode ModeEnglish-19 Setting the On/Off timer Press the On Timer/Off Timer buttonEnglish-20 From the moment you have set the timer If the air conditioner is on If the air conditioner is offTurn off automatically Using the Auto Clean function When the air conditioner is turned onEnglish-22 Cleaning the outdoor unit heat exchanger Cleaning the air conditionerEnglish-23 Sre04 OthRemoving the Air filter Cleaning the air filterEnglish-24 Remove the air filter from the main bodyReassembling the Air filter English-25Top of the Air filter into the main body.. ➀ English-26 Maintaining the air conditionerTroubleshooting Air conditionerEnglish-27 Check the Drains have been cleared Regular Maintenance Button or disconnect the power plug/switchError is indicated Heard when refrigerant flow movement changes. It is normalEnglish-29 General informationInstalling the unit Choosing the installation locationPower supply line, fuse or circuit breaker Indoor unitWhere sulfide gas exists Outdoor UnitEnglish-31 When the air outlet is towards the wall When installing more than 1 outdoor unitEnglish-32  Figure DescriptionAccessories in the indoor unit case AccessoriesEnglish-33 LlanOptional accessories Accessories in the outdoor unit caseTools required for installation General Tools Tools for test operationsFixing the installation plate Assembling the hanger screwEnglish-35 Removing the screws This QR code for detail video of indoor unit installationRemoving the Cover panel Before mounting the indoor unit English-36English-37 Assembling the Cover panel After mounting the indoor unitCable specification Connecting the assembly cableConnecting the cable English-38Extend the assembly cable if necessary Each wire is labeled with the corresponding terminal numberEnglish-39 Smooth the cut edges English-40Cut off the remaining foam insulation TorqueCutting or extending the pipe Evacuating the indoor unitEnglish-41 Unscrew the caps at the end of each pipeEnglish-42 Put a flare nut slightly into the pipe and modify the flareDepth a English-43 Drain hose installationEnglish-44 Change the direction only when it is necessaryShield Downwards as seen in the pictureEnglish-45 Evacuating the connected pipesConnect a drain hose to the drain plug Drain hole Drain plugEnglish-46 Adding RefrigerantOuter Torque If you use a pipe longer than 5 mEnglish-47 Performing the gas leak testsFixing the outdoor unit in place Outdoor unit installed on the wall by rackEnglish-48 12HC 507 12HP 543 18HC 602English-49 Smart Install modeOff Blinking English-50English-51 Final check and trial operationEnglish-52 How to connect your extended power cablesApply heat to the contraction tube to contract it After tube contraction work is completed, wrap it withMGGOODA3050IB&IMENDB68-04069A-00.indd 11/09/2013 0211 Questions or COMMENTS?