Samsung AR24KQJSBWKNMG manual Drilling a hole through the wall, Tools

Page 37

Installation

NOTE

A flare nut is attached to the end of each pipe of an evaporator or a service port. Use flare nuts when connecting the pipes.

Wire assembly cables are optional. If they are not supplied, use standard cables.

The drain plug and the rubber legs are included only when the air conditioner is supplied without assembly pipes.

If these accessories are supplied, they are in the accessory package or outdoor unit package.

Tools

General tools

Vacuum pump

(Backward flowing prevention)

Manifold gauge

Stud finder

Torque wrench

Pipe cutter

Reamer

Pipe bender

Spirit level

Screwdriver

Spanner

Drill

L-wrench

Measuring tape

Tools for test operation

Thermometer

Resistance meter

Electroscope

36English

Step 1.4 Drilling a hole through the wall

Before fixing the installation plate to a wall and then fixing the indoor unit to the installation plate, a window frame, or a gypsum board, you must determine the position of a hole (with 65 mm inner diameter) through which the pipe bundle (consisting of power and communication cables, refrigerant pipes, and drain hose) will pass and then drill that hole.

1Determine the position of a 65 mm hole in consideration of the possible directions of the pipe bundle and the minimum distances between the hole and the installation plate.

Left

Right

 

Rear right or left

Bottom right

<Possible directions of the pipe bundle>

CAUTION

If changing the pipe direction from left to right, do not drastically bent it but slowly turn it in the opposite direction as shown. Otherwise, the pipe may be damaged in the process.

Pipe bundle hole

<Minimum distances between the hole and the

 

installation plate>

 

(Unit : mm)

 

 

 

 

 

 

 

 

 

 

 

 

Model

 

A

B

C

 

D

 

 

 

 

 

 

 

✴✴18/24✴✴

 

33

110

110

 

33

 

 

 

 

 

 

 

 

 

Pipe bundle hole: Ø 65 mm

MG_GOOD_R-410A_A3050_IB&IM_EN_ DB68-06070A-00.indd 36

12-May-16 11:29:44 AM

Image 37
Contents Samsung Air conditionergioner Contents Safety Information on Installation Preparation InstallationFor Installation Safety InformationSafety Information For Power Supply For Using Safety Information Safety Information For Cleaning MGGOODR-410AA3050IB&IMEN DB68-06070A-00.indd Display Indoor Unit OverviewInserting batteries Remote Control OverviewControlling temperature Remote Control OperationOperation modes Controlling air flow direction Controlling fan speedCooling Operation Cool modeStep cooling function Dehumidifying Operation Dry modeHeating Operation Heat modeAuto mode Quick Smart FeaturesFan mode Fast function Beep sound function Comfort functionSingle user function Energy-Saving OperationTimed on/Timed off function Good’sleep function Running Auto clean Cleaning at a GlanceCleaning the filter Troubleshooting Cleaning and Maintenance Thailand Technical SpecificationsModel AR24KRJSRWK/MG AR24KQJSBWK/MG General information Safety Information on InstallationPower supply line, fuse, or circuit breaker Overview of installation location requirements Choosing the installation location Preparation Minimum clearances for the outdoor unitIndoor unit Packing and UnpackingOutdoor unit Accessories Checking and preparing accessories and toolsTools Drilling a hole through the wallTaping the pipes, cables, and drain hose Disassembling the installation plate Indoor Unit InstallationDisassembling the cover panel Assembly cable Connecting the cablesPrepare a compressor and the following tools Optional Extending the power cableOptional Extending the drain hose Installing and connecting the drain hoseOptional Changing the direction of the drain hose Shortening or extending the refrigerant pipes assembly pipe When fixing the indoor unit on a wall 10 Fixing the installation plateWhen fixing the indoor unit on a window frame When fixing the indoor unit on a gypsum board 11 Fixing the indoor unit to the installation plate12 Assembling the cover panel Connecting the cables and the refrigerant pipes Outdoor Unit InstallationFixing the outdoor unit in place Optional Fixing the outdoor unit to a wall with a rackEvacuating the air Adding refrigerant Running the Smart Install mode Installation InspectionPerforming the gas leak tests LED Pumping down refrigerant Performing final check and trial operationPumping down for removing the product
Related manuals