Samsung AR24KQJSBWKNMG manual Fixing the indoor unit to the installation plate

Page 46

When fixing the indoor unit on a gypsum board

1Use stud finder to find out locations of the studs.

2Fix the plate hanger on two studs.

CAUTION

If you fix the indoor unit on a gypsum board, use only specified anchor bolts on reference positions. Otherwise, the gypsum surrounding the joints may crumble over time and cause the screws to be loosened and stripped. This may lead to physical injury or equipment damage.

Search for other spots if there are less than two studs, or the distance between the studs are different from the plate hanger.

Fix the installation plate without inclining to one side.

Step 2.11 Fixing the indoor unit to the installation plate

CAUTION

Make sure that the pipe bundle does not move when you install the indoor unit onto the installation plate.

Step 2.12 Assembling the cover panel

1Lock the side hooks (D), then centre hooks (B). Then lock the bottom hooks (C) to engage the cover panel in place.

2Fasten the screw (A-), then assemble the cap screws (A-).

A B

A B

CD

C

2

D

1

BB

C C

Installation

A

A

1

2

English 45

MG_GOOD_R-410A_A3050_IB&IM_EN_ DB68-06070A-00.indd 45

12-May-16 11:29:58 AM

Image 46
Contents Samsung Air conditionergioner Contents Installation Safety Information on Installation PreparationSafety Information For InstallationSafety Information For Power Supply For Using Safety Information Safety Information For Cleaning MGGOODR-410AA3050IB&IMEN DB68-06070A-00.indd Indoor Unit Overview DisplayRemote Control Overview Inserting batteriesControlling temperature Remote Control OperationOperation modes Controlling fan speed Controlling air flow directionCooling Operation Cool modeStep cooling function Dry mode Dehumidifying OperationHeat mode Heating OperationAuto mode Quick Smart FeaturesFan mode Fast function Comfort function Beep sound functionEnergy-Saving Operation Single user functionTimed on/Timed off function Good’sleep function Cleaning at a Glance Running Auto cleanCleaning the filter Troubleshooting Cleaning and Maintenance Technical Specifications ThailandModel AR24KRJSRWK/MG AR24KQJSBWK/MG Safety Information on Installation General informationPower supply line, fuse, or circuit breaker Preparation Choosing the installation locationOverview of installation location requirements Minimum clearances for the outdoor unitIndoor unit Packing and UnpackingOutdoor unit Checking and preparing accessories and tools AccessoriesDrilling a hole through the wall ToolsTaping the pipes, cables, and drain hose Disassembling the installation plate Indoor Unit InstallationDisassembling the cover panel Connecting the cables Assembly cableOptional Extending the power cable Prepare a compressor and the following toolsInstalling and connecting the drain hose Optional Extending the drain hoseOptional Changing the direction of the drain hose Shortening or extending the refrigerant pipes assembly pipe When fixing the indoor unit on a wall 10 Fixing the installation plateWhen fixing the indoor unit on a window frame When fixing the indoor unit on a gypsum board 11 Fixing the indoor unit to the installation plate12 Assembling the cover panel Fixing the outdoor unit in place Outdoor Unit InstallationConnecting the cables and the refrigerant pipes Optional Fixing the outdoor unit to a wall with a rackEvacuating the air Adding refrigerant Running the Smart Install mode Installation InspectionPerforming the gas leak tests LED Pumping down refrigerant Performing final check and trial operationPumping down for removing the product
Related manuals
Manual 53 pages 47.38 Kb