Samsung AR24KQJSBWKNMG manual Installation Inspection, Performing the gas leak tests

Page 50

Installation Inspection

Step 4.1 Performing the gas leak tests

1Before inspecting the leakage, use a torque wrench to close the cap for the stop valve. (Comply with a tightening torque for each size of the diameter, and tighten the cap firmly to prevent any leakage.)

Tightening torque for body cap (Refer to the table)

Charging core

Spindle

R-22: Thread of the screw - 7/16-2OUNF

R-410A: Thread of the screw -1/2-2OUNF

Tightening torque for charging port cap (Refer to the table)

Outer diameter

Tightening torque

 

 

Body cap

 

(mm)

Charging port cap (N•m)

 

(N•m)

 

 

 

 

 

ø 6.35

20 to 25

 

 

 

 

ø 9.52

20 to 25

 

 

 

 

ø 12.70

25 to 30

10 to 12

 

 

 

ø 15.88

30 to 35

 

 

 

 

Over ø 19.05

35 to 40

 

 

 

 

( 1 N•m = 10 kgf•cm )

2Insert inert gas into the pipes connected to indoor and outdoor units.

3Test leakage on the connection parts of the indoor and outdoor units with soap lather or liquid.

Test parts for the indoor unit

Test parts for the indoor unit

Step 4.2 Running the Smart Install mode

1Make sure that the air conditioner is in the standby status.

2Hold down the (Power), (Mode), and (SET) buttons on the remote control simultaneously for 4 seconds.

3Wait until Smart Install mode succeeds or fails. It takes approximately 7 to 13 minutes.

• While Smart Install mode is proceeding:

Type

Display

LED Display

 

 

 

 

 

 

 

 

 

 

 

 

LED1

 

 

 

 

 

 

 

 

LED2

 

 

 

 

 

 

 

 

LED3

 

Indoor

 

 

 

 

unit

The progress is

The LEDs on the

indicator

displayed as a

indoor unit display

 

 

number between

blink in sequence,

 

0 and 99 on

then all of them blink

 

the indoor unit

simultaneously. These

 

display.

operations repeat.

 

 

 

 

 

When Smart Install mode succeeds: Smart Install mode ends with ringing sound, and the air conditioner is in standby status.

When Smart Install mode fails: An error message is displayed on the indoor unit display, and Smart Install mode ends.

NOTE

Smart Install mode can be operated only with the supplied remote control.

During the Smart install mode procedure, remote control cannot be operated.

Installation

English 49

MG_GOOD_R-410A_A3050_IB&IM_EN_ DB68-06070A-00.indd 49

12-May-16 11:30:03 AM

Image 50
Contents Samsung Air conditionergioner Contents Installation Safety Information on Installation PreparationSafety Information For InstallationSafety Information For Power Supply For Using Safety Information Safety Information For Cleaning MGGOODR-410AA3050IB&IMEN DB68-06070A-00.indd Indoor Unit Overview DisplayRemote Control Overview Inserting batteriesOperation modes Remote Control OperationControlling temperature Controlling fan speed Controlling air flow directionStep cooling function Cool modeCooling Operation Dry mode Dehumidifying OperationHeat mode Heating OperationFan mode Quick Smart FeaturesAuto mode Fast function Comfort function Beep sound functionEnergy-Saving Operation Single user functionTimed on/Timed off function Good’sleep function Cleaning at a Glance Running Auto cleanCleaning the filter Troubleshooting Cleaning and Maintenance Technical Specifications ThailandModel AR24KRJSRWK/MG AR24KQJSBWK/MG Safety Information on Installation General informationPower supply line, fuse, or circuit breaker Preparation Choosing the installation locationOverview of installation location requirements Minimum clearances for the outdoor unitOutdoor unit Packing and UnpackingIndoor unit Checking and preparing accessories and tools AccessoriesDrilling a hole through the wall ToolsTaping the pipes, cables, and drain hose Disassembling the cover panel Indoor Unit InstallationDisassembling the installation plate Connecting the cables Assembly cableOptional Extending the power cable Prepare a compressor and the following toolsInstalling and connecting the drain hose Optional Extending the drain hoseOptional Changing the direction of the drain hose Shortening or extending the refrigerant pipes assembly pipe When fixing the indoor unit on a window frame 10 Fixing the installation plateWhen fixing the indoor unit on a wall 12 Assembling the cover panel 11 Fixing the indoor unit to the installation plateWhen fixing the indoor unit on a gypsum board Fixing the outdoor unit in place Outdoor Unit InstallationConnecting the cables and the refrigerant pipes Optional Fixing the outdoor unit to a wall with a rackEvacuating the air Adding refrigerant Performing the gas leak tests Installation InspectionRunning the Smart Install mode LED Pumping down for removing the product Performing final check and trial operationPumping down refrigerant