Samsung AR24KQJSBWKNMG manual Installing and connecting the drain hose

Page 42

WARNING

In case of extending the electric wire, please DO NOT use a round-shaped pressing socket.

––Incomplete wire

connections can cause electric shock or a fire.

Step 2.5 Installing and connecting the drain hose

1Install the drain hose.

CAUTION

Make sure that the indoor unit is in upright position when you pour water to check for leakage. Make sure that the water does not overflow onto the electrical part.

If the diameter of the connection hose is smaller than the product's drain hose, water leakage may occur.

Inadequate installation may cause water leakage.

If the drain hose is routed inside the room, insulate the hose so that dripping condensation does not damage the furniture or floors.

Do not box in or cover the drain hose connection. Drain hose connection must be easily accessible and serviceable.

Step 2.6 Optional: Extending the drain hose

Drain hose

Assembly pipe

Connection hose

 

 

 

 

Drain hose (A)

Extension drain hose (B)

Wall

 

 

 

 

Indoor unit

 

 

 

 

Drain hose

 

Water

 

 

 

 

 

 

Slant downwards

Slant upwards

Dipped in water

 

 

 

 

 

(A)

(B)

 

 

Drain hose

Extension drain hose

 

5 cm

 

 

 

 

less

Ditch

 

 

 

 

 

 

Bent

Too small

Too small

 

 

 

clearance

clearance

 

20 mm or more

Foam insulation

2Pour water into the drain pan. Check whether the

hose is well drained.

Vinyl tape

English 41

Installation

MG_GOOD_R-410A_A3050_IB&IM_EN_ DB68-06070A-00.indd 41

12-May-16 11:29:53 AM

Image 42
Contents Samsung Air conditionergioner Contents Installation Safety Information on Installation PreparationSafety Information For InstallationSafety Information For Power Supply For Using Safety Information Safety Information For Cleaning MGGOODR-410AA3050IB&IMEN DB68-06070A-00.indd Indoor Unit Overview DisplayRemote Control Overview Inserting batteriesRemote Control Operation Controlling temperatureOperation modes Controlling fan speed Controlling air flow directionCool mode Cooling OperationStep cooling function Dry mode Dehumidifying OperationHeat mode Heating OperationQuick Smart Features Auto modeFan mode Fast function Comfort function Beep sound functionEnergy-Saving Operation Single user functionTimed on/Timed off function Good’sleep function Cleaning at a Glance Running Auto cleanCleaning the filter Troubleshooting Cleaning and Maintenance Technical Specifications ThailandModel AR24KRJSRWK/MG AR24KQJSBWK/MG Safety Information on Installation General informationPower supply line, fuse, or circuit breaker Preparation Choosing the installation locationOverview of installation location requirements Minimum clearances for the outdoor unitPacking and Unpacking Indoor unitOutdoor unit Checking and preparing accessories and tools AccessoriesDrilling a hole through the wall ToolsTaping the pipes, cables, and drain hose Indoor Unit Installation Disassembling the installation plate Disassembling the cover panel Connecting the cables Assembly cableOptional Extending the power cable Prepare a compressor and the following toolsInstalling and connecting the drain hose Optional Extending the drain hoseOptional Changing the direction of the drain hose Shortening or extending the refrigerant pipes assembly pipe 10 Fixing the installation plate When fixing the indoor unit on a wallWhen fixing the indoor unit on a window frame 11 Fixing the indoor unit to the installation plate When fixing the indoor unit on a gypsum board12 Assembling the cover panel Fixing the outdoor unit in place Outdoor Unit InstallationConnecting the cables and the refrigerant pipes Optional Fixing the outdoor unit to a wall with a rackEvacuating the air Adding refrigerant Installation Inspection Running the Smart Install modePerforming the gas leak tests LED Performing final check and trial operation Pumping down refrigerantPumping down for removing the product
Related manuals
Manual 53 pages 47.38 Kb