Desa TPNPA-A Continued, installation for vertical Termination, Venting with Two 90 Elbows

Models: TPNA-A(-HA) TPNPEA-A TPNEA-A TSTPA-A TSTA-A(-HA) TSTPEA-A TPNPA-A TSTEA-A (V)DVF36

1 36
Download 36 pages 57.34 Kb
Page 15
Image 15
Venting with Two 90° Elbows

Venting Installation

Instructions

Continued

Horizontal Termination Configurations Figures 22 and 23 show different configurations for venting with horizontal termination. Each figure includes a chart with vertical minimum/maximum and horizontal maximum dimensions which must be met. All connections must be sealed with high temperature silicone sealant as specified in the second warning statement on page 11. All horizontal terminations require 1/4" rise per 12" of horizontal run. You must add 1/4" of vertical height (V) in the following tables for each foot of horizontal run (H).

45° Starter

Elbow

45° Starter

Elbow

Venting with Two 90° Elbows

Vertical (V)

Horizontal (H1) +

 

Horizontal (H2)

5' min.

4' max.

6' min.

8' max.

7' min.

10' max.

8' min.

15' max.

20' max.

20' max.

Figure 23 - Horizontal Termination Configuration for Rigid Venting Using Two 90° Elbows with Termination at 90° with Fireplace

Horizontal Venting

Vertical (V)

Horizontal (H)

49.5" min.

17" max.

(45° elbow, 1' vertical pipe, 90° elbow)

60" min.

77" max.

72" min.

101" max.

84" min.

125" max.

132" min.

149" max.

Figure 22 - Horizontal Termination Configuration for Rigid Venting Using One 90° Elbow

installation for vertical Termination

NOTICE: Use rigid pipe only. Flex venting is not to be used with a vertical termination.

1.Determine the route your vertical venting will take. If ceiling joists, roof rafters, or other framing will obstruct the venting system, consider an offset (see Figure 24) to avoid cutting load bearing members.

Roof

Flashing

 

Plumber’s

 

(2) 45°

Tape

 

Elbows

Connected

 

 

to Wall

 

 

Strap

 

 

Wall

(2) 45°

 

Strap

Elbows

Firestop Firestop

Figure 24 - Vertical Cent Pipe Offsets

56131-F

www.desatech.com

15

Page 15
Image 15
Desa TPNPA-A, (V)DVF36 Continued, installation for vertical Termination, Venting with Two 90 Elbows, Horizontal Venting