Desa TSTA-A(-HA) Continued, Unit, Minimum Clearances See-ThruShown, Rough Opening for Installing

Models: TPNA-A(-HA) TPNPEA-A TPNEA-A TSTPA-A TSTA-A(-HA) TSTPEA-A TPNPA-A TSTEA-A (V)DVF36

1 36
Download 36 pages 57.34 Kb
Page 7
Image 7
Figure 5 - Minimum Clearances

Pre-Installation

Preparation

 

Continued

 

 

Combustible Material

Drywall

Left Side

TOP VIEW

 

0"

Surround

 

 

 

(0" Min.)

 

 

 

 

 

 

2 x 4

 

 

 

Stud

Right Side

 

 

 

Surround

2"

 

 

(0" Min.)

 

36"

 

Wall In Front Of Glass

Perpendicular

 

36" Min.

 

 

Wall 2" Min.

 

 

 

 

 

From Opening

 

 

 

Minimum 1" Clearance from

Side (Only for See-Thru)

Figure 5 - Minimum Clearances

(See-Thru Shown)

Woodwork, such as wood trims, mantels and other combustible materials should not be placed within 7" of the opening of this fireplace (see Figure 6). Combustible material above projecting more than 11/2" from the appliance’s front face must not be placed less than 15" from the opening of the appli- ance, (ref. NFPA Standard 211 Sec. 7-3.3.3)

Combustible

 

Drywall (Gypsum

Material May

 

Board, Sheetrock, Etc.)

Be Used

 

Safe Zone for

 

 

12" Min.

Projection of

 

 

Combustible

 

 

Material

21" Min.

4"

2 x 4

Spacer

 

Min.

 

 

 

 

15" Min.

 

 

 

 

 

1 1/2" Max.

7" Min.

 

UNIT

 

 

 

Figure 6 - Mantel Clearances for Peninsula and See-Thru Fireplaces (Peninsula Shown)

framing

Once the final location has been determined, ob- serving clearances for the vent termination, you may construct framing using dimensions shown in Figures 7 to 13 depending on your particular installation

If the appliance is to be installed directly on carpeting, tile (other than ceramic), or any combustible mate- rial other than wood flooring, the appliance must be installed upon a metal or wood panel extending the full width and depth of the appliance. There are three holes on each side of the bottom of the unit where screws can be used to secure the unit to the floor.

The gas supply line may be connected through the side framing or alternately through the lower sub- flooring or a platform base if provided (see Figures 10 and 11, page 8). Depending on installation, refer to appropriate illustrations.

" 5/8 23

40

1

 

 

 

 

/

 

 

 

2

39 3/4" Min.

 

 

"

Figure 7 - Rough Opening for Installing

Peninsula Fireplace

" 5/8 23

39 3/4"

Min.

Platform

 

 

 

Must Be

 

 

 

Solid, Flat,

 

 

 

and Fully

40

1

 

Supported

 

 

 

/

 

 

 

2"

 

* As required by design as long as

*

 

ceiling clearance is maintained.

 

Figure 8 - Rough Opening for Installing

Peninsula Fireplace on Platform

56131-Fwww.desatech.com

Page 7
Image 7
Desa TSTA-A(-HA) Continued, Unit, Minimum Clearances See-ThruShown, Rough Opening for Installing, Peninsula Fireplace