Venting Installation

Instructions

Continued

Vertical Termination Configurations Figures 29 through 32 show four different configu- rations for vertical termination. These minimum vertical rises are based on horizontal runs with a minimum of 1/4" upwards pitch per foot ad do not reflect constraints on a vertical system with 45° or greater offset.

Any offset pitch of 45° or less must be considered horizontal and sized within the maximum allow- able lengths listed in the following examples. All connections must be sealed with high temperature silicone sealant as specified in the second warning statement on page 11.

Venting with Two 90° Elbows

Vertical (V) Horizontal (H1) +

 

Horizontal (H2)

5' min.

2' max.

6' min.

4' max.

7' min.

6' max.

8' min.

8' max.

20' max.

8' max.

45° Starter Elbow

Venting with One 90° Elbow

Vertical (V) Horizontal (H)

5' min.

2' max.

6' min.

4' max.

7' min.

6' max.

8' min.

8' max.

20' max.

8' max.

45° Starter Elbow

Note: Install restrictor into inner collar of fireplace as shown.

Figure 30 - Vertical Rigid Venting

Configuration Using One 90° Elbow

Note: Install restrictor into inner collar of fireplace as shown.

Figure 29 - Vertical Rigid Venting

Configuration Using Two 90° Elbows

with Two Horizontal Runs

Note: Install restrictor into inner collar of fireplace as shown.

45° Starter

Elbow

Venting with Two 90° Elbows

Vertical (V1)

Horizontal (H)

5' min.

6' max.

6' min.

12' max.

7' min.

18' max.

8' min.

20' max.

Figure 31 - Vertical Rigid Venting

Configuration Using Two 90° Elbows

18