Venting Installation
Instructions
Continued
Combustible Exterior Wall: For vinyl siding, stucco, or wood exteriors, a siding standoff must be installed between the vent cap and exterior wall. The siding standoff prevents excessive heat from damaging siding materials. Siding materials must be cut to accommodate standoff. Bolt the vent cap to the standoff. Apply
5.Combustible Exterior Wall Only: Slide interior wall firestop over vent pipe before connecting horizontal run to vent cap (see Figure 21).
6.Make final connection to vent terminal.
Flush or recessed with short vent system:
Vent system may be
Make sure the 45° connection at unit is tight and does not come loose before unit is nailed to framing.
Square vent or long vent configuration: Vent pipe must be manipulated at outer end to make final connection. Manually secure pipe inside open framing. If this is a retrofit installation in an inaccessible space, you may have to secure the outer end of vent pipe with wall straps and tap screws at outer end.
When using tap screws with rigid pipe, be sure that screws do not penetrate inner pipe. These procedures may also be followed by flexible pipe installations. To use flexible pipe, vent must be drawn through end firestop, cut back to
Cut Vinyl Siding
Away to Fit Standoff
Standoff
Wood Vent
Screw Cap
Bolt
Apply Mastic
to All Four Sides
Figure 20 - Installing Vinyl Siding Standoff (Combustible Exterior Wall)
Interior Wall Surface
Interior Wall Firestop (Combustible Exterior Wall Only)
Horizontal
Vent Pipe
Screw
Vent Cap
(Horizontal Termination)
Figure 21 - Connecting Vent Cap with
Horizontal Vent Pipe