Desa TPNPEA-A Technical Service, Troubleshooting, Parts Not Under Warranty, Millivolt system

Models: TPNA-A(-HA) TPNPEA-A TPNEA-A TSTPA-A TSTA-A(-HA) TSTPEA-A TPNPA-A TSTEA-A (V)DVF36

1 36
Download 36 pages 57.34 Kb
Page 31
Image 31
Parts Not Under Warranty

Technical Service

Continued

Parts Not Under Warranty

When calling DESA, have ready

Contact authorized dealers of this product. If they

• model number of your fireplace

can’t supply original replacement part(s) call DESA

• the replacement part number

at 1-866-672-6040 for referral information.

 

Troubleshooting

Troubleshooting WARNING: Turn off heater, disconnect power if applicable and let cool before servicing. Only a qualified service person should service and repair heater.

Millivolt system CAUTION: Never use a wire, needle, or similar object to clean pilot. This can damage pilot unit.

Note: The two most common causes of malfunctioning gas appliances are loose wiring connections and construction debris clogging pilot and/or control valve filter.

Note: Before troubleshooting the system make sure gas shut off valve is open.

Millivolt system

 

 

 

 

 

PROBLEM

POSSIBLE CAUSE

REMEDY

Pilot will not light

1.

No gas supply, or shutoff valve

1.

Check to see if you have gas

 

 

2.

is OFF

2.

supply

 

Air in gas line

Hold control valve in the

 

 

 

 

PILOT position for 2 to 3

 

 

 

 

minutes to purge air. If you

 

 

 

 

smell gas stop and wait for a

 

 

 

 

few minutes before trying to

 

3.

Construction debris clogging

3.

light the fireplace

 

Remove debris and dirt, in-

 

 

pilot orifice

 

spect and clean any other

 

4.

Low gas pressure

4.

possible obstructions

 

Contact your gas supplier

 

5.

Control valve knob is not on

5.

Refer to section on pilot

 

6.

the PILOT position

6.

lighting

 

Kinked pilot line

Have a qualified technician

 

7.

Bad valve

7.

replace pilot line

 

Replace control valve (see

 

 

 

 

Replacement Parts and Ac-

 

8.

Bad thermocouple or loose

8.

cesssories, page 34)

 

Tighten thermocouple or re-

 

 

connection

 

place

 

Pilot will not stay lit

1.

Loose wiring on thermopile to

1.

Check wiring connection. Refer

 

 

regulator valve. No millivolt

 

to Wiring Diagrams, page 33

 

 

current being sent to regulator

 

 

 

No gas to burner, although wall

1.

Wall switch wires defective

1.

Check electrical connections

switch and valve are set to the

2.

Thermopile generator or sensor

2.

Re-check problem "Pilot Will

ON position

 

not generating sufficient voltage

 

Not Stay Lit"

 

Frequent pilot outage

1.

Pilot flame may be too low,

1.

Clean and adjust pilot flame for

 

 

causing safety pilot to “drop

 

maximum flame impingement

 

 

out”

 

on thermopile

 

Pilot goes out when wall switch

1.

Millivolt output on thermopile

1.

Replace thermopile

is on

 

too high

 

 

 

56131-F

www.desatech.com

31

Page 31
Image 31
Desa TPNPEA-A Technical Service, Troubleshooting, Parts Not Under Warranty, Millivolt system, Problem, Possible Cause