OPERATING FIREPLACE

Continued

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information beginning on page 29, column 1, before proceeding.

2.Set thermostat to lowest setting (if appli- cable).

3.Turn off wall switch.

4.Open control access panel or louver.

5.Smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information. If you don’t smell gas, go to the next step.

6.The electrode is located by the main burner.

7.Turn main burner wall switch to the ON position for ignition. There will be a spark at the electrode.

8.Replace control access panel or louver once there is a flame at the burner.

If burner will not stay lit after several tries, flip wall switch to OFF and call your service technician or gas supplier.

Specifications

Models (V)DVF36TPNA-(A), (V)DVF36TPNPEA-(A), (V)DVF36TSTA-(A)

AND (V)DVF36TSTEA-(A)

• Input Rating: 35,000/23,300 Btu/Hr

• Fuel: Natural Gas

• Manifold Pressure: 3.5" W.C.

• Minimum Supply Pressure: 4.5 W.C. **

• Maximum Supply Pressure: 10.5" W.C.

• Orifice Size (0-4500 ft.): #34 DMS

Models (V)DVF36TPNPA-(A), (V)DVF36TPNPEA-(A), (V)DVF36TSTP-(A)

AND (V)DVF36TSTPEA-(A)

• Input Rating: 31,000/20,000 Btu/Hr

• Fuel: Propane/LP Gas

• Manifold Pressure: 10.0" W.C.

• Minimum Supply Pressure: 11.0 W.C. **

• Maximum Supply Pressure: 13.0" W.C.

• Orifice Size (0-4500 ft.): #51 DMS **For purpose of input adjustment.

Service Hints

When Gas Pressure Is Too Low

• pilot will not stay lit

• burner will have delayed ignition

• fireplace will not produce specified heat

• propane/LP gas supply may be low

You may feel your gas pressure is too low. If so, contact your local gas supplier.

Technical Service

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA’s

From Gas

 

 

Supply

 

 

 

 

L

 

 

O

 

E

A

Inlet

Outlet

Pressure

 

Pressure

I H

O

 

PIL T

To

 

 

Main

 

Burner

Flame

Adjustment

Knob

Technical Service Department at 1-866-672-6040. When calling, please have your model and serial numbers ready.

You can also visit DESA’s Technical Services web site at www.desatech.com.

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

Figure 61 - Electronic Control Valve

Figure 62 - Electrode

TO TURN OFF GAS

TO APPLIANCE

1.Turn off all electrical power to appliance if service is to be performed.

2.Remove control access panel or louver.

3.Close gas valve.

Parts Under Warranty

Contact authorized dealers of this product. If they can’t supply original replacement part(s) call DESA’s Technical Service Department at 1-866-672-6040 for referral information.

When calling DESA, have ready

• your name • your address

• model and serial numbers of your fireplace

• how fireplace was malfunctioning

• type of gas used (propane/LP or natural gas)

• purchase date

Usually, we will ask you to return the part to the factory.

30

www.desatech.com

56131-F

Page 30