OPERATING GUIDELINES

OPERATING GUIDELINES

AND MAINTENANCE

INSTRUCTIONS

Continued

Cleaning and Replacing Glass Door

Note: Before proceeding, make sure unit is com- pletely cool.

1.Remove top and bottom louvers and screen assembly. Undo 4 latches and open glass door. The procedure is the same for the end lover panel but the entire frame must be removed as one assembly.

2.To clean glass door, DO NOT remove glass from frame. Use any glass cleaner to clean glass. Do not use abrasive cleaners as this may damage glass.

3.If replacement is necessary, the entire assem- bly (frame and glass) must be replaced. If glass is broken, wear gloves and tape remaining fragments onto the frame. Remove 5 screws located on end of firebox while holding frame assembly to prevent it from falling and caus- ing injury (see Figure 57). Mount new frame at hinge with 5 new screws. Close and latch door. This will seat the gasket. If replacing end glass panel, remove 16 screws around frame

(see Figure 58) To insure proper fit, when installing new glass panels make sure seam in gasket is placed in the down position.

4.Replace screen assembly and top and bottom louvers.

Hinge

Figure 57 - Removing Glass Door Screws

Figure 57 - Removing Glass Door

Glass

Assembly

Frame

Assembly

Retainer ScrewsFigure 58 - End Panel ReplacementOperating Fireplace

Louver Assembly Millivolt

Figure 58 - End Panel Replacement

Operating Fireplace

Millivolt

FOR YOUR SAFETY

READ BEFORE LIGHTING

Manual background WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result causing property damage, per- sonal injury or loss of life.

A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service tech- nician or gas supplier. Force or attempted repair may result in a fire or explosion.