Installation
Continued
You may test the blower for operation by turning the control knob clockwise just until it clicks on which is the full on position. Adjust the fan speed to the lowest setting (this should be no more than 1/4 of a turn clockwise).
For Optional
Fan Kit
From Blower
Assembly
Figure 37 - Connecting Blower
Accessory to Power Supply
OPTIONAL Wireless hand-held REMOTE CONTROL Installation
Note: If using an optional wireless
NOTICE: Only use alkaline bat- teries (not included).
Installing HRC100 Model Remote Control (Millivolt Models Only)
1.Remove lower louver access panel in fire- place (see step 1 of Wall Switch Installation, page 21).
2.Disconnect wall switch wires from termi- nals marked TH and TPTH (see Figure 35, page 21).
3.Slide
Plastic Mounting Clips
Gas Receiver Clip
Valve Terminal
Wires
|
| LOT |
|
ON |
| 16AI |
|
OT |
| 7 | TH |
L |
| ||
I |
|
|
|
P |
|
|
|
FFO | L | HI | TP |
| O | ||
E | A |
| TPTH |
|
|
Red | White | |
FRONT | ||
To Thermopoile | ||
|
Figure 38 - Installing Remote Receiver
(HRC100)
4.Connect white wire to control valve terminal TH and red wire to TPTH. Move remote select switch to REMOTE position.
5.Replace louvered access panel by following reverse steps on page 21.
6.Remove battery cover on back of
7.Attach terminal wires to
8.Replace battery cover onto
9.Set selector switch on receiver to OFF posi- tion if you will be away from the unit for an extended period of time.
Battery | Remote Control Unit | |
Cover | ||
Sensor | ||
| ||
| Tag |
Terminal
Wires
Battery
Housing
Figure 39 - Installing Battery in Hand-
Held Remote Control Unit (HRC100)
Installing Skytech/WRC Model Remote Control (Electronic Models Only)
1.Remove lower louver access panel in fire- place (see step 1 of Wall Switch Installation, page 21).
2.If a wall switch was installed, it must be removed from ignition control circuit for remote to work properly. Remove wire nuts from switch connection at ignition control module. Using wire nut, connect transformer (blue) wire to remaining wire connected to control terminal marked P.SW (see Figure 34, page 21).
3.The receiver does not require a battery. To in- stall, plug extension cord into one of the outlet receptacles on the outlet box. Plug receiver unit into extension cord and the ignition module into receiver unit (see Figure 40, page 23).
4.Replace louvered access panel by following reverse steps on page 21.
5.Activate handset battery by removing insulat- ing tab on back (see Figure 41, page 23).
22 | www.desatech.com |