Installation

Continued

 

 

 

 

Optional Fan

Outlet Box

Extension

Kit Plug

Gas

Cord

 

 

Receiver

 

 

 

 

 

 

 

 

 

Valve

 

 

 

 

 

 

 

 

 

 

ILOT

 

 

 

 

 

 

P

 

 

 

O

N

 

16AI

 

 

 

 

 

 

 

 

T

 

 

 

 

 

 

O

 

 

7

TH

 

 

L

 

 

 

 

I

 

 

 

 

 

 

P

 

 

 

 

 

 

FFO

L

I

TP

 

 

 

 

O

White

 

 

 

H

 

 

E

 

A

 

TPTH

Red

To Thermopoile

Figure 40 - Installing Remote Receiver

(SKYTECH Model)

Battery

Cover

12Volt Battery

Pull to Remove

Insulation Tab

IMPORTANT: The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig. (3.5 kPa). The appliance must be isolated from the gas supply piping system by closing its individual equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig. (3.5 kPa).

CAUTION: Do not kink flex- ible gas line.

CAUTION: Compounds used on threaded joints of gas piping shall be resistant to the action of Liquefied Petroleum (LP or propane), and should be applied lightly to ensure excess sealant does not enter the gas line.

1.Install a sediment trap between the incoming gas line and the gas control valve (see Figure 43). The sediment trap should extend down the center of the pipe. Refer to your local codes.

Figure 41 - Installing Battery in Hand-

Held Remote Control Unit (SKYTECH)

GAS LINE HOOK-UP

WARNING: Before you pro- ceed, make sure your gas supply is OFF.

Key

Shutoff Valve

Extension

WARNING: Gas line hookup should be done by your gas supplier or a qualified service person.

An equipment shutoff valve has been included in the appliance’s gas supply system. You may con- sider installing an extra gas shutoff valve outside the appliance’s enclosure (check with local codes) where it can be accessed more conveniently with a key through a wall as shown in Figure 42.

Route a 1/2" NPT black iron gas line towards the appliance coming in from the left. It is recom- mended to route the pipe between the stand of the firebox and the surround of the fireplace (see Figure 43).

Figure 42 - Typical Exterior Wall Gas

Shutoff Installation

Incoming 1/2" Gas

Line Permitted by

Local Codes

Sediment

 

all

Trap (Not

 

 

W

Supplied)

Side

 

Appliance

3" Min.

Of

 

Figure 43 - Sediment Trap