Samsung AR24KQJSBWKNMG manual Fixing the installation plate, When fixing the indoor unit on a wall

Page 45

CAUTION

If you need a pipe longer than specified in piping codes and standards, you must add refrigerant to the pipe. Otherwise, the indoor unit may freeze.

While removing burrs, put the pipe face down to make sure that the burrs do not get in to the pipe.

Step 2.10 Fixing the installation plate

You can install the indoor unit on a wall, window frame, or gypsum board.

WARNING

Make sure that the wall, window frame, or gypsum board can withstand the weight of the indoor unit. If you install the indoor unit in a place where it is not strong enough to withstand the unit's weight, the unit could fall and cause injury.

Liquid service port

Gas service port

<High pressure>

<Low pressure>

When fixing the indoor unit on a wall

Fix the installation plate to the wall giving attention to the weight of the indoor unit.

Plastic anchor

20 mm

Wall

 

A

B

D

C

Correct

Inclined

Cracked

Uneven

Damaged

 

 

thickness

surface

<Flare nut>

 

NOTE

Installation

• Excessive torque may cause gas leakage. When

extending the pipe with welding or brazing, ensure

 

 

that nitrogen is used during the welding or brazing

 

process. The joint must be accessible and serviceable.

 

CAUTION

Tighten the flare nut at the specified torque. If the flare nut is over-tightened, it may break to cause leakage of refrigerant gas.

44English

 

 

 

 

(Unit : mm)

 

 

 

 

 

 

Model

A

B

C

 

D

 

 

 

 

 

 

✴✴18/24✴✴

33

110

110

 

33

 

 

 

 

 

 

 

Pipe bundle hole: Ø 65 mm

NOTE

If you mount the plate to a concrete wall using plastic anchors, make sure that gaps between the wall and the plate, created by projected anchor, is less than 20 mm.

When fixing the indoor unit on a window frame

1Determine the positions of the wooden uprights to be attached to the window frame.

2Attach the wooden uprights to the window frame giving attention to the weight of the indoor unit.

3Attach the installation plate to the wooden upright using tapping screws.

MG_GOOD_R-410A_A3050_IB&IM_EN_ DB68-06070A-00.indd 44

12-May-16 11:29:56 AM

Image 45
Contents Samsung Air conditionergioner Contents Safety Information on Installation Preparation InstallationFor Installation Safety InformationSafety Information For Power Supply For Using Safety Information Safety Information For Cleaning MGGOODR-410AA3050IB&IMEN DB68-06070A-00.indd Display Indoor Unit OverviewInserting batteries Remote Control OverviewRemote Control Operation Controlling temperatureOperation modes Controlling air flow direction Controlling fan speedCool mode Cooling OperationStep cooling function Dehumidifying Operation Dry modeHeating Operation Heat modeQuick Smart Features Auto modeFan mode Fast function Beep sound function Comfort functionSingle user function Energy-Saving OperationTimed on/Timed off function Good’sleep function Running Auto clean Cleaning at a GlanceCleaning the filter Troubleshooting Cleaning and Maintenance Thailand Technical SpecificationsModel AR24KRJSRWK/MG AR24KQJSBWK/MG General information Safety Information on InstallationPower supply line, fuse, or circuit breaker Overview of installation location requirements Choosing the installation locationPreparation Minimum clearances for the outdoor unitPacking and Unpacking Indoor unitOutdoor unit Accessories Checking and preparing accessories and toolsTools Drilling a hole through the wallTaping the pipes, cables, and drain hose Indoor Unit Installation Disassembling the installation plateDisassembling the cover panel Assembly cable Connecting the cablesPrepare a compressor and the following tools Optional Extending the power cable Optional Extending the drain hose Installing and connecting the drain hoseOptional Changing the direction of the drain hose Shortening or extending the refrigerant pipes assembly pipe 10 Fixing the installation plate When fixing the indoor unit on a wallWhen fixing the indoor unit on a window frame 11 Fixing the indoor unit to the installation plate When fixing the indoor unit on a gypsum board12 Assembling the cover panel Connecting the cables and the refrigerant pipes Outdoor Unit InstallationFixing the outdoor unit in place Optional Fixing the outdoor unit to a wall with a rackEvacuating the air Adding refrigerant Installation Inspection Running the Smart Install modePerforming the gas leak tests LED Performing final check and trial operation Pumping down refrigerantPumping down for removing the product