error occurs while reading metadata. A restart from a user termination
First, see if there is a load pending on the table:
$su hpss
$db2
db2> connect to <Database Name> db2> list tablespaces
Scan the output for the table space that corresponds to the table where the failed conversion was performed. Under the table space information, find Detailed explanation. If the Detailed explanation is Normal, perform a restart at this time because there is no load pending. If the Detailed explanation is Load Pending or Quiesced, there is a load pending on the table. Determine what state the load is in. Do this by performing a load query on the table to be restarted:
$su hpss
$db2
db2> connect to <Database Name> db2> load query table <Table Name>
The load query result could be one sentence or several screens worth of SQL messages. Examine the output and try to determine what phase the load is in by finding the last SQL3500 message in the output. At this point, the load will either be in the REBUILD or LOAD phase. The load phase provides information to help understand how to reset the table, if the restart fails and the restart attempt is abandoned. At this point, attempt to perform the restart. The restart on a load pending can take a long time depending on how many records have already been inserted into the table. To check the status of the load, execute a load query command:
$su hpss
$db2
db2> connect to <Database Name> db2> load query table <Table Name>
Run the load query several times in a row to determine if the load is counting records properly. Look at the number next to Number of rows read, it will count up until it reaches the Number of rows loaded and only then will the conversion program continue with normal processing from the last record in the DB2 table. If there is no progress, the program is hung; terminate it and abandon restart procedures.
After abandoning restart procedures, attempt to run the conversion program without the
6.3.13.6. Create Core Server ACLs
Prior to running this conversion program. Ensure you temporarily set the following