Samsung SSA-S3010/EXP manual Duress Mode Output Setup, ARM/DISARM Output Setup

Page 47

DURESS MODE OUTPUT SETUP

You can specify the output time for Duress mode.

1.Press the F5 SETUP MENU button.

2.

Use the buttons 4 and 6

to move to the DURESS ALARM item and

7.DURESS ALARM

 

 

press ENT .

 

 

3.

You can make input when the prompt blinks.

D R

A R

T 1

T 2

B Z

0 0

0 0

0 0

0 0

0 0

 

 

 

Use the keypad to enter the time for each output operation and press ENT .

DR : Door relay output

7.DURESS ALARM

 

AR : Alarm relay output

 

 

 

 

 

 

T1 : TTL #1 output

D R

A R

T 1

T 2

B Z

T2 : TTL #2 output

_ 0

0 0

0 0

0 0

0 0

BZ : Buzzer output

 

 

 

 

 

MDuress Alarm must be enabled (See Page 40 for “Duress Mode”.)

The output time differs, depending on the time unit.

If the time unit is 0.1 (second), you can specify the value between 0.0 and 9.8 second; if set to 1 (second), you can specify between 0 and 98 seconds.

For the time unit, refer to the ‘Time Unit Setup’ under the advanced setup. (see page 54)

If you enter 99 for the value, the product stays in output mode until you change the setting regardless of the time unit.

ARM/DISARM OUTPUT SETUP

You can specify the output time for ARM/DISARM mode.

1.Press the F5 SETUP MENU button.

2.

Use the buttons

4 and

6 to move to the ARM/DISARM SET item

8.ARM/DISARM OUT

 

and press ENT .

 

 

 

 

 

 

 

 

 

 

3.

You can make input when the prompt blinks.

D R

A R

T 1

T 2

B Z

0 0

0 0

0 0

0 0

0 0

 

 

 

 

Use the keypad to enter the time for each output operation and press ENT .

DR : Door relay output

8.ARM/DISARM OUT

AR : Alarm relay output

 

 

 

 

 

T1 : TTL #1 output

D R

A R

T 1

T 2

B Z

T2 : TTL #2 output

_ 0

0 0

0 0

0 0

0 0

BZ : Buzzer output

 

 

 

 

 

MARM/DISARM must be enabled. (See Page 41 for “Arm/Disarm”.)

The output time differs, depending on the time unit.

If the time unit is 0.1 (second), you can specify the value between 0.0 and 9.8 second; if set to 1 (second), you can specify between 0 and 98 seconds.

For the time unit, refer to the ‘Time Unit Setup’ under the advanced setup. (see page 54)

If you enter 99 for the value, the product stays in output mode until you change the setting regardless of the time unit.

English _ 47

I/O TIME SETUP

Image 47
Contents Please visit our website Standalone Biometric Access ControllerSafety information Safety informationThis device may not cause harmful interference, Important Safety InstructionsSafety Information Contents Contents Input Type Setup Event Memory SetupWiegand Output Setup Voice Volume SetupProduct introduction FeaturesDuress Alarm External I/O PinsForced Door Open Alarm Door Open Timeout AlarmQuick Guide CD Manual WHAT’S IncludedLCD AT a GlanceFront Panel LED Communication status indicatorPin Connector Preliminary connector for extension Rear PanelCable Color Scheme PIN ConnectorPins Signal Cable Color Cable Selection TCP/IP RJ45 ConnectorFollow the instructions below to install the wall mount Installing the Wall MountBypass Diode Connection Connecting the Termination Resistor and DiodeEARTH-GROUNDING the Communication Cables Input Connection ConnectionOutput Connection External Reader Connection External Reader ConnectionRS-232 Communication Port Connection Communication Line ConnectionPlease follow the steps below RS-485 Communication Port Connection StandaloneRS-485 Communication Port Connection Multiple Units Max mConnect all RS-485 ports of the product in parallel TCP/IP Communication Port ConnectionInitializing the System Initializing the system using the Initialize switchSystem Initialization in Master Mode InitializationTo register a master card To Access the Master ModeRegistering a Master ID Lift PUT Your Finger To register a master card along with your fingerprintTo register a master card PIN 00/00Not USE Name DisplayTo register a master card PIN along with your fingerprint Language Setup User Count SetupComm Addr SET DATE/TIME SetupCommunication Address Setup SET DATE/TIMEBaud Rate Baud Rate SetupFactory Defaults Default SETREADER#1 Mode ID only JID+F/PP/W Reader mode setupReader #1 Mode Reader #2 ModeReader #2 KEY Input € USE If set, you can get access using the keypad inputRD#1 KEY Input not USE Reader Mode Setup Reader #1 KEY InputDual F/P Mode Jnot USE Dual F/P Mode USE Dual Fingerprint ModeIdentification Jnot USE Adaptive ModeIdentification Mode Adaptive Mode not USE Jnot USE Adaptive Mode USE Mode SetupTo register ID along with fingerprint Registering ID in Quick ModeUser management To register IDPW TA TB C RD MA MB LV FP User Management ID Registered Registering the IDTo register the ID card SSA-S30x1 Numeric letters in 4 ~ 8 or 10 digits To register the ID card along with your fingerprintTo register the PIN number To select PINScreen To Delete IDTo register the PIN number along with your fingerprint Enter PINID List Viewing the ID ListFP REG. Count To Check the Number of Registered FingerprintsALL ID Clear Master ID CLR Duress ModeDuress Mode Not USE Duress Password Enter Duress P/W To delete all registered master IDsARM/DISARM SET Door Open Alarm Time SetupARM/DISARM Open ALR Time User ManagementTo select USE or not USE, and press ENT . J not USE TWO MEN Operation ModeTo move to the TWO MEN Mode item To Check the Number of EventsTo Remove the Time Schedule To Remove ALL EventsExit Button Time setupDoor Contact Sensor Setup Exit Button OutputAUX INPUT#1 Auxiliary Input #1 SetupAuxiliary Input #2 Setup Time SetupCUT OFF Alarm Tamper Alarm Output SetupCUT OFF Output Setup Tamper AlarmARM/DISARM Output Setup Duress Mode Output SetupRD1 ID OK LV1 Door Open Timeout SetupOutput Setup for Level 4 IDs Accessing Reader #1 Output Setup for Level 2 IDs Accessing Reader #1Output Setup for Level 3 IDs Accessing Reader #1 Reader #1 Antipassback Error Output Setup Reader #1 Error Output SetupReader #1 ID Error Output Setup Reader #1 Time Schedule Error Output SetupRD2 ID OK LV2 Output Setup for Level IDS Accessing Reader #212.RD2 ID Error Reader #2 Error Output SetupOutput Setup for Level 4 IDs Accessing Reader #2 Reader #2 ID Error Output Setup14.RD2 APB Error Reader #2 Time Schedule Error Output SetupReader #2 Antipassback Error Output Setup 13.RD2 T/S Error Time SetupTime Unit Unit 1SEC Unit 0.1SEC Advanced setupTime Unit Setup Output Time SCHEDULE+IDUse the 4 Buttons to specify the interval, day Antipassback ModeTime Schedule Setup APB Mode Not USE ALL ClearHoliday Setup Code 10 Holiday Code SetupHoliday Code Code 01RD2 Mode I T/S Reader Mode Time Schedule Reader #1 Mode Time ScheduleReader #2 Mode Time Schedule RD1 Mode I T/ST/S Code ‘00’ means no Time Schedules are to be applied Output Time Schedule SetupVoice Message Time Schedule Voice I T/SCUT OFF SET Input Time Schedule SetupInput CUT OFF Check Setup ID Display Additional featuresEvent Memory Setup Wiegand Output not USE Not USE Wiegand Output SetupVoice Volume Setup Voice VolumeVersion Check  The default setting for One Time Read is not USEONE Time Read Not USE Jnot USE Additional Features ONE Time ReadOutput Test Input TestPress ANY KEY Last UpdateLCD Test Keypad TestReader Test SCANNING… RAM TESTING…Reader Test Memory TestIf the test has succeeded If the test has failed Communication TestFingerprint Module Version Check FailedO , 0 1 N C E X D C I 1 I 2 T P 0 0 0 0 0 0 0 0 0 Input Type SetupInput Type Menu Structure Other informationF4 button Menu Structure of the F3 buttonF3 button Menu Structure of the F4 buttonOther Information Menu Structure of the F5 buttonF5 button F6 button Menu Structure of the F6 buttonMenu Structure of the F8 button Menu Structure of the F7 buttonF10 button Menu Structure of the F9 buttonF9 button Menu Structure of the F10 buttonTTL#1 TTL#2 Default SettingsOutput Settings for Input Sources Duress AlarmOutput Setting for Authentication Trouble Shooting TroubleshootingTroubleshooting Software Buzzer keeps beepingCommunication between Controller and the Host PC failsProduct specifications Product SpecificationsCorrect disposal of batteries in this product