ANTIPASSBACK MODE
Antipassback mode is used to prevent an identical user from entering or exiting the door twice or more consecutively. This mode is available only with an Exit reader dedicated to detecting exits, which is not available in a system that is solely using the Exit button to exit the door.
1. Press the F2 SETUP MENU button.
2. | Use the buttons | 4 | and | 6 | to move to the APB MODE item and press |
| ENT . |
|
|
|
|
3. | Use the buttons | 4 | and | 6 | to select a desired mode and press ENT . |
• NOT USE : The Antipassback mode is disabled.
USE : The
ALL CLEAR! : If entrance or exit is not allowed because of violation of the
5.APB MODE
J NOT USE
5.APB MODE
JUSE
5.APB MODE
J ALL CLEAR!
ADVANCED SETUP
M The Antipass back mode is set to “NOT USE” by default.
You can configure the APB error outputs for each reader on the entrance and exit. (Refer to “Antipassback Error Output Setup” at pages 50 and 53.)
TIME SCHEDULE SETUP
You can set a total of 10 Time Schedule codes. The default code is “00”, which is used to allow unlimited access.
Each Time Schedule code has 8 programmable days (Sunday through Saturday, and a holiday), each of which has 5 time intervals.
You can check information such as Time Schedule code, day of the week, time interval and current Time Schedule setting. A holiday in the Time Schedule is linked to a holiday schedule code.
The Time Schedule is based on
1. Press the F4 SETUP MENU button.
2. | Use the buttons | 4 | and | 6 | to move to the TIME SCHEDULE item and |
|
|
| press ENT . |
|
|
|
| 1.TIME SCHEDULE | |
|
|
|
|
|
| T/S CODE: 10 SAT | |
3. | Use the 4 and | 6 | , 2 | , | 8 buttons to specify the interval, day and | INTERVAL: | 1 |
| code and press ENT . |
|
|
| 00:00 – 00:00 |
|
• T/S CODE : Time Schedule Code 01~10
Weekly : 8 days (HOL,SUN,MON,TUE,WED,THU,FRI,SAT)
INTERVAL : Time interval 1~5
00:00 – 00:00 : hour : min
English _ 55