AMPLIFIER APPLICATIONS
PAB 5400 5-Channel Amplifier
3 way active, with mono bass
The PAB 5400 5 channel amplifier contains all the functions neces- sary to set up a completely self contained 3 way active crossover system.
Interconnect cable checklist:
Use good quality RCA cables to connect the inputs of channels 1&2 to the full range outputs of the source.
Switch setting checklist:
-INPUT MODE: CH2
-CH 1/2
-CH 3/4
Crossover frequency control checklist:
-CH 1/2 HIGH PASS: 1KHz to 4KHz
-CH 3/4 HIGH PASS: 100 Hz
- CH 3/4 LOW PASS: 1KHz to 4KHz
- CH 5 LOW PASS: 100 Hz
Note that the HIGH and LOW PASS controls of channels 3&4 act as the bandpass controls.
Please note that these frequency points are suggestions only. Refer to the loudspeaker manufacturer specifications and the section “Setting up systems after installation for best performance”
Level control checklist:
Refer to the section “Setting up systems after installation for best performance”
Minimum final loudspeaker impedances: 2 ohm per channel
Front/rear high pass, with constant sub bass
Another obvious application for the PAB5400 is to use 4 channels for front/rear satellites, and the mono channel for constant non faded sub bass.
Interconnect cable checklist:
Use good quality RCA cables to connect channels 1,2,3&4 inputs to the front and rear outputs of the source as shown.
Switch setting checklist:
-INPUT MODE: 4CH
-CH 1/2
-CH 3/4
Crossover frequency control checklist:
-CH 1/2 HIGH PASS: 100 Hz
-CH 3/4 HIGH PASS: 100 Hz
-CH 3/4 LOW PASS: N/A
-CH 5 LOW PASS: 100 Hz
Please note that these frequency points are suggestions only. Refer to the loudspeaker manufacturer specifications and the section “Setting up systems after installation for best performance”
Level control checklist:
Refer to the section “Setting up systems after installation for best performance”
Minimum final loudspeaker impedances: 2 ohm per channel
12 |