installation & maintenance
Installation
Safety instructions for the installation
This oven may be installed only by an approved electrician. The installer is responsible for connecting the appliance to the mains and in so doing for observing the relevant safety regulations.
•Ensure protection from live parts when installing the oven.
•The kitchen cabinet in which the oven is built in must satisfy stability requirements as specified in DIN 68930.
Technical specifications |
|
|
|
| 566 |
|
|
|
| 560 | |
Input voltage/Frequency | 230 V ~ 50 Hz |
|
|
| |
Volume (usable capacity) | 66 L |
|
|
|
|
Output rating | max. 3400 W | 595 |
| 572 | |
Net weight | approx. 36 kg |
|
| ||
|
|
| |||
Weight with packaging | approx. 41 kg |
|
|
| |
Housing (W x H x D) | 595 x 595 x 566 mm |
|
|
| |
Oven interior (W x H x D) | 440 x 365 x 405 mm |
| 595 |
| |
|
|
|
| 21 | |
Power connection |
|
|
|
| |
|
|
|
|
| |
If the appliance is not connected to the mains with a plug, a multi- |
|
|
| ||
pole isolator switch (with at least 3 mm contact spacing) must be |
|
|
| ||
provided in order to satisfy safety regulations. The power cable H05 |
|
| |||
|
|
| |||
length to be connected to the oven, even if the oven stands on the |
|
|
| ||
floor in front of its |
|
|
| ||
of the oven with a screwdriver and loosen the screws of the cable |
|
|
| ||
clamp before you connect the power lines to the relevant connection |
|
| |||
terminals. The oven is earthed via the ( |
|
|
|
connected to the mains with a plug, this plug must remain accessible after the oven is installed. Samsung will take no responsibility for accidents that originate from a missing or faulty earth connection.
Installation in the cabinet
This is a
cabinet.min. 550
• Observe minimum distances.
• Fix oven on both sides using screws
After installation, remove the vinyl protective film from the door to the appliance and the protective film from the interior surfaces of the oven.
|
|
| min. 590 |
|
|
|
| max. 600 | min. 50 |
|
|
|
| |
min. 550 | min. 550 |
|
|
|
|
| min. 560 |
| |
|
|
|
| |
min. 600 |
|
|
|
|
min. 50 | min. 600 | min. 50 |
|
|
|
|
| ||
min. 560 | min. 560 |
|
|
|
Airflow | Lower element | Top element |
|
installation & maintenance_15