INSTALLATION

For best performance, mount the fixture about 1.8 meters above the ground.

WARNING: Turn power off at circuit breaker.

1.

Remove

2. Remove

X-Bar.

 

two nuts.

 

 

WIRING

BLACK

WHITE

One Motion Light

BLACKBLACK

WHITE

WHITE

Two Motion Lights

3.Tighten screws finger tight.

SENSITIVITY

MIN MAX

4.Set sensitivity on fixture back to the mid-position.

Twist the junction box wires and the fixture wires together as shown below. Secure with wire connectors. If you have a metal junction box, you may not need the green“pigtail”.If you are unsure about the grounding method, consult your local building code.

5. Attach X-Bar to

junction box

Junction

Box

Due to the size and weight of the fixture, you may find it helpful to have an assistant hold the fixture in place while connecting the wires.

CAUTION: DO NOT connect the RED wire unless you want to control other lights from the motion sensor.

Recommended Grounding Method

Use a green ground “pigtail” (not provided) and twist one end together with the bare fixture wire and the box ground wire. Secure with a wire connector. Secure the other end of the “pigtail” with the GND screw on the X-Bar.

Black to black

White to white

595-5770-05

Image 2
Contents Operation FeaturesMode Switching Summary RequirementsTighten screws finger tight InstallationWiring Black to blackOptional Wiring Tighten nuts Complete the InstallationModel 4193 Glass Installation Turn on the circuit breaker and light switch Avoid locations that will cause Control to seeTroubleshooting Guide If you experience a problem, follow this guideRequisitos FuncionamientoCaracterísticas ADVERTENCIADesconecte la energía en el disyuntor InstalacionResumen de las modalidades del Interruptor Luz de un movimiento CableadoNegro to negro Luz de dos movimientosConexion Alterna Complete LA Instalacion Instalación del vidrio del Modelo 4193Evite lugares que obliguen Al control a ver Prenda el cortacircuitos y el interrup- tor de luzNota El detector tiene un período de cerca Si tiene algún problema siga esta guía Guia DE Investigacion DE AveriasExigences FonctionnementCaractéristique Avertissement Coupez le courant au niveau du disjoncteur Résumé du mode de commutationMinuterie DualBrite Avec les doigtsUne lanterne à détecteur de mouvement CâblageNoir/noir blanc/blanc Deux lanternes à détecteure de mouvementCâblage Facultatif Complétez Linstallation Installation des panneaux de Verre de modèleEssais Éviter de pointer l’appareilGuide DE Dépannage Si vous éprouvez des difficultés, suivre ce guide