TESTING
❒Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1 1/2 minute warm up period before it will detect motion. When first turned on or when switch-
ing modes wait 1 1/2 minutes.
❒Switch the
TEST 1 5 10 MIN | OFF 3 6 DUSK TO |
HOUR DAWN | |
|
Avoid locations that will cause
the control to "see":
•Objects that change temperature rapidly, such as heating vents and air condition- ers. These heat sources could cause false triggering.
•Areas where pets or traffic may trigger the control.
•Nearby large,
180°
6 Ft.
(1.8 m)
30Feet (9.1 m)
Maximum | Maximum |
Range | Coverage Angle |
The detector is less sensitive to motion directly towards it and more sensitive to across motion.
MotionMotion
| Sensor |
Least Sensitive | Most Sensitive |
❒Walk through the coverage area noting where you are when the lights turn on.
❒If you need to change the sensitivity, temporarily remove the fixture and make the adjustment. Too much sensitivity may cause false triggering in some installations.
❒Set the amount of TIME you want the light to stay on after motion is detected. (1, 5, or 10 minutes).
TEST 1 5 10 MIN | OFF 3 6 DUSK TO |
| HOUR DAWN |
❒Set the amount of time after dusk you want the lights on accent level.
SPECIFICATIONS
Range . . . . . . . Up to 30 ft. (9.1 m) [varies with surrounding temperature].
Sensing Angle. . . . Up to 180°
Electrical Load. . . . Up to 100Watt Maximum Incandescent
Sensor Capacity . . . Up to 360 Watt (3.0 A.) Maximum
Power Requirements. . 120 VAC, 60 Hz Operating Modes. . . TEST, AUTO, and
MANUAL MODE Time Delay . . . . . 1, 5, 10 minutes DualBrite® timer . . . Off, 3, 6 hrs, to dawn
The Hampton Bay Lighting Company reserves the right to discontinue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.