Desa CGR65NA, CGR35NA, CGR50BNA Connecting to GAS Supply, Connecting Heater to Utility Gas Line

Page 11

INSTALLING HEATER

Continued

CONNECTING TO GAS SUPPLY

WARNING

A qualified service person must connect heater to gas supply. Follow all local codes.

WARNING

Never connect heater to private (non-utility) gas wells. This gas is commonly known as well-head gas.

IMPORTANT: Check gas line pressure at gas meter before connecting heater to gas line. Gas line pressure must be no greater than 14 inches of water. If gas line pressure is higher, heater regulator damage could occur.

Gas Meter

Figure 6 - Connecting Heater to Utility Gas Line

CAUTION

Use only new, black iron or steel pipe. Internally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe that is 1/2" in diameter or greater to allow proper gas volume to heater. If pipe is too small, undue loss of pressure will occur.

The gas supply line to your heater must be 1/2 inch in diameter or larger. If the supply line branches to serve two or more heaters, the line from the branch back to the gas meter must be doubled or tripled, etc., in size (depending upon the number of heaters). Example for 1/2 inch diameter supply line: If the supply line branches to serve two heaters, the line diameter from the branch back to the gas meter must be at least 1 inch. If three heaters are served, the line diameter from the branch back to the gas meter must be at least 1 1/2 inches.

Note: If gas supply line total length exceeds forty feet, use a larger diameter pipe. Use pipe that is the next size larger than the heater control valve fitting.

11

100792

Image 11
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualFor Your Safety Contents Carbon monoxide poisoning may lead to death Safety InformationSafety Information Identification ProductCheck GAS Type Local Codes Unpacking Product FeaturesInstallation Items Heater Clearances Locating HeaterVenting Heater Do not vent heater in any of the following ways see Figure Venting HeaterVenting Heater Proper Size Vent Connecting Heater to Utility Gas Line Connecting to GAS SupplyGas Connection Checking GAS Connections Pressure Testing Gas Supply Piping SystemLocation of Radiants Installing RadiantsInserting Glass Panels Installing Glass PanelInserting Glass into Lower Retaining Channel AIR for Combustion and Ventilation Draft Hood Spillage Test Determining FRESH-AIR Flow for Heater LocationVentilation Air from Outdoors Example 2 Locating Heater in Confined Closed Area Lighting Instructions For Your Safety Read Before LightingOperating Heater Viewing Pilot Shutting Off Heater Manual Lighting ProcedureBlower Operation To Turn OFF GAS to ApplianceBurner Flame Pattern Inspecting Pilot and Burner FlamePilot Flame Pattern Correct Burner Flame Pattern Cleaning and Maintenance Observed Possible Problem Cause Remedy Trouble ShootingSee Changing Burner See Removing Control TROUBLE- ShootingLighting Instructions Top Ing statement atRemoving Control Valve and Burner Tube Service ProceduresRemoving Burner Changing Burner Orifice Blower Wiring DiagramModel Technical ServiceService Hints 35,000 BTU/Hr 50,000 BTU/HrParts Not Under Warranty Ordering Replacement Parts CentralsParts Under Warranty Valve GA5010 AccessoriesBlower Assembly Illustrated Parts ListCabinet Assembly Burner Assembly Thermocouple Interrupter 100792 100792 Limited Warranty Comfort Glow Vented Natural GAS Heaters Warranty Information