Desa CGR65BNA, CGR35NA, CGR65NA, CGR50BNA, CGR50NA TROUBLE- Shooting, See Removing Control

Page 29

TROUBLE- SHOOTING

Continued

OBSERVED

POSSIBLE

 

 

PROBLEM

CAUSE

REMEDY

 

 

 

 

 

Delayed ignition of

1.

Manifold pressure is

1.

Contact local natural gas

burner.

 

too low.

 

company.

 

2.

Burner orifice is

2.

Clean burner (see

 

 

clogged.

 

Cleaning and Mainte-

 

 

 

 

nance, page 26) or

 

 

 

 

replace burner orifice

 

 

 

 

(see Changing Burner

 

 

 

 

Orifice, page 34).

 

 

 

 

 

Burner backfiring

1.

Burner orifice is

1.

Clean burner (see

during combustion.

 

clogged or damaged.

 

Cleaning and Mainte-

 

 

 

 

nance, page 26) or

 

 

 

 

replace burner orifice

 

 

 

 

(see Changing Burner

 

 

 

 

Orifice, page 34).

 

2.

Burner damaged.

2.

Replace burner.

 

3.

Gas regulator defective.

3.

Replace control valve.

 

4.

Delayed ignition.

4.

See above.

 

 

 

 

 

Yellow flame during

1.

Not enough air.

1.

Check burner for dirt

burner combustion.

 

 

 

and debris. If found,

 

 

 

 

clean burner (see

 

 

 

 

Cleaning and Mainte-

 

 

 

 

nance, page 26).

 

2.

Gas regulator defective.

2.

Replace control valve.

 

 

 

 

 

Flame lifting during

1.

Burner orifice clogged

1.

Clean burner (see

combustion.

 

or damaged.

 

Cleaning and Mainte-

 

 

 

 

nance, page 26) or

 

 

 

 

replace burner orifice

 

 

 

 

(see Changing Burner

 

 

 

 

Orifice, page 34).

 

2.

Manifold pressure too

2.

Replace control valve

 

 

high/defective gas

 

(see Removing Control

 

 

regulator.

 

Valve and Burner Tube,

 

 

 

 

page 32).

 

 

 

 

Slight smoke or odor

1. Residues from manu-

1.

Problem will stop after a

during initial opera-

 

facturing processes.

 

few hours of operation.

tion.

 

 

 

 

 

 

 

 

Continued

29

100792

Image 29
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualFor Your Safety Contents Carbon monoxide poisoning may lead to death Safety InformationSafety Information Identification ProductCheck GAS Type Local Codes Unpacking Product FeaturesInstallation Items Heater Clearances Locating HeaterVenting Heater Do not vent heater in any of the following ways see Figure Venting HeaterVenting Heater Proper Size Vent Connecting Heater to Utility Gas Line Connecting to GAS SupplyGas Connection Checking GAS Connections Pressure Testing Gas Supply Piping SystemLocation of Radiants Installing RadiantsInserting Glass Panels Installing Glass PanelInserting Glass into Lower Retaining Channel AIR for Combustion and Ventilation Draft Hood Spillage Test Determining FRESH-AIR Flow for Heater LocationVentilation Air from Outdoors Example 2 Locating Heater in Confined Closed Area Lighting Instructions For Your Safety Read Before LightingOperating Heater Viewing Pilot Blower Operation Manual Lighting ProcedureTo Turn OFF GAS to Appliance Shutting Off HeaterBurner Flame Pattern Inspecting Pilot and Burner FlamePilot Flame Pattern Correct Burner Flame Pattern Cleaning and Maintenance Observed Possible Problem Cause Remedy Trouble ShootingSee Changing Burner See Removing Control TROUBLE- ShootingLighting Instructions Top Ing statement atRemoving Control Valve and Burner Tube Service ProceduresRemoving Burner Changing Burner Orifice Blower Wiring DiagramService Hints Technical Service35,000 BTU/Hr 50,000 BTU/Hr ModelParts Not Under Warranty Ordering Replacement Parts CentralsParts Under Warranty Valve GA5010 AccessoriesBlower Assembly Illustrated Parts ListCabinet Assembly Burner Assembly Thermocouple Interrupter 100792 100792 Limited Warranty Comfort Glow Vented Natural GAS Heaters Warranty Information