TROUBLE- SHOOTING
Continued
WARNING
WARNING ICON | G 001 |
If you smell gas
•Shut off gas supply.
•Do not try to light any appliance.
•Do not touch any electrical switch; do not use any phone in your building.
•Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
•If you cannot reach your gas supplier, call the fire department.
OBSERVED | POSSIBLE | REMEDY | ||
PROBLEM | CAUSE | |||
|
|
|
|
|
Heater produces | 1. | Heater burning vapors | 1. | Ventilate room. Stop |
unwanted odors. |
| from paint, hair spray, |
| using odor causing |
|
| glues, etc. |
| products while heater is |
| 2. | Gas leak. See Warn- |
| running. |
|
| ing statement at | 2. | Find and correct all |
|
| top of page. |
| leaks (see Checking Gas |
|
|
|
| Connections, page 13). |
|
|
|
|
|
Heater shuts off in | 1. | Heater not venting | 1. | Check venting system. |
use. |
| correctly. Vent safety |
| If damaged or blocked, |
|
| switch shuts off |
| repair. If venting |
|
| heater. |
| system is OK, have |
|
|
|
| qualified service person |
|
|
|
| replace vent safety |
|
|
|
| switch, wire harness, or |
|
|
|
| thermocouple inter- |
|
|
|
| rupter. |
| 2. | Low line pressure. | 2. | Contact local natural |
|
|
|
| gas company. |
| 3. | Pilot partially clogged. | 3. | Clean pilot (see Clean- |
|
|
|
| ing and Maintenance, |
|
|
|
| page 26). |
|
|
|
|
|
Gas odor even when | 1. | Gas leak. See Warn- | 1. | Find and correct all |
control knob is in |
| ing statement at |
| leaks (see Checking Gas |
OFF position. |
| top of page. |
| Connections, page 13). |
| 2. | Control valve damaged. | 2. | Replace control valve. |
|
|
|
|
|
Gas odor during | 1. | Foreign matter be- |
combustion. |
| tween control valve |
|
| and burner. |
| 2. | Gas leak. See Warn- |
|
| ing statement at |
|
| top of page. |
| 3. | Foreign fumes in area |
|
| of heater being drawn |
|
| through burner com- |
|
| bustion. |
1.Take apart gas tubing and remove foreign matter.
2.Find and correct all leaks (see Checking Gas Connections, page 13).
3.Ventilate area around heater to remove any foreign fumes.
31
100792