Desa CGR50BNA, CGR35NA, CGR65NA, CGR50NA Service Procedures, Removing Control Valve and Burner Tube

Page 32

SERVICE PROCEDURES

Removing Control Valve and Burner Tube

1.Shut off gas supply to heater.

2.Remove lower front access panel on heater.

3.Disconnect burner tube from orifice holder (see Figure 23).

4.Remove pilot gas line from control valve (see Figure 23).

5.Disconnect wire connec- tors from thermocouple interrupter (see Figure 23).

6.Remove thermocouple and thermocouple inter- rupter from control valve.

7.Remove cotter pin from control valve. This releases the control rod from valve (see Figure 23).

8.Remove the two mounting screws from control valve mounting bracket (see Figure 23).

9.Remove assembly from the rear of heater.

10.To reinstall, reverse above steps. Turn on gas to heater and check for gas leaks. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

11.Replace lower front access panel.

32

WARNING

Turn off and unplug heater and let cool before servicing. Unless you need gas supply for testing, shut off manual shutoff valve before servicing. Only a qualified service person should service and repair heater and venting system.

Control Rod

Cotter Pin

Control Valve

Control Valve

 

Bracket

 

 

 

Mounting

Orifice

 

Screw

 

 

Holder

Burner

 

 

Wire Connector

 

Tube

Thermocouple

Interrupter

Thermocouple

Pilot Gas Line

Wire Connector

Figure 23 - Removing Control Valve and Burner Tube

100792

Image 32
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualFor Your Safety Contents Safety Information Carbon monoxide poisoning may lead to deathSafety Information Product IdentificationCheck GAS Type Local Codes Unpacking Product FeaturesInstallation Items Locating Heater Heater ClearancesVenting Heater Venting Heater Do not vent heater in any of the following ways see FigureVenting Heater Proper Size Vent Connecting to GAS Supply Connecting Heater to Utility Gas LineGas Connection Pressure Testing Gas Supply Piping System Checking GAS ConnectionsInstalling Radiants Location of RadiantsInstalling Glass Panel Inserting Glass PanelsInserting Glass into Lower Retaining Channel AIR for Combustion and Ventilation Determining FRESH-AIR Flow for Heater Location Draft Hood Spillage TestVentilation Air from Outdoors Example 2 Locating Heater in Confined Closed Area Lighting Instructions For Your Safety Read Before LightingOperating Heater Viewing Pilot Manual Lighting Procedure Blower OperationTo Turn OFF GAS to Appliance Shutting Off HeaterBurner Flame Pattern Inspecting Pilot and Burner FlamePilot Flame Pattern Correct Burner Flame Pattern Cleaning and Maintenance Trouble Shooting Observed Possible Problem Cause RemedySee Changing Burner TROUBLE- Shooting See Removing ControlLighting Instructions Ing statement at TopService Procedures Removing Control Valve and Burner TubeRemoving Burner Blower Wiring Diagram Changing Burner OrificeTechnical Service Service Hints35,000 BTU/Hr 50,000 BTU/Hr ModelParts Not Under Warranty Ordering Replacement Parts CentralsParts Under Warranty Accessories Valve GA5010Illustrated Parts List Blower AssemblyCabinet Assembly Burner Assembly Thermocouple Interrupter 100792 100792 Warranty Information Limited Warranty Comfort Glow Vented Natural GAS Heaters