Desa CGR65NA, CGR35NA, CGR50BNA, CGR50NA, CGR65BNA Inserting Glass into Lower Retaining Channel

Page 16

INSTALLING HEATER

Continued

6. Insert top edge of glass panel into the upper glass retaining channel (see Figure 12).

CAUTION

WARNING ICON

G 001

Make sure you insert top edge of glass panels into the upper glass retaining channel. Do not install glass panels with top edge of glass in front of the upper glass retaining channel. Glass panels will not automatically go into the channel. You must guide the glass panels into it. Incorrect installation will damage front of heater due to excess temperatures.

Upper Glass

Retaining Channel

Lower Glass

Retaining Channel

Lower Front Access Area

1

Glass

Panel

2

16

Figure 12 - Inserting Top Edge of Glass Panel into

Upper Glass Retaining Channel

7.Lower glass into lower glass retaining channel. Slide glass panel all the way to the left side.

Note: If you have chipped or cracked a glass panel during installation, do not use. Contact DESA International’s Technical Service Department at 1-800- 323-5190 for a replacement glass panel.

Glass

Panel 1

Lower Glass

Retaining

Channel

2

Figure 13 - Inserting Glass into Lower Retaining Channel

8.Repeat steps 4 through 7 for all glass panels.

9.Reinstall glass guard. Reinstall lower front access panel of heater.

100792

Image 16
Contents For Your Safety OWNER’S Operation and Installation ManualWhat to do if YOU Smell GAS Contents Safety Information Carbon monoxide poisoning may lead to deathSafety Information Product IdentificationInstallation Items Local Codes Unpacking Product FeaturesCheck GAS Type Locating Heater Heater ClearancesVenting Heater Venting Heater Do not vent heater in any of the following ways see FigureVenting Heater Proper Size Vent Connecting to GAS Supply Connecting Heater to Utility Gas LineGas Connection Pressure Testing Gas Supply Piping System Checking GAS ConnectionsInstalling Radiants Location of RadiantsInstalling Glass Panel Inserting Glass PanelsInserting Glass into Lower Retaining Channel AIR for Combustion and Ventilation Determining FRESH-AIR Flow for Heater Location Draft Hood Spillage TestVentilation Air from Outdoors Example 2 Locating Heater in Confined Closed Area Operating Heater For Your Safety Read Before LightingLighting Instructions Viewing Pilot Manual Lighting Procedure Blower OperationTo Turn OFF GAS to Appliance Shutting Off HeaterPilot Flame Pattern Inspecting Pilot and Burner FlameBurner Flame Pattern Correct Burner Flame Pattern Cleaning and Maintenance Trouble Shooting Observed Possible Problem Cause RemedySee Changing Burner TROUBLE- Shooting See Removing ControlLighting Instructions Ing statement at TopService Procedures Removing Control Valve and Burner TubeRemoving Burner Blower Wiring Diagram Changing Burner OrificeTechnical Service Service Hints35,000 BTU/Hr 50,000 BTU/Hr ModelParts Under Warranty Ordering Replacement Parts CentralsParts Not Under Warranty Accessories Valve GA5010Illustrated Parts List Blower AssemblyCabinet Assembly Burner Assembly Thermocouple Interrupter 100792 100792 Warranty Information Limited Warranty Comfort Glow Vented Natural GAS Heaters