Quadra-Fire QFP44 owner manual Clear Space, Decorative Doors and Fronts, Fixed Glass Assembly

Page 10

C. Clear Space

WARNING! DO NOT place combustible objects in front of the replace or block louvers. High temperatures may start a re. See Figure 2.2.

Avoid placing candles and other heat-sensitive objects on mantel or hearth. Heat may damage these objects.

 

Clear Space

 

3 ft (0.91 m)

 

in front of

 

appliance

Figure 2.2

Clear Space

D. Decorative Doors and Fronts

WARNING! Risk of Fire! Install ONLY doors or fronts approved by Hearth & Home Technologies. Unapproved doors or fronts may cause replace to overheat.

￿This appliance requires the installation of a decorative front with an integral barrier to prevent direct contact with the xed glass panel. Do NOT operate the appliance with the barrier removed.

Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one.

For more information refer to the instructions supplied with your decorative door or front.

E. Fixed Glass Assembly

See Section 14.A.

F. Dashboard Control

Figure 2.3 Dashboard Control

Valve Control

This knob is used to control the gas to the appliance and for starting the pilot. There are three positions, ON, OFF, PILOT. The indicator on the valve indicates the position of the knob.

Pilot Ignitor

This unit is equipped with an electronic ignitor for the pilot. When the valve control knob is turned to the PILOT position and fully depressed, the ignitor will begin spark- ing and light the pilot. After the pilot is lit, release the knob slightly to stop the ignitor from sparking but continue holding the knob in for 30 seconds to establish the pilot. Release the knob and the pilot should stay lit.

Rear Burner Switch

The rear burner can be shut off completely with the switch, allowing the front burner to operate in either high or low mode for limited heat output.

10

Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08

Image 10
Contents Models Installation and OperationWhat to do if you smell gas Congratulations Homeowner Reference InformationInstaller Guide Table of ContentsUser Guide Troubleshooting CONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Operating Instructions Gas Fireplace SafetyYour Fireplace Decorative Doors and Fronts Fixed Glass AssemblyClear Space Dashboard ControlRemote Operation Ignitor Battery BoxCanadian Equipment Requirements Remote Receiver TransmitterMatching Security Codes Transmitter SettingsSetting the Clock Operating InstructionsSetting the Countdown Timer Setting F/C ScaleSetting Desired Room Temperature Ther- mo Operations Operating the Fan Operates in on or THER- MO modeTransmitter Safety Features Adjusting the Flame Height Operates in on or Thermo modeLow/Battery Indicator Thermo-Updating and Communication-Safety FeaturesBefore Lighting Fireplace Timer OperationBattery Life General Information Transmitter Wall BracketFor Your Safety Read Before Lighting Lighting Instructions SPInitial Break-in Procedure Frequently Asked QuestionsAfter Fireplace is Lit Glass Cleaning Maintenance and ServiceMaintenance Tasks-Homeowner Remote ControlMaintenance Tasks-Quali ed Service Technician Standing Pilot Flame Patterns Getting Started Typical Appliance SystemTools and Supplies Needed Design and Installation ConsiderationsInspect Appliance and Components Framing and Clearances Select Appliance LocationConstruct the Appliance Chase ClearancesMantels Mantel and Wall ProjectionsMantel Legs or Wall Projections Termination Locations Vent Termination Minimum ClearancesMinimum Clearances for Termination Vent Table Key Vent Information and DiagramsApproved Pipe Use of ElbowsTop Vent Horizontal Termination Vent DiagramsOne Elbow Two 45 Elbows replacing One 90 Elbow Three ElbowsNo Elbow Top Vent Vertical TerminationTwo Elbows 12 ft 3.66 m min 60 ft 18.29 m max Wall Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Combustible Wall PenetrationInstall the Ceiling Firestop Installing Ceiling FirestopFlat Ceiling Installation Install Attic Insulation ShieldVaulted Ceiling Installation Appliance Preparation Secure and Level the ApplianceAssemble Vent Sections Install Vent PipeAttach Pipe to the Firebox Assembly Assemble Pipe SectionsAssemble Slip Sections Slip Section Pilot HolesSecure the Vent Sections Disassemble Vent SectionsInstall Metal Roof Flashing CaulkAssemble and Install Storm Collar 13 Assembling the Storm CollarInstall RF4-8 Apply Sealant Top & Partial SidesInstall Vertical Termination Cap Heat Shield Requirements for Horizontal TerminationInstall Horizontal Termination Cap 20 Venting through the wallFuel Conversion Kit contentsGas Information Converting to LP Gas44CKP Gas Pressure Gas ConnectionOptional Accessories Requirements Wiring RequirementsStanding Pilot Ignition System Wiring Electrical InformationElectrical Service and Repair Junction Box InstallationFinishing Mantel Leg or Perpendicular WallFacing Template Removal Facing MaterialMantel Install the Refractory Appliance SetupRemove Glass Assembly Clean the ApplianceAdjust the Air Shutter Install Upper Back RefractoryAdjust the Vertical Baf e Install Logs, Ember Bed & Rockwool12 Positioning Right Front Leg Install Door Fronts Install Andirons Reinstall GlassPlace Lava Rock and Vermiculite Troubleshooting Standing Pilot Ignition SystemTroubleshooting Symptom Possible Cause Corrective ActionAppliance Dimension Diagram Reference MaterialsVent Components Diagrams DVP45BEK DVP-BEK2 DVP-TVHW DVP-TRAP Service PartsService Parts Description Serial # Part NumberOptional Components Contact Information

QFP44 specifications

The Quadra-Fire QFP44 is a highly efficient and versatile pellet stove designed to provide warmth and comfort while offering a range of advanced features and technologies. It stands out in the market for its blend of efficiency, user-friendly operation, and aesthetic appeal.

One of the key features of the QFP44 is its impressive heat output. With a heating capacity of up to 2,500 square feet, it is suitable for medium to larger living spaces, making it an ideal choice for families looking for an effective heating solution. The stove boasts an adjustable output, allowing users to set the heat level according to their specific needs, which promotes energy efficiency and enhances comfort.

The QFP44 utilizes a patented feed system that ensures a consistent and reliable supply of pellets for combustion. This technology not only maximizes fuel efficiency but also minimizes the need for frequent refueling. In addition, the stove features a large hopper capacity, capable of holding up to 45 pounds of pellets. This translates into longer burn times, enabling users to enjoy hours of warmth without constant supervision.

Another notable characteristic of the QFP44 is its advanced control system. The innovative electronic control board allows users to monitor and adjust the stove settings easily. The system includes programmable temperature settings, which enable homeowners to schedule heating times according to their lifestyle. This convenience makes the stove ideal for those who want to return to a warm home without wasting energy.

The QFP44 is also engineered with a clean-burning technology that significantly reduces emissions. This feature not only makes the stove environmentally friendly but also enhances its safety profile. The high-efficiency combustion system effectively converts pellets into heat with minimal smoke and pollutants, fulfilling strict environmental standards.

For aesthetic appeal, the QFP44 is designed with a contemporary look, featuring a large viewing window that allows users to enjoy the beautiful ambiance of the flame. The stove is available in various finishes, making it a stylish addition to any home décor.

Overall, the Quadra-Fire QFP44 combines efficiency, user-friendly technology, and an elegant design, making it a top choice for anyone seeking an effective and attractive pellet heating solution. Its blend of features ensures homeowners can enjoy both comfort and convenience during the cold months while maintaining an environmentally responsible heating option.