Quadra-Fire QFP44 Adjusting the Flame Height Operates in on or Thermo mode, Low/Battery Indicator

Page 15

Adjusting the Flame Height -

Operates in ON or THERMO mode

This remote control system allows the user to control the height of the FLAME when the gas valve is factory equipped with a FLAME CONTROLLER.

• Press and release FLAME button to change ame height to HI (see Figure 2.6, Location #5), a second ame icon appears.

Press again to return ame to normal state.

Low/Battery Indicator

An “X” outlined by a battery on the right side of the LCD screen will appear when battery power has dropped sig- ni cantly. At this time, approximately two weeks of battery power remains.

Child Proof Lockout (CP)

The transmitter contains a “Child Proof” lockout feature that prevents unauthorized use of the remote control. To access the “Child Proof” activation button, remove cover on BACK of transmitter. To activate LOCKOUT:

Press and hold in the “setting button” for 5 seconds (see Figure 2.7). The letters CP will display on the LCD screen). This prevents the activation of replace. When any function button is pressed ON/OFF etc. the letter CP will display on the LCD screen.

To deactivate LOCKOUT:

Press and hold in the “setting button” for 5 seconds. The LCD will display CP until 5 seconds have elapsed, and then the LCD screen will return to its normal state.

Transmitter Safety Features

It is recommended that the TRANSMITTERS always be located within a 20 foot operating range of the replace, preferably in the same room in which the replace system is located. The TRANSMITTER features several safety features that alert the user when the TRANSMITTER is placed outside the 20 foot normal operating range.

Thermo-Updating and Communication-Safety Features

This remote control has a COMMUNICATION-SAFETY function built into its software. It provides an extra margin of safety when the TRANSMITTER is out of the normal

20 foot operating range of the receiver. It is also activated when the batteries become weak or are removed from the transmitter.

In the THERMO-UPDATING feature (only in the THER- MO or TIMER modes) the transmitter normally reads the ROOM temperature every 2 minutes. In addition to check- ing the temperature, the transmitter sends a signal to the receiver indicating that the transmitter and its batteries are still active.

In the COMMUNICATION-SAFETY feature, at all times and in all OPERATING MODES the transmitter sends a

signal every 15 minutes to the receiver, indicating that the transmitter is within the normal operating range of 20 feet.

Should the receiver NOT receive a transmitter signal every 15 minutes (COMMUNICATION-SAFETY feature), the RECEIVER will begin a 2 HOUR (120 minute) count- down timing function. If during this 2 hour period, the re- ceiver does not receive a signal from the transmitter, the RECEIVER will shut down the replace being controlled by the receiver. The RECEIVER will then emit a series of rapid “beeps”. Then, after 10 rapid “beeps”, the RECEIV- ER will continue to emit a single “beep” every 4 seconds until a transmitter signal is again received. The intermit- tent 4 second beeping will go on inde nitely until reset.

To “reset” the RECEIVER and operate the replace sys- tem:

Press the MODE button on the transmitter. The word ON must display on the LCD screen. The COMMUNICATION -SAFETY operation is overridden and the system will return to normal operation depending on the MODE selected at the transmitter. We recommend the user check the batteries in the TRANSMITTER to make sure the voltage is no less than 2.7 volts.

Auto Shutdown

This remote control has an Auto Shutdown feature incor- porated into its system. When the transmitter MODE is in the ON position the replace will continuously operate for 9 hours. After 9 hours, the replace will shut down. To relight the replace:

Press the MODE button. The replace will operate continuously for up to 9 hours before Auto Shutdown repeats cycle. The Auto Shutdown signal comes from the transmitter. The transmitter must be positioned within a 20 ft operating range for the Auto Shutdown feature to operate.

System Check

Light the appliance following the lighting instructions that came with the replace. Con rm that the pilot ame is on. It must be in operation for the main gas valve to operate.

Slide the 3-position button on the remote receiver to the ON position. The main gas ame (i.e., the re) should ignite.

Slide the button to OFF. The ame should extinguish (the pilot ame will remain on).

Slide the button to REMOTE (the center position), then press the MODE button on the transmitter to change the system to ON. The main gas ame should ignite.

Press the MODE button on the transmitter to change the system to OFF. The ame should extinguish (the pilot ame will remain on).

Press the MODE button on the transmitter to change the system to THERMO.

Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08

15

Image 15
Contents Installation and Operation ModelsWhat to do if you smell gas Homeowner Reference Information CongratulationsTable of Contents Installer GuideUser Guide Troubleshooting CONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Gas Fireplace Safety Operating InstructionsYour Fireplace Dashboard Control Fixed Glass AssemblyClear Space Decorative Doors and FrontsIgnitor Battery Box Remote OperationCanadian Equipment Requirements Transmitter Remote ReceiverOperating Instructions Transmitter SettingsSetting the Clock Matching Security CodesOperating the Fan Operates in on or THER- MO mode Setting F/C ScaleSetting Desired Room Temperature Ther- mo Operations Setting the Countdown TimerThermo-Updating and Communication-Safety Features Adjusting the Flame Height Operates in on or Thermo modeLow/Battery Indicator Transmitter Safety FeaturesGeneral Information Transmitter Wall Bracket Timer OperationBattery Life Before Lighting FireplaceLighting Instructions SP For Your Safety Read Before LightingFrequently Asked Questions Initial Break-in ProcedureAfter Fireplace is Lit Remote Control Maintenance and ServiceMaintenance Tasks-Homeowner Glass CleaningMaintenance Tasks-Quali ed Service Technician Standing Pilot Flame Patterns Typical Appliance System Getting StartedDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Select Appliance Location Framing and ClearancesClearances Construct the Appliance ChaseMantel and Wall Projections MantelsMantel Legs or Wall Projections Vent Termination Minimum Clearances Termination LocationsMinimum Clearances for Termination Use of Elbows Vent Information and DiagramsApproved Pipe Vent Table KeyVent Diagrams Top Vent Horizontal TerminationOne Elbow Three Elbows Two 45 Elbows replacing One 90 ElbowTop Vent Vertical Termination No ElbowTwo Elbows 12 ft 3.66 m min 60 ft 18.29 m max Combustible Wall Penetration Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration FramingInstalling Ceiling Firestop Install the Ceiling FirestopInstall Attic Insulation Shield Flat Ceiling InstallationVaulted Ceiling Installation Secure and Level the Appliance Appliance PreparationAssemble Pipe Sections Install Vent PipeAttach Pipe to the Firebox Assembly Assemble Vent SectionsSlip Section Pilot Holes Assemble Slip SectionsDisassemble Vent Sections Secure the Vent SectionsCaulk Install Metal Roof Flashing13 Assembling the Storm Collar Assemble and Install Storm CollarApply Sealant Top & Partial Sides Install RF4-8Heat Shield Requirements for Horizontal Termination Install Vertical Termination Cap20 Venting through the wall Install Horizontal Termination CapConverting to LP Gas Kit contentsGas Information Fuel Conversion44CKP Gas Connection Gas PressureElectrical Information Wiring RequirementsStanding Pilot Ignition System Wiring Optional Accessories RequirementsJunction Box Installation Electrical Service and RepairMantel Leg or Perpendicular Wall FinishingFacing Material Facing Template RemovalMantel Clean the Appliance Appliance SetupRemove Glass Assembly Install the RefractoryInstall Upper Back Refractory Adjust the Air ShutterInstall Logs, Ember Bed & Rockwool Adjust the Vertical Baf e12 Positioning Right Front Leg Install Andirons Reinstall Glass Install Door FrontsPlace Lava Rock and Vermiculite Standing Pilot Ignition System TroubleshootingSymptom Possible Cause Corrective Action TroubleshootingReference Materials Appliance Dimension DiagramDVP45 Vent Components DiagramsBEK DVP-BEK2 DVP-TVHW DVP-TRAP Parts ServiceDescription Serial # Part Number Service PartsOptional Components Contact Information

QFP44 specifications

The Quadra-Fire QFP44 is a highly efficient and versatile pellet stove designed to provide warmth and comfort while offering a range of advanced features and technologies. It stands out in the market for its blend of efficiency, user-friendly operation, and aesthetic appeal.

One of the key features of the QFP44 is its impressive heat output. With a heating capacity of up to 2,500 square feet, it is suitable for medium to larger living spaces, making it an ideal choice for families looking for an effective heating solution. The stove boasts an adjustable output, allowing users to set the heat level according to their specific needs, which promotes energy efficiency and enhances comfort.

The QFP44 utilizes a patented feed system that ensures a consistent and reliable supply of pellets for combustion. This technology not only maximizes fuel efficiency but also minimizes the need for frequent refueling. In addition, the stove features a large hopper capacity, capable of holding up to 45 pounds of pellets. This translates into longer burn times, enabling users to enjoy hours of warmth without constant supervision.

Another notable characteristic of the QFP44 is its advanced control system. The innovative electronic control board allows users to monitor and adjust the stove settings easily. The system includes programmable temperature settings, which enable homeowners to schedule heating times according to their lifestyle. This convenience makes the stove ideal for those who want to return to a warm home without wasting energy.

The QFP44 is also engineered with a clean-burning technology that significantly reduces emissions. This feature not only makes the stove environmentally friendly but also enhances its safety profile. The high-efficiency combustion system effectively converts pellets into heat with minimal smoke and pollutants, fulfilling strict environmental standards.

For aesthetic appeal, the QFP44 is designed with a contemporary look, featuring a large viewing window that allows users to enjoy the beautiful ambiance of the flame. The stove is available in various finishes, making it a stylish addition to any home décor.

Overall, the Quadra-Fire QFP44 combines efficiency, user-friendly technology, and an elegant design, making it a top choice for anyone seeking an effective and attractive pellet heating solution. Its blend of features ensures homeowners can enjoy both comfort and convenience during the cold months while maintaining an environmentally responsible heating option.