Quadra-Fire QFP44 Install Vent Pipe, Assemble Vent Sections, Attach Pipe to the Firebox Assembly

Page 38

10 Install Vent Pipe

A. Assemble Vent Sections

Attach Pipe to the Firebox Assembly

Note: The end of the pipe sections with the lanced tabs will face towards the appliance.

Attach the rst pipe section to the starting collar:

Lanced pipe end to the starting collar

Inner pipe over inner collar

Push the pipe section until all lanced tabs snap in place

Lightly tug on pipe to con rm it has locked.

Commercial, Multi-family (Multi-level exceeding two stories), or High-Rise Applications

All outer pipe joints must be sealed with high temperature silicone, including the slip section that connects directly to the horizontal termination cap.

Apply a bead of silicone sealant inside the female outer pipe joint prior to joining sections. See Figure 10.1

Only outer pipes need to be sealed. All unit collar, pipe, slip section, elbow and cap outer ues shall be sealed in this manner, unless otherwise stated.

WARNING! Risk of Fire or Explosion! DO NOT break

silicone seals on slip sections. Use care when removing termination cap from slip pipe. If slip section seals are bro- ken during removal of the termination cap, vent may leak.

Figure 10.1 High Temperature Silicone Sealant

A

Lances

B

Figure 10.2

Figure 10.3

Assemble Pipe Sections

Per Figure 10.2:

Start the inner pipe on the lanced end of section A into the ared end of section B.

Start the outer pipe of section A over the outer pipe of section B.

Once both vents sections are started, push rmly until all lanced tabs lock into place.

Lightly tug on the pipe to confirm the tabs have locked.

It is acceptable to use screws no longer than 1/2 in. (13

mm)to hold outer pipe sections together. If predrilling holes, DO NOT penetrate inner pipe.

For 90° and 45° elbows that are changing the vent direction from horizontal to vertical, one screw minimum should be put in the outer ue at the horizontal elbow joint to prevent the elbow from rotating. Use screws no longer than 1/2 in. (13 mm). If predrilling screw holes, DO NOT penetrate inner pipe.

Note: Make sure that the seams are not aligned to prevent unintentional disconnection.

CORRECT

INCORRECT

Figure 10.4 Seams

38

Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08

Image 38
Contents What to do if you smell gas Installation and OperationModels Congratulations Homeowner Reference InformationUser Guide Table of ContentsInstaller Guide Troubleshooting CONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Your Fireplace Gas Fireplace SafetyOperating Instructions Decorative Doors and Fronts Fixed Glass AssemblyClear Space Dashboard ControlCanadian Equipment Requirements Ignitor Battery BoxRemote Operation Remote Receiver TransmitterMatching Security Codes Transmitter SettingsSetting the Clock Operating InstructionsSetting the Countdown Timer Setting F/C ScaleSetting Desired Room Temperature Ther- mo Operations Operating the Fan Operates in on or THER- MO modeTransmitter Safety Features Adjusting the Flame Height Operates in on or Thermo modeLow/Battery Indicator Thermo-Updating and Communication-Safety FeaturesBefore Lighting Fireplace Timer OperationBattery Life General Information Transmitter Wall BracketFor Your Safety Read Before Lighting Lighting Instructions SPAfter Fireplace is Lit Frequently Asked QuestionsInitial Break-in Procedure Glass Cleaning Maintenance and ServiceMaintenance Tasks-Homeowner Remote ControlMaintenance Tasks-Quali ed Service Technician Standing Pilot Flame Patterns Getting Started Typical Appliance SystemInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Framing and Clearances Select Appliance LocationConstruct the Appliance Chase ClearancesMantel Legs or Wall Projections Mantel and Wall ProjectionsMantels Termination Locations Vent Termination Minimum ClearancesMinimum Clearances for Termination Vent Table Key Vent Information and DiagramsApproved Pipe Use of ElbowsOne Elbow Vent DiagramsTop Vent Horizontal Termination Two 45 Elbows replacing One 90 Elbow Three ElbowsTwo Elbows Top Vent Vertical TerminationNo Elbow 12 ft 3.66 m min 60 ft 18.29 m max Wall Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Combustible Wall PenetrationInstall the Ceiling Firestop Installing Ceiling FirestopVaulted Ceiling Installation Install Attic Insulation ShieldFlat Ceiling Installation Appliance Preparation Secure and Level the ApplianceAssemble Vent Sections Install Vent PipeAttach Pipe to the Firebox Assembly Assemble Pipe SectionsAssemble Slip Sections Slip Section Pilot HolesSecure the Vent Sections Disassemble Vent SectionsInstall Metal Roof Flashing CaulkAssemble and Install Storm Collar 13 Assembling the Storm CollarInstall RF4-8 Apply Sealant Top & Partial SidesInstall Vertical Termination Cap Heat Shield Requirements for Horizontal TerminationInstall Horizontal Termination Cap 20 Venting through the wallFuel Conversion Kit contentsGas Information Converting to LP Gas44CKP Gas Pressure Gas ConnectionOptional Accessories Requirements Wiring RequirementsStanding Pilot Ignition System Wiring Electrical InformationElectrical Service and Repair Junction Box InstallationFinishing Mantel Leg or Perpendicular WallMantel Facing MaterialFacing Template Removal Install the Refractory Appliance SetupRemove Glass Assembly Clean the ApplianceAdjust the Air Shutter Install Upper Back RefractoryAdjust the Vertical Baf e Install Logs, Ember Bed & Rockwool12 Positioning Right Front Leg Place Lava Rock and Vermiculite Install Andirons Reinstall GlassInstall Door Fronts Troubleshooting Standing Pilot Ignition SystemTroubleshooting Symptom Possible Cause Corrective ActionAppliance Dimension Diagram Reference MaterialsVent Components Diagrams DVP45BEK DVP-BEK2 DVP-TVHW DVP-TRAP Service PartsService Parts Description Serial # Part NumberOptional Components Contact Information

QFP44 specifications

The Quadra-Fire QFP44 is a highly efficient and versatile pellet stove designed to provide warmth and comfort while offering a range of advanced features and technologies. It stands out in the market for its blend of efficiency, user-friendly operation, and aesthetic appeal.

One of the key features of the QFP44 is its impressive heat output. With a heating capacity of up to 2,500 square feet, it is suitable for medium to larger living spaces, making it an ideal choice for families looking for an effective heating solution. The stove boasts an adjustable output, allowing users to set the heat level according to their specific needs, which promotes energy efficiency and enhances comfort.

The QFP44 utilizes a patented feed system that ensures a consistent and reliable supply of pellets for combustion. This technology not only maximizes fuel efficiency but also minimizes the need for frequent refueling. In addition, the stove features a large hopper capacity, capable of holding up to 45 pounds of pellets. This translates into longer burn times, enabling users to enjoy hours of warmth without constant supervision.

Another notable characteristic of the QFP44 is its advanced control system. The innovative electronic control board allows users to monitor and adjust the stove settings easily. The system includes programmable temperature settings, which enable homeowners to schedule heating times according to their lifestyle. This convenience makes the stove ideal for those who want to return to a warm home without wasting energy.

The QFP44 is also engineered with a clean-burning technology that significantly reduces emissions. This feature not only makes the stove environmentally friendly but also enhances its safety profile. The high-efficiency combustion system effectively converts pellets into heat with minimal smoke and pollutants, fulfilling strict environmental standards.

For aesthetic appeal, the QFP44 is designed with a contemporary look, featuring a large viewing window that allows users to enjoy the beautiful ambiance of the flame. The stove is available in various finishes, making it a stylish addition to any home décor.

Overall, the Quadra-Fire QFP44 combines efficiency, user-friendly technology, and an elegant design, making it a top choice for anyone seeking an effective and attractive pellet heating solution. Its blend of features ensures homeowners can enjoy both comfort and convenience during the cold months while maintaining an environmentally responsible heating option.