Quadra-Fire QFP44 owner manual Maintenance Tasks-Quali ed Service Technician

Page 20

Venting

Frequency: Seasonally

By: Homeowner

Tools needed: Protective gloves and safety glasses.

Inspect venting and termination cap for blockage or obstruction such plants, bird nests, leaves, snow, debris, etc.

Verify termination cap clearance to subsequent construction (building additions, decks, fences, or sheds). See Section 6.

Inspect for corrosion or separation.

Verify weather stripping, sealing and ashing remains intact.

Inspect draft shield to verify it is not damaged or missing.

B. Maintenance Tasks-Quali ed Service Technician

The following tasks must be performed by a quali ed service technician.

Gasket Seal and Glass Assembly Inspection

Frequency: Annually

By: Quali ed Service Technician

Tools needed: Protective gloves, drop cloth and a stable work surface.

Inspect gasket seal and its condition.

Inspect xed glass assembly for scratches and nicks that can lead to breakage when exposed to heat.

Con rm there is no damage to glass or glass frame. Replace as necessary.

• Verify that xed glass assembly is properly retained and attachment components are intact and not damaged. Replace as necessary.

Logs

Frequency: Annually

By: Quali ed Service Technician

Tools needed: Protective gloves.

Inspect for damaged or missing logs. Replace as necessary. Refer to Section 14.F. for log placement instructions.

Verify correct log placement and no ame impingement causing sooting. Correct as necessary.

Firebox

Frequency: Annually

By: Quali ed Service Technician

Tools needed: Protective gloves, sandpaper, steel wool, cloths, mineral spirits, primer and touch-up paint.

Inspect for paint condition, warped surfaces, corrosion or perforation. Sand and repaint as necessary.

Replace replace if rebox has been perforated.

Control Compartment and Firebox Top

Frequency: Annually

By: Quali ed Service Technician

Tools needed: Protective gloves, vacuum cleaner, dust cloths

Vacuum and wipe out dust, cobwebs, debris or pet hair. Use caution when cleaning these areas. Screw tips that have penetrated the sheet metal are sharp and should be avoided.

Remove all foreign objects.

Verify unobstructed air circulation.

Burner Ignition and Operation

Frequency: Annually

By: Quali ed Service Technician

Tools needed: Protective gloves, vacuum cleaner, whisk broom, ashlight, voltmeter, indexed drill bit set, and a manometer.

Verify burner is properly secured and aligned with pilot or igniter.

Clean off burner top, inspect for plugged ports, corrosion or deterioration. Replace burner if necessary.

Replace rockwool with new dime-size pieces. DO NOT block ports or obstruct lighting paths. Refer to Section 14.F. for proper rockwool placement.

Verify batteries have been removed from battery back- up IPI systems to prevent premature battery failure or leaking.

Check for smooth lighting and ignition carryover to all ports. Verify that there is no ignition delay.

Inspect for lifting or other ame problems.

Verify air shutter setting is correct. See Section 14.D. for required air shutter setting. Verify air shutter is clear of dust and debris.

• Inspect ori ce for soot, dirt and corrosion. Verify ori

ce

size is correct. See Service Parts List for proper ori

ce

sizing.

 

Verify manifold and inlet pressures. Adjust regulator as required.

Inspect pilot ame pattern and strength. See Figure 3.1 for proper pilot ame pattern. Clean or replace ori ce spud as necessary.

Inspect thermocouple/thermopile or IPI ame sensing rod for soot, corrosion and deterioration. Clean with emery cloth or replace as required.

Verify thermocouple/thermopile or IPI millivolt output. Replace as necessary.

20

Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08

Image 20
Contents What to do if you smell gas Installation and OperationModels Congratulations Homeowner Reference InformationUser Guide Table of ContentsInstaller Guide Troubleshooting CONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Your Fireplace Gas Fireplace SafetyOperating Instructions Fixed Glass Assembly Clear SpaceDecorative Doors and Fronts Dashboard ControlCanadian Equipment Requirements Ignitor Battery BoxRemote Operation Remote Receiver TransmitterTransmitter Settings Setting the ClockMatching Security Codes Operating InstructionsSetting F/C Scale Setting Desired Room Temperature Ther- mo OperationsSetting the Countdown Timer Operating the Fan Operates in on or THER- MO modeAdjusting the Flame Height Operates in on or Thermo mode Low/Battery IndicatorTransmitter Safety Features Thermo-Updating and Communication-Safety FeaturesTimer Operation Battery LifeBefore Lighting Fireplace General Information Transmitter Wall BracketFor Your Safety Read Before Lighting Lighting Instructions SPAfter Fireplace is Lit Frequently Asked QuestionsInitial Break-in Procedure Maintenance and Service Maintenance Tasks-HomeownerGlass Cleaning Remote ControlMaintenance Tasks-Quali ed Service Technician Standing Pilot Flame Patterns Getting Started Typical Appliance SystemInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Framing and Clearances Select Appliance LocationConstruct the Appliance Chase ClearancesMantel Legs or Wall Projections Mantel and Wall ProjectionsMantels Termination Locations Vent Termination Minimum ClearancesMinimum Clearances for Termination Vent Information and Diagrams Approved PipeVent Table Key Use of ElbowsOne Elbow Vent DiagramsTop Vent Horizontal Termination Two 45 Elbows replacing One 90 Elbow Three ElbowsTwo Elbows Top Vent Vertical TerminationNo Elbow 12 ft 3.66 m min 60 ft 18.29 m max Vent Clearances and Framing Pipe Clearances to CombustiblesWall Penetration Framing Combustible Wall PenetrationInstall the Ceiling Firestop Installing Ceiling FirestopVaulted Ceiling Installation Install Attic Insulation ShieldFlat Ceiling Installation Appliance Preparation Secure and Level the ApplianceInstall Vent Pipe Attach Pipe to the Firebox AssemblyAssemble Vent Sections Assemble Pipe SectionsAssemble Slip Sections Slip Section Pilot HolesSecure the Vent Sections Disassemble Vent SectionsInstall Metal Roof Flashing CaulkAssemble and Install Storm Collar 13 Assembling the Storm CollarInstall RF4-8 Apply Sealant Top & Partial SidesInstall Vertical Termination Cap Heat Shield Requirements for Horizontal TerminationInstall Horizontal Termination Cap 20 Venting through the wallKit contents Gas InformationFuel Conversion Converting to LP Gas44CKP Gas Pressure Gas ConnectionWiring Requirements Standing Pilot Ignition System WiringOptional Accessories Requirements Electrical InformationElectrical Service and Repair Junction Box InstallationFinishing Mantel Leg or Perpendicular WallMantel Facing MaterialFacing Template Removal Appliance Setup Remove Glass AssemblyInstall the Refractory Clean the ApplianceAdjust the Air Shutter Install Upper Back RefractoryAdjust the Vertical Baf e Install Logs, Ember Bed & Rockwool12 Positioning Right Front Leg Place Lava Rock and Vermiculite Install Andirons Reinstall GlassInstall Door Fronts Troubleshooting Standing Pilot Ignition SystemTroubleshooting Symptom Possible Cause Corrective ActionAppliance Dimension Diagram Reference MaterialsVent Components Diagrams DVP45BEK DVP-BEK2 DVP-TVHW DVP-TRAP Service PartsService Parts Description Serial # Part NumberOptional Components Contact Information

QFP44 specifications

The Quadra-Fire QFP44 is a highly efficient and versatile pellet stove designed to provide warmth and comfort while offering a range of advanced features and technologies. It stands out in the market for its blend of efficiency, user-friendly operation, and aesthetic appeal.

One of the key features of the QFP44 is its impressive heat output. With a heating capacity of up to 2,500 square feet, it is suitable for medium to larger living spaces, making it an ideal choice for families looking for an effective heating solution. The stove boasts an adjustable output, allowing users to set the heat level according to their specific needs, which promotes energy efficiency and enhances comfort.

The QFP44 utilizes a patented feed system that ensures a consistent and reliable supply of pellets for combustion. This technology not only maximizes fuel efficiency but also minimizes the need for frequent refueling. In addition, the stove features a large hopper capacity, capable of holding up to 45 pounds of pellets. This translates into longer burn times, enabling users to enjoy hours of warmth without constant supervision.

Another notable characteristic of the QFP44 is its advanced control system. The innovative electronic control board allows users to monitor and adjust the stove settings easily. The system includes programmable temperature settings, which enable homeowners to schedule heating times according to their lifestyle. This convenience makes the stove ideal for those who want to return to a warm home without wasting energy.

The QFP44 is also engineered with a clean-burning technology that significantly reduces emissions. This feature not only makes the stove environmentally friendly but also enhances its safety profile. The high-efficiency combustion system effectively converts pellets into heat with minimal smoke and pollutants, fulfilling strict environmental standards.

For aesthetic appeal, the QFP44 is designed with a contemporary look, featuring a large viewing window that allows users to enjoy the beautiful ambiance of the flame. The stove is available in various finishes, making it a stylish addition to any home décor.

Overall, the Quadra-Fire QFP44 combines efficiency, user-friendly technology, and an elegant design, making it a top choice for anyone seeking an effective and attractive pellet heating solution. Its blend of features ensures homeowners can enjoy both comfort and convenience during the cold months while maintaining an environmentally responsible heating option.