B. Design and Installation Considerations

Quadra-Fire direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the out- side. No additional outside air source is required.

Installation MUST comply with local, regional, state and national codes and regulations. Consult insurance carrier, local building inspector, re of cials or authorities having jurisdiction over restrictions, installation inspection and permits.

Before installing, determine the following:

Where the appliance is to be installed.

The vent system con guration to be used.

Gas supply piping.

Electrical wiring requirements.

Framing and nishing details.

Whether optional accessories—devices such as a fan, wall switch, or remote control—are desired.

Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. For assistance or additional information, consult a quali ed service technician, service agency or your dealer.

C. Tools and Supplies Needed

Before beginning the installation be sure that the following tools and building supplies are available.

Tape measure

Framing material

Pliers

High temperature caulking

material

 

Hammer

Phillips screwdriver

Gloves

Framing square

Voltmeter

Electric drill and bits (1/4 in.)

Plumb line

Safety glasses

Level

Reciprocating saw

Manometer

Flat blade screwdriver

Non-corrosive leak check solution

1/2 - 3/4 in. length, #6 or #8 Self-drilling screws

One 1/4 in. female connection (for optional fan).

WARNING! Risk of Fire, Explosion or Electric Shock! DO NOT use this appliance if any part has been under wa- ter. Call a quali ed service technician to inspect the appli- ance and to replace any part of the control system and/or gas control which has been under water.

D. Inspect Appliance and Components

Carefully remove the appliance and components from the packaging (refer to Figure 4.2).

-Remove refractory from back of unit by removing the screws from shipping bracket.

-Remove screws from shipping brackets before trying to remove unit from pallet.

-Remove and save screws from andirons for later installation.

-Remove screw from top of each carrying handle. Handles have been provided to assist in moving the unit.

The vent system components and decorative doors and fronts are shipped in separate packages.

Report to your dealer any parts damaged in shipment, particularly the condition of the glass.

Read all of the instructions before starting the installation. Follow these instructions carefully during the installation to ensure maximum safety and bene t.

WARNING! Risk of Fire or Explosion! Damaged parts could impair safe operation. DO NOT install damaged, incomplete or substitute components. Keep appliance dry.

Refractory

Andirons

Shipping Brackets

Figure 4.2 Refractory Shipping Location, Brackets

Hearth & Home Technologies disclaims any responsibility for, and the warranty will be voided by, the following actions:

Installation and use of any damaged appliance or vent system component.

Modi cation of the appliance or vent system.

Installation other than as instructed by Hearth & Home Technologies.

Improper positioning of the gas logs or the glass door.

Installation and/or use of any component part not approved by Hearth & Home Technologies.

Any such action may cause a re hazard.

Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08

23

Image 23
Contents What to do if you smell gas Installation and OperationModels Homeowner Reference Information CongratulationsUser Guide Table of ContentsInstaller Guide Troubleshooting CONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Your Fireplace Gas Fireplace SafetyOperating Instructions Dashboard Control Fixed Glass AssemblyClear Space Decorative Doors and FrontsCanadian Equipment Requirements Ignitor Battery BoxRemote Operation Transmitter Remote ReceiverOperating Instructions Transmitter SettingsSetting the Clock Matching Security CodesOperating the Fan Operates in on or THER- MO mode Setting F/C ScaleSetting Desired Room Temperature Ther- mo Operations Setting the Countdown TimerThermo-Updating and Communication-Safety Features Adjusting the Flame Height Operates in on or Thermo modeLow/Battery Indicator Transmitter Safety FeaturesGeneral Information Transmitter Wall Bracket Timer OperationBattery Life Before Lighting FireplaceLighting Instructions SP For Your Safety Read Before LightingAfter Fireplace is Lit Frequently Asked QuestionsInitial Break-in Procedure Remote Control Maintenance and ServiceMaintenance Tasks-Homeowner Glass CleaningMaintenance Tasks-Quali ed Service Technician Standing Pilot Flame Patterns Typical Appliance System Getting StartedInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Select Appliance Location Framing and ClearancesClearances Construct the Appliance ChaseMantel Legs or Wall Projections Mantel and Wall ProjectionsMantels Vent Termination Minimum Clearances Termination LocationsMinimum Clearances for Termination Use of Elbows Vent Information and DiagramsApproved Pipe Vent Table KeyOne Elbow Vent DiagramsTop Vent Horizontal Termination Three Elbows Two 45 Elbows replacing One 90 ElbowTwo Elbows Top Vent Vertical TerminationNo Elbow 12 ft 3.66 m min 60 ft 18.29 m max Combustible Wall Penetration Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration FramingInstalling Ceiling Firestop Install the Ceiling FirestopVaulted Ceiling Installation Install Attic Insulation ShieldFlat Ceiling Installation Secure and Level the Appliance Appliance PreparationAssemble Pipe Sections Install Vent PipeAttach Pipe to the Firebox Assembly Assemble Vent SectionsSlip Section Pilot Holes Assemble Slip SectionsDisassemble Vent Sections Secure the Vent SectionsCaulk Install Metal Roof Flashing13 Assembling the Storm Collar Assemble and Install Storm CollarApply Sealant Top & Partial Sides Install RF4-8Heat Shield Requirements for Horizontal Termination Install Vertical Termination Cap20 Venting through the wall Install Horizontal Termination CapConverting to LP Gas Kit contentsGas Information Fuel Conversion44CKP Gas Connection Gas PressureElectrical Information Wiring RequirementsStanding Pilot Ignition System Wiring Optional Accessories RequirementsJunction Box Installation Electrical Service and RepairMantel Leg or Perpendicular Wall FinishingMantel Facing MaterialFacing Template Removal Clean the Appliance Appliance SetupRemove Glass Assembly Install the RefractoryInstall Upper Back Refractory Adjust the Air ShutterInstall Logs, Ember Bed & Rockwool Adjust the Vertical Baf e12 Positioning Right Front Leg Place Lava Rock and Vermiculite Install Andirons Reinstall GlassInstall Door Fronts Standing Pilot Ignition System TroubleshootingSymptom Possible Cause Corrective Action TroubleshootingReference Materials Appliance Dimension DiagramDVP45 Vent Components DiagramsBEK DVP-BEK2 DVP-TVHW DVP-TRAP Parts ServiceDescription Serial # Part Number Service PartsOptional Components Contact Information

QFP44 specifications

The Quadra-Fire QFP44 is a highly efficient and versatile pellet stove designed to provide warmth and comfort while offering a range of advanced features and technologies. It stands out in the market for its blend of efficiency, user-friendly operation, and aesthetic appeal.

One of the key features of the QFP44 is its impressive heat output. With a heating capacity of up to 2,500 square feet, it is suitable for medium to larger living spaces, making it an ideal choice for families looking for an effective heating solution. The stove boasts an adjustable output, allowing users to set the heat level according to their specific needs, which promotes energy efficiency and enhances comfort.

The QFP44 utilizes a patented feed system that ensures a consistent and reliable supply of pellets for combustion. This technology not only maximizes fuel efficiency but also minimizes the need for frequent refueling. In addition, the stove features a large hopper capacity, capable of holding up to 45 pounds of pellets. This translates into longer burn times, enabling users to enjoy hours of warmth without constant supervision.

Another notable characteristic of the QFP44 is its advanced control system. The innovative electronic control board allows users to monitor and adjust the stove settings easily. The system includes programmable temperature settings, which enable homeowners to schedule heating times according to their lifestyle. This convenience makes the stove ideal for those who want to return to a warm home without wasting energy.

The QFP44 is also engineered with a clean-burning technology that significantly reduces emissions. This feature not only makes the stove environmentally friendly but also enhances its safety profile. The high-efficiency combustion system effectively converts pellets into heat with minimal smoke and pollutants, fulfilling strict environmental standards.

For aesthetic appeal, the QFP44 is designed with a contemporary look, featuring a large viewing window that allows users to enjoy the beautiful ambiance of the flame. The stove is available in various finishes, making it a stylish addition to any home décor.

Overall, the Quadra-Fire QFP44 combines efficiency, user-friendly technology, and an elegant design, making it a top choice for anyone seeking an effective and attractive pellet heating solution. Its blend of features ensures homeowners can enjoy both comfort and convenience during the cold months while maintaining an environmentally responsible heating option.