Quadra-Fire QFP44 owner manual Troubleshooting, Symptom Possible Cause Corrective Action

Page 59

Troubleshooting (continued)

Symptom

Possible Cause

Corrective Action

3. (Continued)

C. Failed valve.

Turn the valve knob to the ON position. Place the ON/OFF switch

 

 

in the ON position. Check the millivolt meter a the thermopile

 

 

terminals. The millivolt meter should read greater than 125mV. If the

 

 

reading is acceptable, and if the burner does not come on, replace

 

 

the gas valve.

 

 

 

 

D. Plugged burner ori ce.

Check the burner ori ce for stoppage. Remove stoppage.

 

 

 

 

E. Wall switch or wires.

Check the wall switch and wires for proper connections. Place the

 

 

jumper wires across the terminals at the wall switch. If the burner

 

 

comes on, replace the wall switch. If the wall switch is OK, place

 

 

the jumper wires across the wall switch wires at the gas valve. If the

 

 

burner comes on, the wires are faulty or connections are bad.

 

 

 

4. Frequent pilot outage

A. Pilot ame may be too high or

Clean thermocouple and adjust the pilot ame for proper ame

problem.

too low, or blowing out (high

impingement. Follow lighting instructions carefully.

 

pressure), causing pilot safety

 

 

to drop out.

 

5. The pilot and main

A. No LP in tank.

Check the LP (propane) tank. Re ll the fuel tank.

burner extinguish while in

 

 

B. Improper gas inlet pressure.

Verify with manometer. NG should read 5-14 inches w.c. LP should

operation.

 

read 10-14 inches w.c.

 

 

 

C. Inner vent pipe leaking exhaust

Check venting system for damage. Replace/repair improperly

 

gases back into the system.

assembled pipe sections.

 

 

 

 

D. Glass installed improperly.

Check to ensure glass is installed properly. Replace glass panel

 

 

assembly.

 

E. Failed thermopile or

Replace pilot if necessary.

 

thermocouple.

 

 

F. Improper vent cap installation.

Check for proper installation and freedom from debris or blockage.

 

 

 

6. Glass soots.

A. Flame impingement.

Adjust the log set so that the ame does not excessively impinge on

 

 

it. Refer to log instructions.

 

B. Improper air shutter setting.

Refer to manual for shutter set points. Ensure that set point is

 

 

correct for appliance/gas type. If unit has adjustable shutter, it may

 

 

be necessary to increase shutter opening.

 

C. Debris around air shutter.

Inspect the opening at the base of the burner. NO MATERIAL

 

 

SHOULD BE PLACED IN THIS OPENING.

7. Flame burns blue and lifts

A. Insuf cient oxygen being

Ensure that the vent cap is installed properly and free of debris.

off burner.

supplied.

Ensure that the vent system joints are tight and have no leaks.

 

 

Ensure that no debris has been placed at the base of, or in the area

 

 

of the air holes in the center of the base pan beneath the burner.

 

 

 

 

 

Ensure that the glass is tightened properly on the unit, particularly

 

 

on top corners.

Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08

59

Image 59
Contents What to do if you smell gas Installation and OperationModels Homeowner Reference Information CongratulationsUser Guide Table of ContentsInstaller Guide Troubleshooting CONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Your Fireplace Gas Fireplace SafetyOperating Instructions Dashboard Control Fixed Glass AssemblyClear Space Decorative Doors and FrontsCanadian Equipment Requirements Ignitor Battery BoxRemote Operation Transmitter Remote ReceiverOperating Instructions Transmitter SettingsSetting the Clock Matching Security CodesOperating the Fan Operates in on or THER- MO mode Setting F/C ScaleSetting Desired Room Temperature Ther- mo Operations Setting the Countdown TimerThermo-Updating and Communication-Safety Features Adjusting the Flame Height Operates in on or Thermo modeLow/Battery Indicator Transmitter Safety FeaturesGeneral Information Transmitter Wall Bracket Timer OperationBattery Life Before Lighting FireplaceLighting Instructions SP For Your Safety Read Before LightingAfter Fireplace is Lit Frequently Asked QuestionsInitial Break-in Procedure Remote Control Maintenance and ServiceMaintenance Tasks-Homeowner Glass CleaningMaintenance Tasks-Quali ed Service Technician Standing Pilot Flame Patterns Typical Appliance System Getting StartedInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Select Appliance Location Framing and ClearancesClearances Construct the Appliance ChaseMantel Legs or Wall Projections Mantel and Wall ProjectionsMantels Vent Termination Minimum Clearances Termination LocationsMinimum Clearances for Termination Use of Elbows Vent Information and DiagramsApproved Pipe Vent Table KeyOne Elbow Vent DiagramsTop Vent Horizontal Termination Three Elbows Two 45 Elbows replacing One 90 ElbowTwo Elbows Top Vent Vertical TerminationNo Elbow 12 ft 3.66 m min 60 ft 18.29 m max Combustible Wall Penetration Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration FramingInstalling Ceiling Firestop Install the Ceiling FirestopVaulted Ceiling Installation Install Attic Insulation ShieldFlat Ceiling Installation Secure and Level the Appliance Appliance PreparationAssemble Pipe Sections Install Vent PipeAttach Pipe to the Firebox Assembly Assemble Vent SectionsSlip Section Pilot Holes Assemble Slip SectionsDisassemble Vent Sections Secure the Vent SectionsCaulk Install Metal Roof Flashing13 Assembling the Storm Collar Assemble and Install Storm CollarApply Sealant Top & Partial Sides Install RF4-8Heat Shield Requirements for Horizontal Termination Install Vertical Termination Cap20 Venting through the wall Install Horizontal Termination CapConverting to LP Gas Kit contentsGas Information Fuel Conversion44CKP Gas Connection Gas PressureElectrical Information Wiring RequirementsStanding Pilot Ignition System Wiring Optional Accessories RequirementsJunction Box Installation Electrical Service and RepairMantel Leg or Perpendicular Wall FinishingMantel Facing MaterialFacing Template Removal Clean the Appliance Appliance SetupRemove Glass Assembly Install the RefractoryInstall Upper Back Refractory Adjust the Air ShutterInstall Logs, Ember Bed & Rockwool Adjust the Vertical Baf e12 Positioning Right Front Leg Place Lava Rock and Vermiculite Install Andirons Reinstall GlassInstall Door Fronts Standing Pilot Ignition System TroubleshootingSymptom Possible Cause Corrective Action TroubleshootingReference Materials Appliance Dimension DiagramDVP45 Vent Components DiagramsBEK DVP-BEK2 DVP-TVHW DVP-TRAP Parts ServiceDescription Serial # Part Number Service PartsOptional Components Contact Information

QFP44 specifications

The Quadra-Fire QFP44 is a highly efficient and versatile pellet stove designed to provide warmth and comfort while offering a range of advanced features and technologies. It stands out in the market for its blend of efficiency, user-friendly operation, and aesthetic appeal.

One of the key features of the QFP44 is its impressive heat output. With a heating capacity of up to 2,500 square feet, it is suitable for medium to larger living spaces, making it an ideal choice for families looking for an effective heating solution. The stove boasts an adjustable output, allowing users to set the heat level according to their specific needs, which promotes energy efficiency and enhances comfort.

The QFP44 utilizes a patented feed system that ensures a consistent and reliable supply of pellets for combustion. This technology not only maximizes fuel efficiency but also minimizes the need for frequent refueling. In addition, the stove features a large hopper capacity, capable of holding up to 45 pounds of pellets. This translates into longer burn times, enabling users to enjoy hours of warmth without constant supervision.

Another notable characteristic of the QFP44 is its advanced control system. The innovative electronic control board allows users to monitor and adjust the stove settings easily. The system includes programmable temperature settings, which enable homeowners to schedule heating times according to their lifestyle. This convenience makes the stove ideal for those who want to return to a warm home without wasting energy.

The QFP44 is also engineered with a clean-burning technology that significantly reduces emissions. This feature not only makes the stove environmentally friendly but also enhances its safety profile. The high-efficiency combustion system effectively converts pellets into heat with minimal smoke and pollutants, fulfilling strict environmental standards.

For aesthetic appeal, the QFP44 is designed with a contemporary look, featuring a large viewing window that allows users to enjoy the beautiful ambiance of the flame. The stove is available in various finishes, making it a stylish addition to any home décor.

Overall, the Quadra-Fire QFP44 combines efficiency, user-friendly technology, and an elegant design, making it a top choice for anyone seeking an effective and attractive pellet heating solution. Its blend of features ensures homeowners can enjoy both comfort and convenience during the cold months while maintaining an environmentally responsible heating option.