Quadra-Fire QV-PIER, QV-ST owner manual 2Getting Started, Introducing the Quadra-FireGas Fireplaces

Page 10
2Getting Started

2Getting Started

Introducing the Quadra-Fire Gas Fireplaces

Quadra-Fire direct vent gas fireplaces are designed to op- erate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside.

The information contained in this Installers Guide, unless noted otherwise, applies to all models and gas control systems. Gas fireplace diagrams, including the dimensions, are shown in this section.

Pre-install Preparation

This gas fireplace and its components are tested and safe when installed in accordance with this Installers Guide. Report to your dealer any parts damaged in shipment, particularly the condition of the glass. Do not install any unit with damaged, incomplete, or substitute parts.

The vent system components are shipped in separate pack- ages. The gas logs are packaged separately and must be field installed.

Read all of the instructions before starting the instal- lation. Follow these instructions carefully during the installation to ensure maximum safety and benefit. Failure to follow these instructions will void the own- er’s warranty and may present a fire hazard.

The Quadra-Fire Warranty will be voided by, and Quadra- Fire disclaims any responsibility for, the following actions:

Installation of any damaged fireplace or vent system component.

Modification of the fireplace or direct vent system.

Installation other than as instructed by Quadra-Fire.

Improper positioning of the gas logs or the glass door.

Installation and/or use of any component part not manu- factured and approved by Quadra-Fire, not withstanding any independent testing laboratory or other party approval of such component part or accessory.

ANY SUCH ACTION MAY POSSIBLY CAUSE A FIRE HAZARD.

When planning a fireplace installation, it’s necessary to determine:

Where the unit is to be installed.

The vent system configuration to be used.

Gas supply piping.

Electrical wiring.

Framing and finishing details.

Whether optional accessories—devices such as a fan, wall switch, or remote control—are desired.

If the fireplace is to be installed on carpeting or tile, or on any combustible material other than wood flooring, the fireplace should be installed on a metal or wood panel that extends the full width and depth of the fireplace.

10

Quadra-FireQV-PIER, QV-ST Series: HV-IPI2005-901 Rev. G • 2/06

Image 10
Contents Models QV-Pier QV-ST Series HV-IPI What to do if you smell gasSafety and Warning Information PROHIBITEDTable of Contents QV-Pier-HV-IPI Service Parts List6 Log Assembly COMMON PART ACCESSORIESQV-PIER-HV-IPI SERIAL #QV-ST-HV-IPI Service Parts11710 NG, LP Exploded Parts DiagramQV-ST-HV-IPI QV-PIER-HV-IPI Service PartsQV-ST-HV-IPI High Altitude Installations 1Approvals and CodesInstallation Codes Appliance CertificationPre-installPreparation 2Getting StartedIntroducing the Quadra-FireGas Fireplaces Diagram of the QV-PIER-HV-IPI TOP STANDOFFS GAS LINE ACCESSELECTRICAL ACCESS REAR VENT3Installing the Fireplace Step 1. Locating the FireplaceStep 2. Framing the Fireplace 35-3/4 ModelQV-PIER-HV-IPI QV-ST-HV-IPINOTE PIPES OVERLAP 1-1/4INCHES AT EACH JOINT DVP90STTEMS OR COMPONENTS MAY BE USED Step 3. Installing the Vent SystemA. Vent System Approvals Identifying Vent ComponentsFlue Restrictor Instructions Figure 13. Venting with One 90 Elbow Figure 14. Venting with One 90 ElbowFigure 15. Venting with Two 90 Elbows Venting with Two 90 Elbows Figure 17. Venting with Two 90 ElbowsFigure 18. Venting with three 90 elbows Figure 19. Venting with three 90 elbows B. Installing Vent Components Venting Out Vertically2. Continue Adding Vent Components Figure 25 Hole & New Framing Members = VENT TERMINAL = AREA WHERE TERMINAL IS NOT PERMITTEDFigure 29. Vent Termination Minimum Clearances X = AIR SUPPLY INLETMark the roof hole accordingly Step 5. The Gas Control System Propane PressureNatural Gas 5.0 inchesOperation using Battery Power Step 8. Wiring the FireplaceFor Intermittent Pilot Ignition Wiring Appliance RequirementsFan Installation Figure 35. Fan Wiring DiagramOptional Accessories Wall SwitchIN ANY MANNER Step 9. FinishingFigure 40. Sealant Material Hearth Extensions ANDIRONS 1/2”ANDIRON TABS Page Figure 53. Placement of the Ember Material Placing the Ember MaterialStep 11. Before Lighting the Fireplace After the InstallationStep 12. Lighting the Fireplace 4Maintaining and Servicing Your Fireplace Fireplace MaintenancePossible Causes 5 TroubleshootingSymptom Corrective ActionsPossible Causes SymptomIntellifire Ignition System - continued Corrective ActionsTHREE YEAR WARRANTY Lifetime WarrantyLIMITED LIFETIME WARRANTY TWO YEAR WARRANTY