Quadra-Fire QV-PIER, QV-ST owner manual NOTE PIPES OVERLAP 1-1/4INCHES AT EACH JOINT, DVP90ST

Page 16
DVP90ST

4

6

12

DVP4

DVP6

DVP12

 

14-1/4

12-3/16

2

MAX.

MIN.

 

 

24

DVP12A

36

48

9-7/8

DVP24

 

 

45.0O

10-1/4

DVP45

DVP36

11-1/4

7-1/4

1-1/4 TYP

DVP48

8-9/16

1/2 TYP

12-9/16

DVP90ST

NOTE: PIPES OVERLAP 1-1/4 INCHES

AT EACH JOINT.

Figure 6. DVP-Series Direct Vent Component Specifications (5-inch inner pipe / 8-inch outer pipe)

16

Quadra-FireQV-PIER, QV-ST Series: HV-IPI2005-901 Rev. G • 2/06

Image 16
Contents Models QV-Pier QV-ST Series HV-IPI What to do if you smell gasSafety and Warning Information PROHIBITEDTable of Contents QV-Pier-HV-IPI Service Parts List6 Log Assembly ACCESSORIES QV-PIER-HV-IPICOMMON PART SERIAL #Service Parts 11710QV-ST-HV-IPI NG, LP Exploded Parts DiagramQV-ST-HV-IPI QV-PIER-HV-IPI Service PartsQV-ST-HV-IPI 1Approvals and Codes Installation CodesHigh Altitude Installations Appliance CertificationPre-installPreparation 2Getting StartedIntroducing the Quadra-FireGas Fireplaces Diagram of the QV-PIER-HV-IPI GAS LINE ACCESS ELECTRICAL ACCESSTOP STANDOFFS REAR VENT3Installing the Fireplace Step 1. Locating the FireplaceStep 2. Framing the Fireplace Model QV-PIER-HV-IPI35-3/4 QV-ST-HV-IPINOTE PIPES OVERLAP 1-1/4INCHES AT EACH JOINT DVP90STStep 3. Installing the Vent System A. Vent System ApprovalsTEMS OR COMPONENTS MAY BE USED Identifying Vent ComponentsFlue Restrictor Instructions Figure 13. Venting with One 90 Elbow Figure 14. Venting with One 90 ElbowFigure 15. Venting with Two 90 Elbows Venting with Two 90 Elbows Figure 17. Venting with Two 90 ElbowsFigure 18. Venting with three 90 elbows Figure 19. Venting with three 90 elbows B. Installing Vent Components Venting Out Vertically2. Continue Adding Vent Components Figure 25 Hole & New Framing Members = AREA WHERE TERMINAL IS NOT PERMITTED Figure 29. Vent Termination Minimum Clearances= VENT TERMINAL X = AIR SUPPLY INLETMark the roof hole accordingly Step 5. The Gas Control System Pressure Natural GasPropane 5.0 inchesStep 8. Wiring the Fireplace For Intermittent Pilot Ignition WiringOperation using Battery Power Appliance RequirementsFigure 35. Fan Wiring Diagram Optional AccessoriesFan Installation Wall SwitchIN ANY MANNER Step 9. FinishingFigure 40. Sealant Material Hearth Extensions ANDIRONS 1/2”ANDIRON TABS Page Figure 53. Placement of the Ember Material Placing the Ember MaterialStep 11. Before Lighting the Fireplace After the InstallationStep 12. Lighting the Fireplace 4Maintaining and Servicing Your Fireplace Fireplace Maintenance5 Troubleshooting SymptomPossible Causes Corrective ActionsSymptom Intellifire Ignition System - continuedPossible Causes Corrective ActionsLifetime Warranty LIMITED LIFETIME WARRANTYTHREE YEAR WARRANTY TWO YEAR WARRANTY