Quadra-Fire QV-PIER, QV-ST Intellifire Ignition System - continued, Symptom, Possible Causes

Page 40

Intellifire Ignition System - (continued)

Symptom

Possible Causes

Corrective Actions

 

c. Module is not

Verify that module is securely grounded to metal chassis of appliance. Verify

 

grounded.

that wire harness is firmly connected to module.

 

d. Damaged pilot

Verify that ceramic insulator around the sensor rod is not cracked, damaged,

 

assembly or dirty

or loose. Verify connection from sensor rod to white sensor wire. Clean

 

sensor rod.

sensor rod with emery cloth to remove any contaminants that may have

 

 

accumulated on sensor rod. Verify continuity with a multimeter with ohms set

 

 

at lowest range.

 

e. Faulty module.

Turn ON/OFF rocker switch or wall switch to OFF position. Remove ignitor

 

 

wire "I" from module. Place ON/OFF Rocker switch or wall switch in ON

 

 

position. Hold ground wire about 3/16 inch away from "I" terminal on module.

 

 

If there is no spark at "I" terminal module must be replaced. If there is a

 

 

spark at "I" terminal, module is fine. Inspect pilot assembly for shorted

 

 

sparker wire or cracked insulator around electrode.

4. Pilot sparks, but

a. Correct gas

Verify that incoming gas line ball valve is "open". Verify that inlet pressure

Pilot will not light.

supply.

reading is within acceptable limits, inlet pressure must not exceed 14 in.

 

 

W.C.

 

b. Ignitor gap is

Verify that spark gap from ignitor to pilot hood is .17 in. or 1/8 in.

 

too large.

 

 

c. Module is not

Verify module is securely grounded to metal chassis of appliance.

 

grounded.

 

 

 

 

40

Quadra-FireQV-PIER, QV-ST Series: HV-IPI2005-901 Rev. G • 2/06

Image 40
Contents Models QV-Pier QV-ST Series HV-IPI What to do if you smell gasSafety and Warning Information PROHIBITEDTable of Contents QV-Pier-HV-IPI Service Parts List6 Log Assembly ACCESSORIES QV-PIER-HV-IPICOMMON PART SERIAL #Service Parts 11710QV-ST-HV-IPI NG, LP Exploded Parts DiagramQV-ST-HV-IPI QV-PIER-HV-IPI Service PartsQV-ST-HV-IPI 1Approvals and Codes Installation CodesHigh Altitude Installations Appliance CertificationPre-installPreparation 2Getting StartedIntroducing the Quadra-FireGas Fireplaces Diagram of the QV-PIER-HV-IPI GAS LINE ACCESS ELECTRICAL ACCESSTOP STANDOFFS REAR VENT3Installing the Fireplace Step 1. Locating the FireplaceStep 2. Framing the Fireplace Model QV-PIER-HV-IPI35-3/4 QV-ST-HV-IPINOTE PIPES OVERLAP 1-1/4INCHES AT EACH JOINT DVP90STStep 3. Installing the Vent System A. Vent System ApprovalsTEMS OR COMPONENTS MAY BE USED Identifying Vent ComponentsFlue Restrictor Instructions Figure 13. Venting with One 90 Elbow Figure 14. Venting with One 90 ElbowFigure 15. Venting with Two 90 Elbows Venting with Two 90 Elbows Figure 17. Venting with Two 90 ElbowsFigure 18. Venting with three 90 elbows Figure 19. Venting with three 90 elbows B. Installing Vent Components Venting Out Vertically2. Continue Adding Vent Components Figure 25 Hole & New Framing Members = AREA WHERE TERMINAL IS NOT PERMITTED Figure 29. Vent Termination Minimum Clearances= VENT TERMINAL X = AIR SUPPLY INLETMark the roof hole accordingly Step 5. The Gas Control System Pressure Natural GasPropane 5.0 inchesStep 8. Wiring the Fireplace For Intermittent Pilot Ignition WiringOperation using Battery Power Appliance RequirementsFigure 35. Fan Wiring Diagram Optional AccessoriesFan Installation Wall SwitchIN ANY MANNER Step 9. FinishingFigure 40. Sealant Material Hearth Extensions ANDIRONS 1/2”ANDIRON TABS Page Figure 53. Placement of the Ember Material Placing the Ember MaterialStep 11. Before Lighting the Fireplace After the InstallationStep 12. Lighting the Fireplace 4Maintaining and Servicing Your Fireplace Fireplace Maintenance5 Troubleshooting SymptomPossible Causes Corrective ActionsSymptom Intellifire Ignition System - continuedPossible Causes Corrective ActionsLifetime Warranty LIMITED LIFETIME WARRANTYTHREE YEAR WARRANTY TWO YEAR WARRANTY