TEMPERATURE SENSOR SWITCH
NOTE: If any of the original wire as supplied with the appliance must be replaced, it must be replaced with the type 105oC rated wire.
FAN JUNCTION
BOX
SPEED CONTROL
(RHEOSTAT)
SEE DETAIL A
Figure 35. Fan Wiring Diagram
DETAIL A SCALE 1/1
Optional Accessories
Optional fan and remote control kits require that
Fan Installation
Recommended fan locations for the type of fireplace you have (see Figures 36 and 37).
Wall Switch
Position the wall switch in the desired position on a wall. Run a maximum of 25 feet (7.8 m) or less length of 18 A.W.G. minimum wire and connect it to the fireplace ON/OFF switch pigtails.
CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC- TION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPERAND DANGEROUS OPERATION. VERIFY PROPER OPERATION AFTER SERVICING.
FAN |
Figure 36. Corner fan location |
Corner fan location
It is recommended to position the fan in this location as shown. This will provide the best air flow (see Figure 36).
FAN |
Figure 37. ST & PIER fan location |
ST & Pier fan location
It is recommended to position the fan on the same side of the fireplace as the vent collars are on. This will provide the best air flow (see Figure 37).