Mr. Heater HS25NG/LP, MH25NG/LP owner manual Typical Piping Installation

Page 9

quirements and piping requirements are fulfilled, install piping as follows:

A.In accordance with the above piping requirements, assemble piping, sediment trap, shutoff valve, and necessary fittings. Tighten all components securely.

WARNING: Failure to ensure that male threads on pipe to be installed into gas valve meet the require- ments of Figure 6 may cause gas valve damage, distortion and malfunction.

B.Install a threaded nipple, prepared in accordance with paragraph 3.2 into gas valve.

C.Connect gas piping to nipple installed in the gas valve.

WARNING: When testing gas piping use only a soap and water solution. Do not use a match or other flame for leak testing. If during leakage check gas is smelled, turn off the gas supply and ventilate building.

D.Ensure the building is properly ventilated. Without lighting the pilot light of the heater, open the gas supply valve and pressurize the piping up to the heater’s gas valve.

E.Using a brush, apply a soap and water solution to all connections and look for bubbles indicating a leak. If a leak is detected, turn off gas supply and tighten connections. Retest and tighten connections

SUPPLY

LINE

SHUTOFF

VALVE

1/2”

TEE

3”

NIPPLE

CAP

RIGID PIPE WITH

UNION OR A FLEXIBLE CON- NECTOR TO HEATER

HEATER

NOTE:

1.ONLY USE A PIPE COMPOUND WHICH IS RESISTANT TO LIQUIFIED GASES ON LP INSTALLATIONS.

2.FITTINGS SHOWN ARE NOT INCLUDED WITH HEATER.

Figure 7. Typical Piping Installation

Model # MH25NG/LP

HS25NG/LP

E9

Installation instructions and Owner’s Manual

Image 9
Contents English GAS Fired INFRA-RED Workshop HeaterSpanish FrenchTable of Contents Chapter Introduction EquipmentPurpose of Equipment See Tables 1 and 2 for heater specifications Heater Dimensions and Orifice SizesGeneral Information BTU Ratings and Supply PressuresGeneral Installation Information and Requirements Chapter Heater InstallationOnly Flue Side of Heater can Heater Side Reflector MustHeater Mounting Instructions Heater Mounting Information Piping Installation Connecting Heater to GAS SupplyGas Supply Requirements Piping RequirementsTypical Piping Installation Flame for Leak Testing Operating Safety Instructions Heater StartupChapter Heater Operating Instructions PressureLighting of Pilot Burner Heater ShutdownTroubleshooting Chapter Operator Maintenance InstructionsAdjusting the Pilot Flame ER Unit Beneath Cover ScrewSymptoms Causes Solutions Replacing the GAS Valve UnitFrequency of Operator Checks Please do not Return this Appliance to Your Store If Service is RequiredALL Warranty Claims Require Proof of Purchase Chapter Replacement Parts ListFor Additional Information For Information Regarding Service or PartsQUÉ Hacer SI Detecta Olor a GAS Calentador Infrarrojo a GAS Para TallerIntoxicación por monóxido de carbono AdvertenciasAviso ÍndiceCapítulo Introducción EquipoFinalidad DEL Equipo Advertencias Información General Tabla 2. Dimensiones del calentador y tamaños de orificioTabla 1. Índices en BTU y presiones de suministro Número Tema relacionadoInformación Y Requisitos Generales DE Instalación Capítulo Instalación DEL CalentadorInstrucciones DE Montaje DEL Calentador Requisitos para el suministro de gas Conexión DEL Calentador AL Suministro DE GASRequisitos relativos a los conductos Instalación de conductosUSE UNA Cantidad Moderada DE Sellador Para Conductos Figura 7. Instalación característica de los conductos Encendido DEL CalentadorCapítulo Instrucciones DE Funcionamiento DEL Calentador Instrucciones DE Funcionamiento SeguroNota Nota Capítulo Instrucciones DE Mantenimiento Para EL OperadorApagado DEL Calentador Reparación DE AveríasFigura 11. Ajuste correcto de la llama Ajuste DE LA Llama DEL PilotoSíntomas Causas Soluciones Cambio DE LA Unidad DE LA Válvula DE GASFrecuencia DE LOS Controles DEL Operador No Devuelva EL Artefacto a LA Tienda SI Debe RepararloCapítulo Lista DE Repuestos Advertencia Instruccionesde Funcionamientoy Manualdel UsuarioPara Obtener Información Sobre Reparación O Repuestos Para Obtener MÁS InformaciónEN Présence D’UNE Odeur DE GAZ Radiateur D’ATELIER À Infrarouge Alimenté AU GAZEmpoisonnement au monoxyde de carbone AvertissementsMise EN Garde Table DES MatièresChapitre Introduction ÉquipementUtilisation DE L’ÉQUIPEMENT Avertissements Tableau 2. Dimensions du radiateur et tailles des orifices Renseignements GénérauxTableau 1. Puissances en BTU et pressions d’alimentation Chapitre Installation DU Radiateur LE Réflecteur Latéral DU Radiateur Doit Être HorizontalPuissance Instructions DE Montage DU Radiateur Directives de montage du radiateur Connexion DU Radiateur À L’ALIMENTATION EN GAZ Installation des tuyauxExigences relatives à l’alimentation en gaz Exigences relatives à la tuyauterieCm 3 po Installation type de la TuyauterieConsignes DE Sécurité Chapitre RadiateurAllumage de la veilleuse Arrêt DU RadiateurDépannage Chapitre Directives D’ENTRETIEN ’INTENTION DE L’UTILISATEURRéglage DE LA Flamme DE LA Veilleuse Réglage AP Proprié DE LA 10 À 13 Millimètres FlammeSymptômes Causes Solutions Remplacement DE LA Soupape DE GAZFréquence DES Inspections PAR L’UTILISATEUR NE Retournez PAS CET Appareil À Votre Magasin SI UNE Réparation EST Nécessaire’ARTICLE DE Nomen Description Clature Informations SUR LA Commande DE Pièces

HS25NG/LP, MH25NG/LP specifications

The Mr. Heater HS25NG/LP and MH25NG/LP are reliable and efficient heating solutions designed for both residential and commercial spaces. These powerful units deliver warmth and comfort, making them ideal for garages, workshops, and outdoor settings.

One of the standout features of the HS25NG and MH25NG is their versatility in fuel options. The HS25NG is designed to use natural gas, while the MH25NG operates on propane, providing flexibility based on user needs and availability. This adaptability allows users to select the most convenient and cost-effective energy source for their heating requirements.

Both models are equipped with a robust heat output, with the capability to deliver 25,000 BTUs per hour. This level of performance ensures quick heating even in larger spaces, establishing a comfortable environment in minimal time. The units also feature a wide heating area that can efficiently cover spaces up to 600 square feet, making them suited for various applications.

User safety and efficiency are paramount in the design of these heaters. The HS25NG and MH25NG come with an automatic shutoff system that activates if the unit tips over or detects any obstruction to airflow. Additionally, they are equipped with a built-in piezo ignition system, enabling easy and reliable lighting without the need for matches or an external ignition source.

The heaters also incorporate advanced technology to optimize performance. Their infrared heating design allows for direct and efficient warmth, minimizing energy loss and ensuring that heat is directed where it's needed most. This not only enhances efficiency but can also lead to reduced energy costs over time.

Both models are designed with portability in mind, featuring a lightweight construction and convenient carry handle, making it simple to move the unit from one location to another as needed. The durable construction ensures that they can withstand the rigors of frequent use, whether it be in a workshop or an outdoor gathering.

In summary, the Mr. Heater HS25NG/LP and MH25NG/LP are powerful, versatile, and reliable heating solutions that combine advanced technology with user-friendly features. With their strong heat output, safety features, and option for both natural gas and propane, these heaters are an excellent choice for those looking for efficient heating in any environment.