Samsung SSA-R2010/EXP manual Wiegand Data Output Connection

Page 15

Output Connection

Authentication Success (orange with black stripes)

Authentication Error (orange)

INSTALLATION

DATA1 (white)

CONTROLLER

DATA0 (green)

12V (red)

GND (black)

POWER

- Wiegand DATA Output Connection

1.Connect the green line (Wiegand DATA 0) of the product to Wiegand DATA 0 of the controller.

2.Connect the white line (Wiegand DATA 1) of the product to Wiegand DATA 1 of the controller.

3.The product should be connected to GND(-) of the controller.

- Connection of Authentication Error Signal

Connect the orange line (authentication error signal) of the product to the input port of the controller.

With the I/O settings, the controller can transfer the authentication error event to the operating software program. Furthermore, you can handle various situations according to the I/O settings of the controller.

- Connection of Authentication Success Signal

Connect the orange line with black stripes (authentication success signal) of the product to the corresponding input port of the controller.

With the I/O settings, the controller can transfer the authentication success event to the operating software program.

Furthermore, you can handle various situations according to the I/O settings of the controller.

AND EXTERNAL CONNECTION

English _ 15

Image 15
Contents Please visit our website Biometric ReaderSafety information Safety informationThis device may not cause harmful interference, Important Safety InstructionsContents Product introduction FeaturesWHAT’S Included Cables Quick Guide CD ManualMaster Card Ferrite Cores X AT a Glance Front PanelDisplays the status of the system operation Rear Panel Cable Color Scheme Pins Signal Cable ColorCable Selection Termination Resistor Installing the Wall MountHost PC EARTH-GROUNDING the Communication CablesConnection Overall Wiring DiagramConnection of External LED control PowerInput Connection ControllerWiegand Data Output Connection Output ConnectionExternal Reader Connection Connecting to the External ReaderRS-485 Communication Port Connection Standalone Communication Line ConnectionRS-485 Communication Port Connection Multiple Units Hub Host PC RJ45 RJ45 RJ45 TCP/IP Communication Port ConnectionMaster ID Initializing the System Using the DIP SwitchRefer to Communication Address Setup. on InitializationRegistration Mode Reader ModeDisplay and Operation Status of READER/REGISTER To REGISTER/DELETE the Master ID Card Communication Address SetupReader Mode and Authentication If the card is not registeredPresent the registered card to the reader User management Registering the IDTo Register the ID Card Along with the Fingerprint Successfully To Delete IDData Type 26-bit /34-bit Wiegand Output DefaultTiming Diagram Output formatOther information HOW to Register the FingerprintTroubleshooting TroubleshootingProblem Action Problem Product specifications Product SpecificationsCorrect disposal of batteries in this product